24
www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206
B. Replace the top UV1 lamp
1
Switch the power OFF and
unplug Appliance
(Figure 13, page 20).
2
Wait for 10 minutes to allow the UV to cool down.
3
Remove the screws at the back of the top cover and
put them in a secure location
.
Remove the cover (Figure 21). 1st time replacement requires cutting security tape.
(Figure 28)
4
Remove the screws securing the lamp (Figure 22).
5
Disconnect UV connection wire (Figure 23).
6
Pull gently on wires to release silicone plug and remove the UV bulb (Figure 23).
7
Replace with new bulb.
8
Reassemble parts in reverse order and close cover.
9
Plug in the Appliance and
turn the power ON
( Figure 13, page 20).
Figure 20
Figure 21
Figure 22
Figure 23
C. Replace the cool water out UV2 lamp
1
Switch the power OFF and
unplug Appliance
(Figure 17, Page 20).
2
Wait for 10 minutes to allow the UV to cool down.
3
Remove the screws at the back of the top cover and
put them in a secure location
.
Remove the cover (Figure 22 and 23, page 20).