14
420010251101
M aior P 45/60/80/120 PR SW
EN
AIR ADJUSTMENT
+
- -
Part. 1
Part. 2
Part. 3
-
+
-
COMMUTATORE
0
AUTO
0 = bloccaggio degli apparati per il
funzionamento in una posizione intermadia
=
funzionamento alla massima potenza
=
funzionamento alla minima potenza
AUTO = funzionamento automatico
operating elements locked in an intermediate position
operation on maximum capacity
operation on minimum capacity
automatic operation
SELECTOR
MINIMUM CAPACITY ADJUSTMENT OF THE BURNER
Position the selector, situated on the control panel, on position 2 and proceed as follows:
Adjustment the minimum light oil flow rate (see figure, Nozzle diagram):
- using a suitable allen key, change the position of the cam guide blade; screwing the cam in, the
light oil flow increases, while unscrewing it, it decrease.
Adjustment the minimum air flow rate (see figure, detail 1):
- loosen the Allen screw on the air damper clamp;
- turn the air damper until you reach the correct air flow, as established by analyzing
the combustion process.
- tighten the Allen screw in place once again.
MAXIMUM CAPACITY ADJUSTMENT OF THE BURNER
Position the selector, situated on the control panel, on position 1 and proceed as follows:
Adjustment the maximum light oil flow rate (see figure, Nozzle diagram):
- using a suitable allen key, change the position of the cam guide blade ; screwing the cam in, the
light oil flow increases, while unscrewing it, it decrease.
Adjustment the maximum air flow rate (see figure, detail 2):
- loosen the nut holding the air damper transmission rod;
ADJUSTMENT THE INTERMEDIATE BURNER CAPACITIES
Using the selector, start the servomotor (closing or opening) and position on 0 to stop the stroke; the adjust-
ment is made as outlined below. Repeat the operation for the other cam points.
Adjustment the intermediate light oil flow rates (see figure, detail 3):
- using a suitable Allen wrench, change the position of the cam guide blade; if you screw it