background image

Important Safety Information

General Safety Information

This manual contains important safety, installation, and operating 

instructions for the inverter.The following symbols are used throughout 

the manual.

Warning:

i

ndicate a potential dangerous condition.Use extreme 

caution when performing this task.

Caution:

indicate a critical procedure for safe and proper operation of 

the inverter.

Note:indicate a procedure or function that is important to the safe and 

proper operation of the inverter.

Installation and wiring must comply with the Local and National Electric 

Codes(NEC) and must be done by a certified technician.

Read all of the instructions and caution in the manual before beginning 

the installation.

There are no serviceable parts for this inverter.do not disassemble or 

attempt to repair the inverter.

Make sure all connections going into and from the inverter are 

tight.There may be sparks when making connection,therefore,make 

sure there are not flammable materials or gases near installation.

-1-

Summary of Contents for CSP1500

Page 1: ......

Page 2: ...rmation General Safety Information Inverter safety Bayttery Safety General Information Key feature Installation Operation Maintenance Troubleshooting 1 1 2 2 5 3 5 8 8 10 Location Recommendation Wiring Step Solar Panel Wiring 5 6 7 ...

Page 3: ...procedure or function that is important to the safe and proper operation of the inverter Installation and wiring must comply with the Local and National Electric Codes NEC and must be done by a certified technician Read all of the instructions and caution in the manual before beginning the installation There are no serviceable parts for this inverter do not disassemble or attempt to repair the inv...

Page 4: ...ead acid flooed gel or LiFePO4 batteries which musst be deep cycle Be careful when working with large lead acid batteries Wear eye protec tion and have fresh water avaiable in case there is contact with the battery acid Over charging and excessive gas precipitation may damage the battery plates and activate material shedding on them Too high of an equalizing charge or too long of one may cause dam...

Page 5: ...D display and intelligent LEDs providing important system information 4 Manual ON OFF switch controlling AC output 5 Adjustable fan efficient heat dissipation extending the life of the system 6 Supports lead acid battery and lithium battery types 7 Solar protection PV Short circuit protection PV reverse protection PV overvoltage protection 8 Battery protection Undervoltage protection overvoltage p...

Page 6: ...Dimensions Solar input terminal Battery terminal AC Outlets 4 ...

Page 7: ...it should be away from any flam mable material liquids or any other combustible material 3 Close proximity to battery bank Prevent excessive voltage drop by keeping the unit close to the battery bank and having a properly sized wire going from the battery bank to the inverter 4 Do not install the inverter in the same compartment as the battery bankbecause it could serve as a potential fire hazard ...

Page 8: ... To minimize sparking it is recommended that the user have the appropriate size wire feeding into the solar inverters and or install an external fuse leading into the inverter The solar inverter takes a 12V 600W or 24V 1500W battery input to operate This will require combining 12V or 6V batteries in series to achieve the minimum voltage DC requirement It is recommended to use battery cables with r...

Page 9: ...ecommended to use a combiner box for safety and organizational precautions This will require combin ing solar panels in series or series parallel to achieve the minimum voltage DC requirement Caution Connect the positive and negative PV wire to the respective positive and negative PV terminal block on the solar inverter Solar Panel Wiring 24V Solar system 12V Solar system ...

Page 10: ...rder to maintain optimal long term performance it is recommended to perform inspections of the following items twice a year 1 Make sure that the air flow around the solar inverter is not blocked and remove any dirt or debris from the radiator 2 Check all terminals to see if there is corrosion insulation damage high temperature or combustion discoloration signs tighten the termi nal screws 1 Solar ...

Page 11: ...ltage AC Output Frequency Output Wave AC Output Sockets Size Weight Model 12V 600W 1200W 500W 30A 12V 1 275 185 74 2 36Kg 24V 1500W 3000W 1200W 50A 24V 2 319 235 100mm 4 5Kg 120VAC 12V 230VAC 23V 50Hz 60Hz Pure Sine Wave 600W 12V 110V 230V CSP600 Pure Sine Wave 10Vdc 15Vdc 20Vdc 30Vdc PVM Protect Function PV Reverse Input Protection PV Short Circuit Protection Over Heating Protection Over Charge P...

Page 12: ...erload DC DC voltage increase system failed long working time Overload Cooling system too many solar panels in series wrong solar panel reduce amount of solar panels in series choose suitable panels Low battery power Overdischarge recovery time charge your battery Restart Wrong battery type Overcharge recovery time choose right battery type Restart DC DC voltage increase system failed Solution rep...

Reviews: