23 

faucet, allowing a slow flow of water.  It may take several minutes for the flow of water to 

arrive as the media tank will be slowly filling with water.  During this time, air will escape from 

the faucet.  It is normal for the water to be highly discolored at this stage as carbon fines are 

purged from the system.  Continue until all air is purged.  Then, turn off the faucet and allow 

the media to soak for a minimum of twenty-four (24) hours.  Set the bypass valve on the 

ecoPLUS™ filter to the “bypass” position so you can use water during the media pre-soak 

process.  Run the nearby faucet until the water runs clear.

 

 

It is now safe to turn the electricity back on to your water heater. 

 

Final Media Rinse 

After the media has soaked for at least twenty-four (24) hours

, set the bypass valve on the 

ecoPLUS™ system to the “service” position again and open a nearby faucet and allow a slow 

flow of water to run for 5 minutes.  Thereafter, gradually increase the flow rate until a 

moderate flow of water is achieved and run at this level for at least another 10 minutes.  It is 

normal for the water to be discolored at this stage as carbon fines are purged from the 

system.  Gradually increase the flow rate a little more and run the water until it is completely 

clear.  If you notice a significant decline in flow rate to the faucet at any point in the process, 

shut the water off and wait 10 minutes, then resume the process where you left off.   

 

Step 17 – System Disinfection 

 

Place the ecoPLUS™ and ecoTAC™ bypass valves in the “bypass” position.  Follow the 

instructions in the 

Viqua UVMax D4 Premium Owner’s Manual Section 3.2 “Disinfection 

Procedure”

 to disinfect the UV sterilizer and downstream plumbing.  When completed, set 

the bypass valve on the ecoPlus™ and ecoTAC™ systems to the “service” position. 

 

Familiarize yourself with the UV control panel functions by reading 

Viqua UVMax D4 

Premium Owner’s Manual Section 4.

    

 

Congratulations!   

Your system is now ready to provide treated water to your home! 

 

We recommend that you limit the use of high flow rate applications for the first few days of 

operation to allow your carbon media to be fully conditioned and saturated.  It is common 

and normal for some carbon dust to be released from the filter in the first few days of 

operation.  This carbon is harmless and will generally go away within about a week. 

 

Summary of Contents for EP-600-ULT

Page 1: ...TION GUIDE ecoPLUS EP 600 ULT PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION FAILURE TO FOLLOW THESE INSTRUCTIONS MAY AFFECT THE PERFORMANCE OF YOUR SYSTEM VOID YOUR WARRANTY AND RES...

Page 2: ...amaging effects of these contaminants Our ecoTAC hard water conditioners use a salt free water treatment technology called Template Assisted Crystalization or TAC for short to prevent hard water scale...

Page 3: ...p 8 Connect the Inlet Assembly to the Housing Cap 15 Step 9 Connect the Bypass to the Inlet Assembly 16 Step 10 Connect the ecoPLUS Tank to the Inlet Assembly 16 Step 11 Connect Bridge Assembly to the...

Page 4: ...avy components without assistance if you are not physically capable of safely carrying out the procedure If the water treatment system is to be left unattended for an extended period of time vacation...

Page 5: ...SYSTEM DAMAGE INCLUDING WATER LEAKS AND CORRESPONDING PROPERTY DAMAGE AND MAY VOID YOUR WARRANTY It is very important to note that the presence of elevated levels of chlorine iron manganese hydrogen...

Page 6: ...hstand pressures exceeding 90 PSI if your water pressure is greater than 70 PSI we recommend that you have a certified plumber install a pressure reducing valve ahead of the ecoPLUS system The system...

Page 7: ...INIMIZE ANY PROBLEMS WITH COPPER AVOID APPLYING EXCESS FLUX ON THE INNER SURFACES OF THE PIPE AND USE A LOW CORROSIVITY WATER SOLUBLE FLUX LISTED UNDER THE ASTM B813 STANDARD FOR HOMES WITH SIGNIFICAN...

Page 8: ...8 Step 1 Pre Installation Inspection...

Page 9: ...Steel Connectors 1 Quick Connect to 1 NPT 8 Outlet Assembly 9 Inlet Assembly 10 Spanner Wrench 11 Small Parts Bag 8 Lag Bolts and 8 Washers 12 ecoTAC Media Tank and Valve Head 13 Bridge Assembly 14 UV...

Page 10: ...n space required for this model is 40 Wide x 63 High x 20 5 Deep In most cases the system should be installed after the branch line s to exterior irrigation unless you want your exterior faucets to de...

Page 11: ...tach the cartridge filter housing cap and mounting bracket to your wall using the remaining four 4 lag bolts and washers as shown below The top of the mounting bracket should be mounted EXACTLY 52 3 4...

Page 12: ...nsuring that it is securely screwed into the wall studs When the cartridge filter housing is full of water it is heavy so it is important to ensure that the mounting will be strong enough to support t...

Page 13: ...sump containing the filter cartridge onto the cartridge filter housing cap Hand tighten only do not use the spanner wrench Do not over tighten Excessive force is not required to obtain a good seal Ste...

Page 14: ...he treatment tank This is completely normal and is necessary to allow the required freeboard to permit the media bed to completely fluidize during operation When water begins to flow into the bottom o...

Page 15: ...Cap Refer to John Guest Quick Connect Style Fittings above First ensure the John Guest fitting is unlocked Then push the elbow end of the inlet assembly on to the black stem adapter as far as it will...

Page 16: ...hed to the rest of the tank If your tank appears to be crooked the base has likely been knocked out of alignment during shipping This can be correct by picking the tank up and tapping it on a hard sur...

Page 17: ...17 go to next page...

Page 18: ...S treatment tank The black base of the media tank is not permanently attached to the rest of the tank If your tank appears to be crooked the base has likely been knocked out of alignment during shippi...

Page 19: ...btain a good seal The other end 3 4 steel of the flexible connector attaches to the inlet bottom port on the UV disinfection chamber in the same manner The flexible connector can be bent to reach the...

Page 20: ...drain as much water out of the plumbing system as possible Following completion of the entire installation restore the water flow by turning on the household main water valve and allow all air to be p...

Page 21: ...r incoming water line It is designed to be bent a many times but not repeatedly over and over Doing so may reduce the structural integrity of the fitting Alternatively you can make the plumbing connec...

Page 22: ...sulted from the installation Once the water is running clear and free of air close the water tap INSPECT ALL PLUMBING CONNECTIONS AND THE INTERFACE BETWEEN THE MEDIA TANK AND ITS VALVE HEAD FOR LEAKS...

Page 23: ...mal for the water to be discolored at this stage as carbon fines are purged from the system Gradually increase the flow rate a little more and run the water until it is completely clear If you notice...

Page 24: ...bottom drain valve on the hot water heater 30 to 60 days after installation of ecoTAC Be sure to turn off the electricity to your water heater before draining your tank Follow the manufacturer s inst...

Page 25: ...sily wiped down because they can no longer adhere to the sides of the shower TROUBLESHOOTING Problem Solution Reduced water pressure and or flow rate after initial installation Limit high flow rate de...

Page 26: ...ER AT SEVERAL FAUCETS Cleaning The outside of your system including cartridge filter housing and media tank can be washed with a mild soap and water if desired Do NOT use strong cleaners as they may c...

Page 27: ...ot be stopped Put the O ring in a safe place where it will not get dirty or otherwise contaminated Replacement O Ring Pentek Buna N Big Blue O Ring 151122 4 Take out the used filter cartridge and disc...

Page 28: ...our ecoTAC hard water conditioner this may need to be done every few months If you have soft water or you have treatment for your hard water problem sleeve cleaning is generally only required once per...

Page 29: ...lytic Activated Carbons Calgon Carbon Corporation Moon Township PA USA Made in USA NSF ANSI Standard 61 KDF 55 Process Media KDF Fluid Treatment Inc Three Rivers MI USA Made in USA NSF ANSI Standard 4...

Page 30: ...comprehensive warranty program including Limited Lifetime Warranty on major components Major components including the cartridge filter housing media tank s riser tube s upper media screen s and tank...

Page 31: ...This warranty applies only in Canada and the United States of America In the event that a part is deemed defective the user must immediately inform HomePlus Products Inc who will furnish a replacemen...

Page 32: ...xceed the actual purchase price paid by the authorized distributor or consumer for the product In no event shall HomePlus Products Inc be liable to the distributor or any other person or entity for sp...

Reviews: