11
Eng
lis
h (
EN
)
3.3.
Specifications
Technical data
Air
Unit
Min/max air pressure.
MPa (bar)
0,7-1,0 (7-10)
Compressed air consumption.
NL/min
500
Air quick connector
-
General
Product flowrate
ml/min
380
Sound level ISO 11202
dB
Below 70
Weight
Kg
22.4
4. Overview and Use
Drainspexx is an equipment allowing to easily apply a fog of a disinfecting biocide to the surface of pre-cleaned
drain pipes / channels. The biocide can be left on the surfaces without rinsing.
In effect it leads to a reduction of germs at these surfaces. Regularly applied, it is giving additional safety
against microbiological contaminations in the production area, provided the standard treatment for drain lines is
applied also.
A layout of the equipment can be found on page 27.
5. System Safety
•
The Drainspexx unit must only be used for professional use by a trained operator.
The only biocides allowed are listed below:
Biocides
Kenolox 10
Aseptanios AF 310
Availability may depend on government approvals in the individual country. Do NOT mix 2 different biocides.
If any other biocides are used serious injuries cannot be excluded. The use is restricted to closed drain pipe
systems. Apply to a single pipe system, drain by drain, one drain at a time. The manual must be followed strictly.
• The air pressure for the unit is set to 6 bar. It must not be changed.
Safety
Wear appropriate PPE
•
Working boots class S2.
•
Safety glasses.
•
Gloves and suitable clothing.
Wear glasses when using
the unit.
Wear gloves and suitable
clothing when using the
unit.
Summary of Contents for 110007932
Page 6: ...6 English EN...
Page 20: ......
Page 34: ......
Page 48: ...48 Espa ol ES...
Page 62: ...62 Nederlands NL...
Page 76: ...76 Polski PL...
Page 90: ......
Page 92: ...English EN 6 8 7 5 12 13 13 12 10 11 12 9 2 3 4 1 14 15 16 110008048 92 English EN...
Page 96: ...Layout Drainspexx 96...