Typical Installation Illustrations

FIG. 7

Drain

Fitting

Valve

Drain

Hose

Valve

Drain

Hose

1-1/2”

Air Gap

1-1/2”

Air Gap

1-1/2”

Air Gap

1-1/2” Air Gap

LAUNDRY

TUB

SUMP

STAND

PIPE

FLOOR

DRAIN

To standpipe, sump, laundry

tub or other suitable drain.

1/2” I.D.

(minimum)

copper tube

Push 

in

for

Bypass

Clip

Drain Fitting

CONNECTING A RIGID VALVE DRAIN TUBE

To adapt a copper tube to the filter, buy a compression fitting (garden hose thread to

1/2” I.D. minimum tube and necessary tubing from your local hardware store.

Adaptor, garden hose

thread to compression

Pull 

out

for

filtered water

Service”

FIG. 6

FIG. 5

INSTALLATION USING 3-VALVE BYPASS

MAIN WATER 

PIPE

MAIN WATER 

PIPE

INSTALLATION USING INCLUDED BYPASS VALVE

CROSS-OVER

Use if water supply flows from the left.

Include single or 3-valve bypass.

Filtered

Water 

OUT

Unfiltered

Water 

IN

Unfiltered Water

to Outside Faucets

120V,

60 Hz

Outlet

FILTERED

WATER

TO FILTER

INLET

UNFILTERED

WATER

FROM FILTER

OUTLET

BYPASS

Valve

OUTLET

Valve

INLET

Valve

1” NPT

Adaptor (2)

not included

Clip (2)*

O-Ring Seal (2)*

1” NPT Installation

Adaptor (2)*

Valve

INLET

For filtered water SERVICE:
-Open the inlet and outlet

valves

For unfiltered BYPASS:
-Close the inlet and outlet

valves

-Open the bypass valve

* Included with filter - Pipe and

fittings supplied by installer.

1” NPT

Adaptor (2)

not included

1” NPT Installation

Adaptor (2)*

Bypass Valve*

Clip (4)*

O-Ring Seal (2)*

Power

Supply

Summary of Contents for HPF

Page 1: ...NSAPFXLA tested and certified without media by the Water Quality Association under NSF ANSI Standard 61 for material safety requirements only and NSF ANSI Standard 372 for low lead content Not certif...

Page 2: ...hold outlet that is in a dry location only grounded and properly protected by an overcurrent device such as circuit breaker or fuse This system is not intended to be used for treating water that is mi...

Page 3: ...1 1 1 1 Filtering Micron Rating 20 Supply Water pH Limits 6 0 6 8 Capacity 34 000 gal 15 500 gal at 10 psi maximum pressure drop at 35 psi inlet pressure Valve inlet outlet and installation adaptors...

Page 4: ...ts of tastes and odors and or higher water usages may shorten this time Activated carbon can t be regenerat ed and must be replaced when exhausted see page 16 WATER NEUTRALIZING FILTER All water when...

Page 5: ...lled indoors Keep the filter out of direct sunlight The sun s heat may soften and distort plastic parts TOOLS PIPE FITTINGS OTHER MATERIALS YOU WILL NEED Plastic inlet and outlet fittings included wit...

Page 6: ...sh the tank opening with water to clean media particles from the top of the tank Uncover the bottom distributor stand tube 11 Finish filling the tank with water up to the top of the tank IMPORTANT Be...

Page 7: ...G 5 INSTALLATION USING 3 VALVE BYPASS MAIN WATER PIPE MAIN WATER PIPE INSTALLATION USING INCLUDED BYPASS VALVE CROSS OVER Use if water supply flows from the left Include single or 3 valve bypass Filte...

Page 8: ...ring Clip Cross section of valve inlet or outlet Bypass valve or plastic adaptor Snap clips into place between larger diameter rings FIG 11 Turn the bypass valve downward if connecting to floor level...

Page 9: ...ting the hose may cause a back pressure that could reduce backwash flow and proper mineral bed cleaning 6 FLUSH PIPES CIRCULATE DISINFEC TANT EXPEL AIR FROM FILTER AND TEST YOUR INSTALLATION FOR LEAKS...

Page 10: ...to a 120V 60 Hz electrical outlet Be sure the outlet is always live so it can not be switched off by mistake Installation Instructions 8 PROGRAM THE TIMER See pages 11 12 for instructions to program t...

Page 11: ...advance the display Hold the buttons down for fast advance 2 When the correct time is displayed press the SELECT button and the display will change to show the next setup screen 2 The default setting...

Page 12: ...this time as the water heater will refill with unfiltered water FIG 19 VACATION CONTROL 1 Before going on vacation or other long absence press but do not hold the TOUCH HOLD button so that VAC begins...

Page 13: ...Use the r UP or s DOWN buttons to adjust solu tion draw rinse time from 0 to 255 minutes 3 When the desired draw time is displayed press the SELECT button and the display will change to show the 12 24...

Page 14: ...he table below explains the choices available for when the auxiliary output will be on dur ing various portions of the recharge cycle FIG 26 SELEC TION NAME AUXILIARY OUTPUT FUNCTION OFF Off Remains o...

Page 15: ...is difficult to determine exactly when to add more mineral When you have had the filter for a period of time experience will tell you when to add more mineral You can use the instructions following s...

Page 16: ...the filter from the instal lation adaptors or from the bypass valve Figure 8 page 8 5 Remove the two clamp retainers and two clamp sections that hold the valve to the tank Lift the valve assembly up a...

Page 17: ...to check flow control See page 22 to check for correct assembly and orientation Backwash flow should be 5 gpm or higher Low water pressure at house faucets Well pump pressure switch set too low Adjust...

Page 18: ...ronic Control Board PWA TO REMOVE AN ERROR CODE 1 Unplug the power supply 2 Correct the problem 3 Plug the power supply back in 4 Wait for at least 8 minutes while the timer operates the valve through...

Page 19: ...D button to manually advance the valve into each position and check correct switch operation 4 While in this diagnostic screen the following infor mation is available and may be beneficial for vari ou...

Page 20: ...Position Switch S SERVICE Valve Cam FIG 38 BR FILL F BRINE DRAW Position Switch Valve Cam FIG 39 Position Switch Valve Cam FIG 40 BW BACKWASH FAST RINSE Position Switch Valve Cam FIG 41 Position Switc...

Page 21: ...ng 2 3 4 x 3 11 7088855 Top Distributor 12 7105047 Repl Bottom Distributor 13 7092202 Mineral Tank 10 x 47 7113074 Mineral Tank 12 x 54 14 7339141 Catalytic Carbon 1 cu ft Chloramine Chlorine Taste Od...

Page 22: ...2 Valve Exploded View Wear Strip Seal Cross section View 52 50 53 54 55 51 56 57 58 59 60 61 66 67 78 62 63 64 68 69 65 77 70 83 72 70 71 72 73 74 75 76 79 80 81 82 84 Flow Plug Assembly Assembled Vie...

Page 23: ...g Wave Washer 67 7185500 Rotor Disc Key No Part No Description 7342712 Drain Plug Kit 1 includes Key Nos 64 68 69 68 Plug Drain Seal 69 Spring 70 7089306 Clip 1 single 2 req 7336428 Clip 1 pack of 20...

Page 24: ...orce of nature such as but not limited to freezing flood hurricane tornado or earthquake is not covered by this warranty In all such cases regular parts and serv ice charges will apply We assume no wa...