Page 8
OMNI by EconoHeat
Wiring
Figure 2 –
Wiring Diagram
1. Wire 120V into main electrical box mounted on burner backside of heater cabinet with
separate circuit
20-amp protection using 12-gauge wire.
Connect power line to black
wire and all whites (NEUTRAL or COMMON) together.
IMPORTANT
, Connect ground wire to
ground mounting point in main junction box (green screw).
2. Connect wires from main junction box to remote oil pump power, yellow to yellow and
neutral common white to white.
3. Wire low voltage thermostat into “T” marked terminals on oil primary control on burner (Box
on burner gun assembly with red reset button – igure 3).
Ducting
All unit heaters are designed with a condenser-type pressure propeller fan for air deliver, and
have been successfully ield ducted (see speciications). Call factory for further assistance if
needed.
240 V