8
www.ecoflamburners.com
EN
420010930200
WORKING DIAGRAMS
TEST BOILER FLAME DIMENSIONS
The burner/boiler matching does not pose
any problems if the boiler is CE type-
approved.
If the burner must be combined with a
boiler that has not been CE type-approved
and/or its combustion chamber dimensions
are clearly smaller than those indicated in
diagram, consult the manufacturer.
The firing rates were set in relation to
special test boilers, according to EN676 -
EN267 regulations.
The sizes are indicative and dipend on
the configuration, to the combustion
chamber pressure and to the draught.
The values have been taken out from
tests executed with flame tubes.
The dimensions of the flame are made
in test boiler in laboratory without
resistence therefore exists max and
min lenght that take into account the
difference in lenght that comes from the
boiler backpressure.
Example:
Burner thermal output = 8000 kW;
L flame (m) = 5 m (medium value)
D flame (m) = 1 m (medium value)
WARNING:
Some flame modifications
can be done in our FLEXSHOP in the
factory in order to shape the flame and
adapt it to some special boiler
or application.
L (m)
2000
3000
4000
5000
6000
7000
8000
9000
10000
4
5
1000
2000
3000
1000
6
11000
0
2
3
7
8
12000
kW
13000
9
10
11
Nm3/h
100
200
300
400
500
kcal/h
x 1000
4000
5000
6000
7000
8000
9000
10000
11000
12000
13000
14000
15000
14000
15000
16000
17000
Ø (m)
2000
3000
4000
5000
6000
7000
8000
9000
10000
0,6
0,8
1000
2000
3000
1000
1
11000
0
0,2
0,4
1,2
1,4
12000
kW
13000
1,6
1,8
2
kcal/h
x 1000
4000
5000
6000
7000
8000
9000
10000
11000
12000
13000
14000
15000
14000
15000
16000
17000
FLAME LEN
G
H
T
G
AS BURNERS
FLAME DIAME
T
ER
G
AS BURNERS
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1700
Nm3/h
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1700
0
5
10
15
20
25
30
35
4
0
0
2000
4
000
6000
8
000
10000
12000
1
4
000
0
2000
4
000
kW
kcal/h*
1000
6000
8
000
10000
12000
mbar
BLU 7000.1
BLU 12000.1
BLU 10000.1
BLU 8000.1
Working diagrams
The working diagram shows
burner output as a function of
combustion chamber pressure.
It corresponds to the maximum
values specified by EN 676
measured at the test fire tube.
Boiler efficiency should be
taken into consideration when
selecting the burner.
Calculation of
burner output
QF = Burner output (kW)
QN = Rated boiler output(kW)
η = Boiler efficiency (%)
QF =
QN x 100
η
Summary of Contents for 3145132
Page 26: ...26 www ecoflam burners com EN 420010930200 APPENDIX Electrical diagrams...
Page 27: ...27 www ecoflam burners com EN 420010930200 APPENDIX Electrical diagrams...
Page 28: ...28 www ecoflam burners com EN 420010930200 APPENDIX Electrical diagrams...
Page 29: ...29 www ecoflam burners com EN 420010930200 APPENDIX Electrical diagrams...