background image

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

© 2015 Ecolink Intelligent Technology Inc. 

 

 

 

 

 

 

 

 

 

 

 

 

 

PN PIR-ZWAVE2  R1.04 

 

 

 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

 

   
 

 

 

 

 

 

 

 

 

Adjusting the Sensitivity of the Motion Sensor

 

The motion sensor has sensitivity adjustment via jumper placement on a pair of pins on 
the circuit board of the sensor.  Refer to the battery replacement section to open the 
case and find the jumper pins inside the case. 

 

 

Test Mode

 

The amount of time it takes for the sensor to reset after motion has been detected can be 
shortened for quicker motion sensor testing.  To enter test mode remove the cover from the 
sensor.  Find the pair of metal pins on the lower right hand side of the circuit board labeled 
“TEST”.  Connect these two pins together using the provided jumper.  Replace the sensor 
cover.  After approximately ten seconds the red LED will go out.  The sensor is now in test 
mode.  In test mode the LED will flash once when motion is detected and again when motion 
detector is ready again.  In this mode you can wave your hand in front of the sensor or walk 
around the room and see where motion is detected.  Note that there must be a length of 
time without motion before motion detect is enabled again.  To restore normal operation, 
simply remove the test jumper and replace the sensor cover. 

Summary of Contents for PIR-ZWAVE2

Page 1: ...r see detection region diagram Battery type 3V Lithium CR123A Battery life approximately 3 years Passive Infrared PIR based technology Network Inclusion The sensor must be added to a Z Wave network prior to use To include the sensor in a network both the sensor and the network controller must be in inclusion mode at the same time Refer to the instructions provided by the manufacturer of your speci...

Page 2: ...n refer to the Test Mode section of these instructions Network Inclusion Key Points to Remember Controller inclusion mode must be activated BEFORE starting sensor inclusion mode The sensor can only be included into one controller network at a time and must be excluded from one network before inclusion in another Removing the pull tab connects the battery and initiates sensor inclusion mode Inclusi...

Page 3: ...bracket 4x screws 2x jumper 1x battery 3x pieces of adhesive tape STEP ONE Mount bracket to wall First attach the sensor mounting bracket to the wall using either adhesive tape OR screws optional For best performance mount the bracket 6 5 to 7 5 feet above the floor 2 to 2 3 meters Corner Mount Flush Mount Adhesive Bracket Screws Optional ...

Page 4: ...e bracket orientation The large clip that holds the case together is located on the TOP Please be advised that adhesive tape may damage the surfaces to which it is attached and then removed from The sensor slides onto the bracket until the tab engages and CLICKS The distribution pattern of the motion detector is approximately 50 degrees left and right of center and at maximum sensitivity will reac...

Page 5: ...ove the cover from the sensor Find the pair of metal pins on the lower right hand side of the circuit board labeled TEST Connect these two pins together using the provided jumper Replace the sensor cover After approximately ten seconds the red LED will go out The sensor is now in test mode In test mode the LED will flash once when motion is detected and again when motion detector is ready again In...

Page 6: ...esh increasing range and redundancy For a more complete look at Z Wave technology for non technologists and to learn more about Z Wave s role as a key enabling technology for the Internet of Things and connected objects please visit www z wave com Z Wave Device Class and Command Class Information This Z Wave sensor is a Z Wave generic Device Class of GENERIC_TYPE_SENSOR_NOTIFICATION and a specific...

Page 7: ...ow battery notifications and sensor binary reports Group 2 is intended for devices that are to be controlled i e turned on or off on only by default with a Basic Set On inclusion the controller should put its node ID in group 1 but not group 2 Network Wide Inclusion This sensor also supports Network Wide Inclusion such that the Sensor can be included into the Z Wave network over the mesh network a...

Page 8: ...he sensor will wake up every so often and when the case is closed to send a Wake Up Notification to allow the life line master node controller that the sensor is now available for any queued messages that the controller may have for the sensor The time between Wake Up Notifications can be configured with the Wake Up Notification command class to be between 1 hour and 1 week with interval steps of ...

Page 9: ...y Inc could void the user s authority to operate the equipment This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device C et appareil est conforme la norme d Industrie Cana...

Page 10: ... 2015 Ecolink Intelligent Technology Inc PN PIR ZWAVE2 R1 04 Designed in Carlsbad CA www discoverecolink com ...