Ecolab AQUANOMIC EU IV Installation And Operation Manual Download Page 14

3-4 

SCLS IV/AQUANOMIC EU IV Dispensing Module Installation & Operation  Manual

 

Summary of Contents for AQUANOMIC EU IV

Page 1: ...GMODULE Installation and OperationManual Retainthismanual for installation operation and servicing information 370 Wabasha Street N St Paul MN 55102 www ecolab com 2016 Ecolab Inc All rights reserved...

Page 2: ...ater Supply Requirements 2 1 2 2 3 Electrical 2 1 2 3 Specifications 2 2 2 3 1 Dimensions 2 2 3 1 System Installation 3 1 3 2 Installation Procedure 3 1 3 1 1 Mounting the SCLS IV to the SCLS 3 1 3 3...

Page 3: ...ing instructions are for use by qualified personnel only The installation must be made in accordance with local plumbing and electrical codes 1 3 SystemFeatures The SCLS IV AQUANOMIC EU IV DISPENSING...

Page 4: ...ftene r Nozzle Sump Detergent Solenoid Valve Sump Bleach Solenoid Valve Pressure Gauge N O N C Softene r Control Valve Main Solenoid Valve Pump Inlet Hose Regulator Water Strainer Inlet Assembly Pump...

Page 5: ...1 2 SCLS IV AQUANOMIC EU IV Dispensing Module Installation Operation Manual...

Page 6: ...WaterSupplyRequirements A 3 8 MNHT hot water supply line is required The NSF hose is shipped in the Installation Kit Water temperature should not fall below 95 F 35 C Water flow rate is 0 8 GPM 2 2 3...

Page 7: ...e dispenser module assembly has the following dimensions Height 20 1 4 including standpipe 22 Width 10 1 4 Depth 11 Weight 15lbs withproduct up to 21 lbs Product clearance needs to be 8 above the cabi...

Page 8: ...Disconnect the communications cables c Turn off the water supply d Disconnectthe productdelivery tubing e Removetheoverflowhose f Remove the solid products g Remove Cabinet from the wall 3 1 1 Mounti...

Page 9: ...SCLS IV AQUANOMIC EU IV Dispensing Module Installation Operation Manual 3 1...

Page 10: ...to the male quick disconnect of the reed switch assembly white wires 4 Connect the white orange wire to the open 1 4 tab of the 4th product valve 5 Connect the red and the white red wires to the open...

Page 11: ...to the T connector 3 Feed the 1 4 white tubing from the SCLS IV AQUANOMIC EU IV cabinet through the top hole on the left side of the SCLS IV AQUANOMIC EU IVcabinet 4 Connect this 1 4 white tubing into...

Page 12: ...SCLS IV AQUANOMIC EU IV Dispensing Module Installation Operation Manual 3 3...

Page 13: ...MIC EU cabinet 7 Attach the 4th product drain hose to the SCLS AQUANOMIC EU drain hose using the connector tube and two hose clamps as shown in Figure 3 4 below Be sure drain tube is not kinked Shorte...

Page 14: ...3 4 SCLS IV AQUANOMIC EU IV Dispensing Module Installation Operation Manual...

Page 15: ...the Fourth Product selection then press Enter 4 The Fourth Product Installed screen should be displayed Press the Choice key until the Yes response is indicated and then press the Enter key to save t...

Page 16: ...uct Dispenser 6 In the Outputs menu press On Off key to turn the main flush display to on Press the Down arrow once and then press On Off key to turn washer 1 display to on Press the Down Arrow six ti...

Page 17: ...Switch is normally open 2 Bad product valve a Solenoid diaphragm failed b Coil failed c With cabinet dispensing product check for 24 VAC onthecoil leads Removethe leads from the coil totest d If 24 V...

Page 18: ...EMBLY 2 8305 1136 PROXIMITY SWITCH 3 9258 2592 FLUSH SPRAY TUBE 4 9259 2640 PRODUCT SPRAY TUBE 5 8531 2718 FLUSH NOZZLE 180 SPRAY SST 6 8531 2502 PRODUCT NOZZLE 67 KYNAR 7 8720 6165 O RING EPDM 8 9258...

Page 19: ...370 Wabasha Street N St Paul MN 55102 www ecolab com 2016 Ecolab Inc All rights reserved 29516 0406 0216 Part No 9259 2002 7 2 SCLS IV AQUANOMIC EU IV Dispensing Module Installation Operation Manual...