2.1 Requirements/Specifications
2.2 Utility Requirements
2.2.1 Electrical Supply Requirements
• A constant 120 VAC/60 Hz. power source is required.
• The pump Cabinet is shipped with a 9’ power cord.
• For distance greater than 9’, the Pump Cabinet must be hard wired with conduit.
• The double pole single throw ON/OFF switch is also a circuit breaker rated at 3.0 amps.
• Total amperage draw during normal operation is approximately 2.5 amps.
2.2.2 Water Supply Requirements
• A 3/8” MNHT hot water supply line is required. The NSF hose is shipped in the Installation Kit.
• Water temperature should not fall below 95°F (35°C).
• Water flow rate is 0.8 GPM.
2.2.3 Electrical
The SCLS IV/AQUANOMIC EU IV does not require any additional electrical or water service relative to the main
dispenser. The SCLS IV/AQUANOMIC EU IV runs on 24 volt electrical service originating from the main
dispenser cabinet. The SCLS IV/AQUANOMIC EU IV uses water from the main dispenser and therefore does
not require additional water hook up.
SCLS IV/AQUANOMIC EU IV Dispensing Module Installation & Operation Manual
2-1