Safety overflow hose
CAUTION!
The safety overflow hose (PVC - hose clear; included in delivery) must be
installed. The hose may only be used for the overflow line!
1.
Shorten the PVC hose to the required length.
2.
Connect the hose to a collection container or direct it to the sewage system.
Measuring cell
NOTICE!
When defining the measuring and dispensing points in the dishwasher tank,
the flow characteristics of the cleaning fluid need to be taken into account.
The measuring point must always be located in direction of flow after the
dispensing point. The bore for the measuring cell should be located at an
angle of about 45 degrees to the bottom of the tank to prevent residue and
air bubbles building up in the bore.
The following distances must be observed:
Construction element
Spacing
Tank corners
at least 50 mm
Heating elements
as large as possible
Mounting the measuring cell:
1.
Make a sufficiently large hole at the desired location in the tank wall.
2.
Fit the measuring cell to the tank wall of the dishwasher.
Rinse aid connection
Concerns appliances with integrated rinse aid metering pump (PDRX).
1.
On the metering side, a pressure retaining valve must be installed in the rinse aid
feed of the dishwasher.
CAUTION!
Always use approved installation parts and accessories;
refer to accessories and installation list.
5.3
Connection (electrical)
Personnel:
n
Qualified electrician
Risk due to electrical energy
WARNING!
The protective earth connection is marked by this symbol at the connection
points.
Assembly and installation
17
417102610 Rev. 01-12.2020