![Ecoflam Multicalor 1000.1 Manual Download Page 26](http://html1.mh-extra.com/html/ecoflam/multicalor-1000-1/multicalor-1000-1_manual_2354200026.webp)
1) Remove the cap A of the pressure
regulating valve TV.
2) Loosen the fixing nut B and use an
allen wrench on the screw C to adjust
the delivery oil pressure. To increase the
pressure turn clockwise, to decrease the
pressure turn anticlockwise.
3) Tighten the nut B and pay attention
not to turn also the adjusting screw.
4) Screw on the cap A, back to its pre-
vious position.
PRESSURE REGULATING VALVE ADJUSTMENT
A
B
C
B
A
1
2
3
4
EN
420010401800
Multicalor 700.1 - 1200.1 PR/PR
26