background image

24

www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206

B. Replace the top UV1 lamp 

Switch the power OFF and 

unplug Appliance

 (Figure 13, page 20). 

Wait for 10 minutes to allow the UV to cool down. 

Remove the screws at the back of the top cover and 

put them in a secure location

Remove the cover (Figure 21).  1st time replacement requires cutting security tape.           

(Figure 28)

Remove the screws securing the lamp (Figure 22). 

Disconnect UV connection wire (Figure 23).   

Pull gently on wires to release silicone plug and remove the UV bulb (Figure 23). 

Replace with new bulb. 

Reassemble parts in reverse order and close cover.  

Plug in the Appliance and 

turn the power ON 

( Figure 13, page 20).

Figure 20

Figure 21  

Figure 22

Figure 23   

C. Replace the cool water out UV2 lamp  

Switch the power OFF and 

unplug Appliance

 (Figure 17, Page 20).  

Wait for 10 minutes to allow the UV to cool down. 

Remove the screws at the back of the top cover and 

put them in a secure location

Remove the cover (Figure 22 and 23, page 20). 

Summary of Contents for 30 Series

Page 1: ...1 www EcoloBlue com 800 691 6043 1 925 231 0206 EcoloBlue 30 Series Atmospheric Water Generator ...

Page 2: ... Model 30 Series 11 Additional Display Options and Settings 12 SET UP 14 Preparation and Location 14 INSTALLATION CHECKLIST 15 Reverse Osmosis Filter Installation 16 Cleaning 17 Flushing the System 17 Optional Connection to Municipal City Water 18 OPERATION 20 Turning Generator ON OFF 20 Dispensing water 20 Heating and Cooling Water 20 MAINTENANCE 21 Parts Replacement 22 A To replace a filter 22 B...

Page 3: ...AL FILTER 37 TECHNICAL SPECIFICATIONS 39 MAINTENANCE LOG 40 NOTICE The EcoloBlue Life Energy Atmospheric Water Generator 30 Series is intended for INDOOR USE ONLY in homes or small office 3109 Grand Avenue Suite 423 Miami Florida 33133 5702 Marsh Drive Unit K Pacheco California 94553 800 691 6043 Outside U S 1 925 231 0206 Technical Support 9 00 a m 5 00 p m Pacific Time M F www EcoloBlue com E ma...

Page 4: ...ance using the latest technology available to the industry EcoloBlue designed your Atmospheric Water Generator with one objective in mind produce the maximum amount of high quality drinking water using only a minimum amount of electricity In addition to atmospheric water production the Appliance can also be used as a conventional water purifier by connecting it to an external municipal city water ...

Page 5: ...our unit Do not connect the Water Generator to a circuit operating other high pow er consuming Appliances such as a toaster hot plate or refrigerator Avoid prolonged direct eye exposure to the ultraviolet UV devices in this Appliance as UV light can damage the eye Do not look at the bulb WARNING Do not insert or unplug the power cord with wet hands or while in contact with another grounded device ...

Page 6: ... be fitted by the owner with a cover Avoid exposing the unit to direct sunlight If the ambient temperature of the installation location is anticipated to fall below 32 F 0 C be certain to completely drain all water and unplug the Appliance in order to prevent damage to the Appliance caused by freezing Similarly empty and unplug the Water Generator if it will not be used for 5 FIVE or more consecut...

Page 7: ...mitations or exclusions on the du ration of an implied warranty of merchantability or fitness In such locations the above limitations or exclusions may not apply to you If this product fails to perform as warranted customers sole and exclusive remedy shall be repair or replacement according to the terms of the limited warranty of EcoloBlue Inc EcoloBlue Inc does not assume any responsibility or li...

Page 8: ...ing water produced the Atmo spheric Water Generator utilizes multiple filtration technologies see below When the air is dry and cold water generation may become slow and inefficient It is recommended that the Appliance be connected to a municipal water supply allowing the Appliance to serve as a water purifier using its filtration system Key features of the Atmospheric Water Generator Energy Savin...

Page 9: ...olecular Sieve Faucet Filters The Nozzle is equipped with two molecular sieves screens to trap any fine particles that may be suspended in the water Components of the Atmospheric Water Generator Refer to Figures 1 and 2 for more information Novel and Attractive Cabinet Style The EcoloBlue Atmospheric Water Generator has a smaller and sleeker design compared to other Gen erators on the market The u...

Page 10: ...ater production efficiency Electrostatic Air Filters The electrostatic air filters effectively prevents micro particles and dust from entering the Appliance as well as deterring formation of bacterial and fungal growth introduced to the Appliance by the outside environment Overheat Protector In the event that the hot water tank overheats during the heating process the overheat protector will autom...

Page 11: ...10 www EcoloBlue com 800 691 6043 1 925 231 0206 Figure 2 ...

Page 12: ...shing the water generation is off When icon stays on no flashing the generation is on but water is not generating 1 UV1 Warning Icon This icon will flash when the UV1 light needs replacement This icon will light when the UV1 is on 2 UV2 Warning Icon This icon will flash when the UV2 light needs replacement This icon will light when the UV2 is on 3 UV3 Warning Icon This icon will flash when the UV3...

Page 13: ...change the MINUTE by pressing SET button 4 Displays END TIME for pre set automatic water generation Press SET but ton until hour flashes To change the HOUR press SET button Switch to MINUTE by pressing the MODE button and change the MINUTE by pressing SET button 5 W ON water generation function ON W OFF water generation function OFF 6 H ON heating function is ON H OFF heating function is OFF 7 C O...

Page 14: ...691 6043 1 925 231 0206 8 Press and hold to start up or shut down the Appliance 9 5 Press and hold HOT button to dispense hot water 18 Press and hold COLD button to dispense the cold water Press and hold LOCK button after beep ...

Page 15: ...iance in a standing position to make sure all refrigerant drains to the compressor Immediately connecting the Appliance to its power source after un packing may damage the compressor and void its warranty The power cord plug must be inserted into an electrical outlet rated to deliver no less than 10 Amperes continuous Check the panel box breaker rating for the outlet serving the unit Consult a lic...

Page 16: ...LIST Unpack the unit from its packaging Confirm all the parts are there Refer to Figures 1 and 2 Place the unit in desired location Lock brake levers Install Reverse Osmosis Filter Clean the bottom storage tank Flush the system Connect to Municipal City Water optional ...

Page 17: ...the foam packaging as described below 2 Open the bottom front panel of the Appliance by carefully opening the front panel from the left Figure 3 3 Locate the empty filter space Figure 4 4 Gently pull filter cap towards you Figure 5 5 Remove the RO filter from the packaging 6 Install the RO Filter in the proper orientation Figure 6 8 7 Close the front panel Figure 3 Figure 4 Remove RO filter from p...

Page 18: ...pletes to a level 2 3 MAKE SURE TO TURN OFF THE APPLIANCE EVERYTIME YOU FILL THE BOTTOM TANK OR IT MIGHT RESULT IN A LEAK WARNING Overfilling the bottom tank also might result in a leak triggering the leak detector 4 Turn the power OFF by pressing and holding POWER button 5 Drain water from the rear HOT Water Drain outlet The HOT Water drain has a screw cap and a rubber plug please remove both Whe...

Page 19: ...ee Connector Secure with the enclosed wrench 4 Place thread tape on the threads of the Appliance s Input Valve and then connect the valve to threaded Tee Connector Secure with the enclosed wrench 5 Cut the water tube to the length needed for your application 6 Remove the nut from the Input Valve 7 Slide the nut over the water tube so that the threads face the end of the tube 8 Place pipe tape on t...

Page 20: ...19 www EcoloBlue com 800 691 6043 1 925 231 0206 Figure 9 Figure 11 Figure 12 Figure 10 Plastic Sleeve Plastic Nut Tee Connector Water Tube Nut Input Valve Plug ...

Page 21: ...then press and HOLD the HOT button to dispense the desired hot water NOTE When humidity is low water generation will be slow Tap water can be poured directly into col lection tank or the municipal water kit will allow direct connection to the available water source Heating and Cooling Water The Appliance maintains the cold water while offering hot water as needed To turn the cooling and heating of...

Page 22: ... the Generator it is recommended that you dispense at least 3 liters 75 gal of water every day 3 If hot water is not dispensed for a prolonged period it is recommended to turn on the heating process for not less than 30 minutes once a week Press and hold the LOCK button until you hear a beep and the button HOT flashes and press the HOT button to release 500 ml of hot water from the faucet 4 If the...

Page 23: ...water usage rates require less frequent filter replacement Local air and water quality will also impact the filter replacement schedule Parts should be replaced at least as often as the required replacement listed above A To replace a front filter Be advised that the water in the filters are under pressure and may spray out slightly when discon nected We strongly recommend replacing filters one by...

Page 24: ...23 www EcoloBlue com 800 691 6043 1 925 231 0206 Each filter is changed in the same manner Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 ...

Page 25: ... lamp Figure 22 5 Disconnect UV connection wire Figure 23 6 Pull gently on wires to release silicone plug and remove the UV bulb Figure 23 7 Replace with new bulb 8 Reassemble parts in reverse order and close cover 9 Plug in the Appliance and turn the power ON Figure 13 page 20 Figure 20 Figure 21 Figure 22 Figure 23 C Replace the cool water out UV2 lamp 1 Switch the power OFF and unplug Appliance...

Page 26: ...connection wire Figure 26 7 Remove the UV bulb Figure 27 8 Replace with a new bulb 9 Replace all parts in reverse order 10 Plug in the Appliance and turn the power ON Figure 13 page 20 Figure 24 Figure 25 Figure 26 Figure 27 Figure 28 Please NOTE For 1st Time UV Bulb replacement it is necessary to cut the seal to separate the top of the Styrofoam container ...

Page 27: ...utes to allow the to cool down 3 Remove the bottom tank Figure 29 4 Remove the screws securing the lamp Figure 30 5 Disconnect UV connection wire Figure 31 6 Pull gently on wires to release silicone plug and remove the UV bulb Figure 32 7 Replace with new bulb 8 Plug in the Appliance and turn the power ON Figure 13 page 20 Figure 29 Figure 30 Figure 31 Figure 32 ...

Page 28: ...ording to the air quality conditions in your area Before starting wash hands thoroughly and wear latex or other similar disposable gloves Figure 33 Figure 34 To Clean Filter B 1 Switch the power OFF and unplug Appliance shown in Figure 13 page 20 2 Pull out the air filter cover Figure 35 3 Open the air filter cover and remove the air filter Figure 36 4 Rinse in clean cold water to remove dirt Gent...

Page 29: ... remove screws as shown in Figures 38 through 39 3 Rinse in clean cold water to remove dirt Gently press out the water and then holding with the fingers of one hand ta filter over a sink to shake off the remaining water 4 Straighten and replace the filter into its holder in the Generator 5 Plug in the Appliance and turn the power ON Figure 13 page 20 Figure 38 Figure 39 Figure 40 ...

Page 30: ...ttom tank at least once a month 1 Switch the power OFF and unplug Appliance Figure 13 page 20 2 3 4 5 6 7 8 9 Take out bottom tank Figure 41 Open tank cover Figure 42 Remove filter cup by lifting the handle Figure 43 Squeeze filter basket handles and take out filter mesh cover A and fabric B Figure 45 Rinse the filter cup with clean cold water Figure 46 Rinse the bottom tank with water and wipe dr...

Page 31: ...30 www EcoloBlue com 800 691 6043 1 925 231 0206 Figure 43 Figure 44 Figure 45 Figure 46 Figure 47 ...

Page 32: ...about 0 5 Liters 13 gal of the solution from the hot water drain outlet in the back The HOT Water drain has a screw cap and a rubber plug please remove both When draining complete replace plug and cap 12 Plug in the Appliance and turn the power ON 13 Keep the remaining solution soaking in the top tank for at least 2 additional hours Figure 60 14 After 2 hours Dispense 2 liters 5 gal of solution fr...

Page 33: ... page 20 2 Add approximately 8 oz of peroxide to bottom tank 3 Add water to fill bottom tank 4 DO NOT turn machine on 5 Let soak for 2 hours Drain solution rinse with tap water and wipe out tank 6 Plug in the Appliance and turn the power ON to begin water generation Figure 48 Figure 50 Figure 52 Figure 49 Figure 51 Figure 53 ...

Page 34: ...nject with CO2 Press the soda button for 1 3 seconds repeat to increase carbonation Figure 10 7 IMPORTANT You must tilt the bottle forward when finished adding the CO2 it will slowly release pressure and hisses before unscrewing the bottle completely Once the hissing sound ends the bottle can be removed Figure 11 8 To maintain carbonation please screw the bottle cap tightly Press to release door A...

Page 35: ...34 www EcoloBlue com 800 691 6043 1 925 231 0206 Figure 9 Figure 10 Figure 11 ...

Page 36: ...ed Power Cord Troubleshooting The Appliance does not work even after the power cord is plugged in Check the circuit breaker in the facility and test with another device to assure the outlet is live Check to ensure the voltage being delivered to the outlet is in the correct operating range for the device Make certain that the plug connection to the wall outlet is tight and secure and the cable is n...

Page 37: ...e hoses housed in black foam to release any blockage No hot or cool water output ambient temper ature water only The heating function will be activated only when the top tank water level on the screen is a level two or higher The cooling function will be activated only when the top tank water level on the screen is a level three or higher Make sure the Appliance operating temperature level is in t...

Page 38: ...alified and properly trained service technician to examine the Appliance and perform necessary repair procedures Contact EcoloBlue or your local distributor for service assistance The manufacturer will not bear any responsibility for damages to the Generator damage to the owner s property or personal injury sus tained during attempts at self repair User repairs to the Appliance not specifically re...

Page 39: ...ue 30 Series in a commercial establishment may constitute a violation by the commercial owner or tenant of a state or municipal electrical code for which EcoloBlue Life Energy disclaims any and all liability Note EcoloBlue reserves the right to make changes amendments deletions revisions and or varia tions in and to EcoloBlue Atmospheric Water Generator and in and to the contents of this manual at...

Page 40: ... 925 231 0206 TECHNICAL SPECIFICATIONS EcoloBlue 30s U S Patent No 7 861 544 EcoloBlue Utility China Patent No ZL 201220091481 8 EcoloBlue Utility China Patent No ZL 200910205962 x EcoloBlue Invention Patent No CN101731714 RoHS COMPLIANT ...

Page 41: ...231 0206 Date EF1 Filter EF2 Filter EF3 Filter Mineral Filter Air Filter Fabric Nanometer Filtration Faucet Reverse Osmosis Filter Air Filter Replace Inline UV Lamp Replace Top Tank UV Lamp Replace Bottom Tank UV Lamp Comments MAINTENANCE LOG ...

Page 42: ...gain Group Complex 8 Xihua Road Wuxi New Wuxi District Jiangsu Province P R China 214028 ECOLOBLUE USA East Coast 3109 Grand Avenue 423 Miami FL 33133 USA West Coast 5702 Marsh Drive Unit K Pacheco CA 94553 E info EcoloBlue com www EcoloBlue com Sales Tech Support M F T 800 691 6043 T 925 231 0206 9 00 am 5 00 pm PT 9 00 am 8 00 pm ET ECOLOBLUE SUZHOU LTD Wellgain Group Complex 8 Xihua Road Wuxi N...

Reviews: