2.20.
The appliance is intended to be permanently connected to water main with a normally closed valve; do not
use a hose-set.
Drawing
2
3.
FUEL.
Your stove
is designed to operate
with wood pellets;
however, it can also work with other biomass fuels (ask
your dealer about this). If using a different type of biomass is possible, select it from the fuel selection menu (check
user manual). In most cases, the combustion basket is not the same as for wooden pellets.
ECOFOREST
do not have any control on the quality of the fuel you use. For this reason,
ECOFOREST
cannot
guarantee the full output of your stove nor the eventual premature aging or eventual damage of the gas outlet. The
fuel’s minimum requirements are specified below:
Pellets
Olive pits
Almond shells
Diameter (mm)
6
— —
— —
Length (mm)
5-25
— —
— —
Granulometry (mm)
— —
3 - 4
6 - 8
Calorific value (Kcal/kg)
≥ 4300
≥ 3800
≥ 3700
Ash (% mass)
< 1.5
< 1.5
< 1.5
Humidity (%mass)
< 12
< 12
< 12
Oils
— —
No oil content
— —
Grill and/or specific strangler.
ORIGINAL
SPECIFIC
SPECIFIC
4.
INSTALLATION.
The below security distances and assembly diagrams are given for information only as an adaptation shall be
made depending on the norms in force regarding gas outlet, power, security minimum distances specific to
geographic areas.
Air inlets and water connections will be missed in all drawings as section 4.16 indicates the minimum
security distances to be respected for their installation.
ELECTRICAL CONNECTION.
The power socket to which the stove is plugged should meet the following requirements:
4.1.
Ground connection must comply with the specific applicable regulations.
4.2.
Differential switch with the correct amperage. It must comply with the specific applicable regulations (check
technical specifications of the stove).
4.3.
Single-phase AC of ~230/240V – 50Hz and pure sine wave.
4.4.
The plug must only be connected to a socket with the technical characteristics of the plug in question.
4.5.
Easily accessible power socket. If the power socket can’t be accessed due to the characteristics of the
electrical installation, an all-pole disconnection switch must be installed.
Heat flow. (See technical features).
Heating return. (See technical features).
Safety valve discharge. (See technical
features).
Charge-discharge. (See technical features).
Drain siphon.
Normally closed valve
Water main.
Summary of Contents for CS 2012/08
Page 1: ......
Page 6: ...5 1 ESPECIFICACIONES T CNICAS CANTINA SUPER CS 2012 08 HIDRO 24 HC 2015 HIDRO 16 HB 2015...
Page 27: ...26 1 TECHNICAL FEATURES CS 2012 08 HC 2015 HB 2015...
Page 48: ...47 1 SP CIFICATIONS TECHNIQUES CS 2012 08 HC 2015 HB 2015...
Page 70: ...69 1 SPECIFICHE TECNICHE CS 2012 08 HC 2015 HB 2015...
Page 92: ...91 1 ESPECIFICA ES T CNICAS CS 2012 08 HC 2015 HB 2015...
Page 113: ...112...