![Ecolab MULTILINE 1000 Short Operating Instructions Download Page 21](http://html1.mh-extra.com/html/ecolab/multiline-1000/multiline-1000_short-operating-instructions_2354459021.webp)
3
Structure
3.1
Structure of the MULTILINE 1000
A
B
C
F
G
D
E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Fig. 1: Structure of the MULTILINE 1000
1
LC display
2
‘Alarm’
display (red)
Function:
Flashes, if fault is present or empty signal has been
activated. Further details in display
3
Pressure gauge
Function:
Displays tank pressure
4
Pressure adjustment control
Function:
Setting tank pressure
5
Acknowledgement key
‘ENTER’
Function:
Confirm parameters set or to interrupt application
6
Adjustment key
‘down’
Function:
Adjust application time or set parameters
7
Adjustment key
‘up’
Function:
Adjust application time or set parameters
8
Manual operation key
Function:
Manual mode is activated
9
Continuous/automatic operation change-over key
Function:
Switch between automatic / continuous modes.
The relevant LED lights up
10
‘Automatic operation’
display
Function:
Device in automatic mode
11
‘Continuous operation’
display (green)
Function:
Device in continuous mode
12 Compressed air input
13 Valve control pressure
14 Tank pressure
15 Rotor spray connection
16 Start signal connection
17 Reserve signal connection
18 Empty signal alarm connection
19 Mains switch with voltage selector and fuse
Function:
ON/OFF - selection of mains voltage (230 V or 115 V)
A
Compressed air input
B
EP valve control
C
Pressure tank
D
Rotor spray control
E
Start signal input/completed message output, Alarm
output
F
Reserve signal input
G
Empty signal input
Structure