![Ecodan EHPT15X-UKHDW1S Installation Manual Download Page 11](http://html.mh-extra.com/html/ecodan/ehpt15x-ukhdw1s/ehpt15x-ukhdw1s_installation-manual_2353984011.webp)
11
KEY
A
OVERALL HEIGHT
B
HEAT PUMP FLOW CONNECTION (22mm O/D COPPER)
C
TUNDISH OUTLET CONNECTION (22mm COMPRESSION)
D
HEAT PUMP RETURN CONNECTION (22mm O/D COPPER)
E
HEATING ZONE 1 CIRCUIT FLOW CONNECTION (22mm O/D COPPER)
F
HEATING ZONE 1 CIRCUIT RETURN CONNECTION (22mm O/D COPPER)
G
COLD WATER INLET CONNECTION (22mm COMPRESSION)
H
HOT WATER OUTLET CONNECTION (22mm COMPRESSION / 3/4” BSP M)
J
THW5A SENSOR POCKET
K
WI-FI ADAPTOR (INCLUDED, INSTALLER TO LOCATE AND MOUNT)
CAPACITY
150
170
A
1516
1690
B
1127
1127
C
909
1083
D
1127
1127
E
194
194
F
350
350
J
943
1117
K
Installer to locate and mount
Fig. 2c - Dimensions and EU Product Fiche - 22mm Slimline Models
MODEL
Energy efficiency
class
C
C
Standing loss in W
58.3
66.3
Storage volume V in
Litres
150
170
Technical parameters in accordance with European Commission
regulations 814/2013 and 812/2013
676
654
491
B & D
A
J
C
G
H
B D
K
E
F
EHPT15X-UKHLDW1S
EHPT17X-UKHLDW1S
Summary of Contents for EHPT15X-UKHDW1S
Page 50: ...50 Notes ...
Page 51: ...51 Notes ...