5.2 Content of the Errors menu – CAUSE & REMEDY
Example of Error log screen display:
All error occurrences will be stamped with date and time.
E indicates Error number. P indicates Pump number.
E0\P1
2006-01-01
12:00
C1 Inverter
Error
BA
E0\P1
2006-01-01
12:00
C1 Inverter
Error
BA
The error log stores up to 1000 occurrences. When max. memory is reached, the errors will be
deleted according to ”First in” First out” principle.
5.2.1 Error List
Error
Cause
Remedy
C1 Inverter
Error
1. Frequency inverter in error state
1. Switch off the power on the service
switch. Wait 180 sec. Switch on the unit
again. If error still occurs, please contact
your local service technician.
C2 Low Supply
Pressure
1. Insufficient water supply
1. Secure sufficient water supply pres
-
sure.
2. Check inlet filter for impurities/rinse
filter
3. Contact your local service technician.
C3 High Water
Temp.
1. Water pump top temperature is above 80°
2. Water consumption is too low (pump column has
been overheated)
1. Lower the inlet water temp. (max
70°C)
2. Secure sufficient water consumption
3. Contact your local service technician.
C4 High Motor
Temp.
1. Insufficient cooling of motor
2. The ambient temperature is above 40°
1. Secure that all air channels are open
and not blocked by impurities
2. Lower ambient temperature
C5 High Supply
Temp.
1. Water inlet temperature is above 70°
1. Lower the water temp. (max 70°C)
2. Contact your local service technician.
C6 Low Sensor
Supply Voltage
1. Voltage supply for sensors too low
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C7 No Response
Error
1. No communication between display and control
board
1. Contact your local service technician.
C8 Low Tank
Level
1. Insufficient water supply
2. Water supply valve not open
1. Check correct water supply
2. Secure suffcient air supply to valve
3. Contact your local service technician.
C9 High Tank
Level
1. Water supply valve not closed
1. Secure sufficient air supply to the
valve.
2. Contact your local service technician.
C11 Warning
Cri. Inlet press.
1. Insufficient water supply
2. Booster will return to standby mode after 20 sec.
If this error occurs 3 times within 20 min. Error C2
occurs.
1. Secure suffcient water supply or re
-
duce consumption
2. Check inlet filter for impurities/rinse
filter
3. Contact your local service technician.
C13 Warning
Low inlet press.
1. Insufficient water supply.
The machine will keep on working as always, but the
maximum speed of the pump will be reduced until
sufficient inlet pressure is present.
1. Secure sufficient water supply or
reduce consuption
2. Check inelt filter for impurities/Rinse