12
Eng
lis
h (
EN
)
WARNING:
When opening the ball valve / pistol
after unit has stopped in Foam position,
a burst of Foam/Air/Water will come
out. This as the outlet hose is filled with
foam. The burst will disappear after 3-5
seconds, point the ball valve towards the
floor when opening.
13.3. Testing the Sanitise function:
Hold the ball valve / pistol over sink for testing.
1. Turn the selector knob on the unit to sanitise
position.
2. Connect the blue sanitise nozzle to the ball valve
/ pistol.
3. Open the ball valve / pistol and the pump will
start, it may take several seconds for the outlet
hose to be filled completely with sanitiser.
4. The unit is now sanitising.
5. Close the ball valve / pistol to stop sanitising, the
unit will automatically stop a few seconds after
the Bball valve / pistol is closed.
If all 3 tests perform correctly the unit is ready for use.
13.4. Checking the unit for leaks
1. Remove the cover by loosening the 4 screws on
both side of the unit using a 4mm Allen key.
2. Check all connections and hoses for leaks.
3. Once you have determined that there are no
leaks mount the cover again, tighten the 4
screws.
14. Service / Maintenance
instructions
WARNING:
Service / Maintenance may only be
carried out by authorized and qualified
personnel.
14.1. Recycling and scrapping
Recycle the wrapping and scrap the unit according to
recommendations from the local authorities.
15. Descaling
The following descaling interwals must be observed
to prevent lime build up in the unit, that can discon-
tinue operation of the unit
°dH
ppm
Time between Descaling
0-5
18-90
12 months
5-10
90-180
6 to 12 months
10-15 180-270
3 to 6 months
15-20 270-360
3 to 6 months
>20
>360
1 to 3 months
16. Troubleshooting
For details regarding troubleshooting see trouble-
shooting guide.
WARNING:
Service / Maintenance may only be
carried out by authorized and qualified
personnel.
Summary of Contents for XP Foamer
Page 1: ...XP Foamer Service Manual Manuel entretien Manual de servicio ...
Page 15: ...15 1 115 230 V 60 Hz 110003062 English EN 19 Pumpecurve ...
Page 16: ...16 English EN 110002801C ...
Page 17: ...Fransk Français FR ...
Page 31: ...31 1 115 230 V 60 Hz 110003062 Français FR 19 Courbe de la pompe Français FR ...
Page 32: ...32 Français FR Français FR ...
Page 33: ...Spansk Español ES ...
Page 47: ...47 1 115 230 V 60 Hz 110003062 Español ES 19 Curva de bombeo Español ES ...
Page 48: ...48 Español ES Español ES ...
Page 49: ...49 Recommended spare parts Pièces de rechange conseillées Piezas de recambio recomendadas ...
Page 50: ...50 1 2 3 6 7 5 4 8 9 10 11 13 16 14 12 15 110003058b ...
Page 52: ...52 1 17 3 2 21 19 18 5 4 7 20 15 16 11 9 14 13 9 12 10 8 110006636 110003230 ...
Page 54: ...Installation 20 20 3 3 4 GHT 10 4 Ø 0 3 17 2 4 7 4 7 17 110004860A USA 54 ...
Page 55: ......