13.14
Bottom Feed In-Parallel Split Arrays (For Multi-Level Split Arrays)
An “in parallel”
configuration is recommended for installing two different arrays on any
differing or similar levels. For split flow multi-level arrays at substantially different
heights (>1m), a ball valve constriction MUST be installed to limit flow to the collector
array installed at the lower level.