![Ecoflam MAX GAS 350 P Manual Download Page 16](http://html1.mh-extra.com/html/ecoflam/max-gas-350-p/max-gas-350-p_manual_2354180016.webp)
16
www.ecoflam-burners.com
EN
420010492303
Service
- Maintenance
10
11
12
Fan assembly
Observe the positioning diagram above
when replacing the motor and blower
wheel. The inside flange
A
of the blower
wheel must be fitted at the same level as
the equipment plate
B
. Insert a straight
edge between the wing of the blower wheel
and set
A
and
B
to the same height, tighten
the set screw on the blower wheel
(maintenance position 1).
Maintenance on the burner
• Check gas supply components (tubes,
lines) and their connections for leaks
or signs of wear, replace if necessary.
• Check electrical connections and
connection cables for damage,
replace if necessary.
• Check gas filter, clean or replace as
necessary.
• Clean fan wheel and housing and
check for damage.
• Check and clean the mixing unit.
• Check ignition electrodes block,
readjust or replace as necessary.
• Start burner, check flue gas data,
correct burner settings if necessary.
• Check the setting for air pressure
switch and gas pressostat.
• Check the gas train settings.
13
14
15
16
WARNING
• Carry out an operating check.