9
Installation
TTD101 can be quickly and easily mounted on all
common valves (see adapter table). It can be installed
without mess and water leaks because the heating
circuit is not interrupted.
1. Turn the manual thermostat head up
completely, loosen the fastening and
pull the thermostat off of the valve.
2. Use an appropriate adapter, if required,
and push it onto the valve.
3. Screw the connector on the valve
or the adapter.
4. Now, you put TTD101on the
connector until it noticeably clicks into place.
ATTENTION: It must be possible to insert TTD101
without applying force, ensure that the appliance is in
the „
“ or „
ON
“ position.
valve – adapter – coupling ring
valve – coupling ring
Additional information about the different adapters are
provided on page 20 or at: www.ecodhome.co.uk