![Ecolab Inspexx SD - Mrk. II Directions For Use Manual Download Page 17](http://html1.mh-extra.com/html/ecolab/inspexx-sd-mrk-ii/inspexx-sd-mrk-ii_directions-for-use-manual_2354477017.webp)
17
Eng
lis
h (
EN
)
11. Settings for Inspexx SD mrk. II
Flow sensor water:
IMPS: 1,0
IMPR: YES
OU1: IMP
OU2: I
RSP: 0,0
REP: 50,0
EP: HI
Controller:
User: 9030
Password: 9030
Manufactory settings:
Sensors: ON
Type; Inspexx SD 210
Min. lim: 0,05
Max. lim: 0,30
Batch level: 100 l
Pulse rate chemical: 0,5 ml
Pulse rate water: 1000 ml
Settings:
Min.: 0,12%
Max.: 0,20%
Total: Reset
Alarm: Clear all
Pump pressure out: 5 bar
Pressure switch start: 3 bar
Dosatron setting (conc.): 0,15% at display off
12. Maintenance
12.1. Instructions
a) After one month of use the Phoenix station must
be maintained by a service engineer. The functional-
ity and any possible errors should be maintained.
Furthermore, the unit must be checked for leaks.
The above maintenance should be carried out mini-
mum every third month. If required the interval might
be shorter.
b) Depending on usage, at least once a year mainte-
nance should be undertaken by an authorized service
engineer in order to prevent defects and failure of op-
eration. Authorized engineers are persons who due to
their skills and experience have sufficient knowledge
of the unit in question and are confident with the state
work safety regulations, accident preventing regula-
tions, lines and generally acknowledged technical
regulations such as DIN-norms and VDE provisions.
For your safety this cleaning unit has been manu-
factured according to all relevant regulations valid in
the EU and it has therefore been fitted with the CE
marking.
12.2. Maintenance kits
The dosing pump have some moving parts and in the
combination with detergents these parts have to be
changed during time and use. It is recommended to
make service at the pump due to working conditions
to keep it in function. O-ring in motor part and or in
dosing part should be changed during service. There
is for this pump one an o-ring kit for the motor part
and a kit for the dosing part.
For further details please see next page.
Summary of Contents for Inspexx SD - Mrk. II
Page 1: ...Inspexx SD Mrk II Directions for use Gebrauchsanweisung Mode d emploi Instrucciones de uso...
Page 2: ......
Page 56: ......
Page 58: ...English EN Layout and Parts Inspexx SD mark II 11900460 1 58 English EN...
Page 65: ...110005503 9A 110005503 10 65...
Page 66: ...English EN Mounting Inspexx SD mark II 119000460 2 66 English EN...
Page 67: ......