The following tests and measures must be carried out during regular maintenance.
10.1.1 Battery replacement
•
Remove the screws (1) at the head.
•
Remove lamp head from the enclosure.
•
Pull the connection lines (A1, A2) off the charging contacts (B1, B2).
•
Pull the connection lines (2) off the battery contacts.
•
Remove the screws (3) from the retaining bracket.
•
Remove the battery retaining bracket (4).
•
Remove battery (5) from the enclosure.
•
Insert new battery into enclosure according to marking.
•
Insert battery retaining bracket (4).
•
Screw down the battery retaining bracket with the screws (3) -
tightening torque 0.5 Nm.
Check
Measures
the permissible ambient temperature
If exceeding the permissible ambient
temperature or falling below the device
must be taken out of operation.
the enclosure components for formation of
cracks and damage.
Replace the exchangeable enclosure
components. If the enclosure components
are non-exchangeable, the device must be
taken out of operation.
its intended use
If the device is not used according to its
intended use, it must be taken out of
operation.
WARNING
Danger when used in hazardous areas!
The explosion protection is impaired!
•
Open the portable lamp in safe areas only.
15005E00
1 6 screws for head (Torx 10)
A1 PCB connection line
2 PCB connection line (+; -)
A2 PCB connection line
3 2 screws for retaining bracket (Torx 10) B1 Charging contact connection line
4 Battery retaining bracket
B2 Charging contact connection line
5 Battery
-
+
+
-