39
Main menu
Long Press
[Initial setting wizard]
screen and main settings menu screen in order. Enter the desired number using the function keys and press CONFIRM.
Note:
<[HEATER CAPACITY RESTRICTION]>
This setting restricts the booster heater capacity. It is NOT possible to change the setting after starting up.
If you do not have any special requirements (such as building regulations) in your country, skip this setting (select “No”).
• [Hot water (DHW/Legionella)]
• [Heating]/[Cooling]
• [Operation (ON/Prohibited/Timer)]
• [Pump speed]
• [Mixing valve control]
• [HEATER CAPACITY RESTRICTION]
Initial settings wizard
DHW SETTINGS
Operation mode
Skip
Main Settings Menu
The main settings menu can be accessed by pressing the MENU button. To re-
duce the risk of untrained end users altering the settings accidentally there are
two access levels to the main settings; and the service section menu is password
protected.
User Level – Short press
If the MENU button is pressed once for a short time the main settings will be
displayed but without the edit function. This will enable the user to view current
settings but
NOT
change the parameters.
Installer Level – Long press
If the MENU button is pressed down for 3 seconds the main settings will be dis-
played with all functionality available.
The colour of
The following items can be viewed and/or edited (dependent on access level).
• [Domestic Hot water (DHW)]
• [Heating/Cooling]
• [Schedule timer]
• [Holiday mode]
• [Initial settings]
• [Service (Password protected)]