9
below table.
If lamp cable is damaged, replacement should be operate by factory or qualified
staff. Any question, please contact professionals or talk to a qualified electrician.
Live wire(L)
Null(N)
Ground wire
RED
BLUE
Green
6. LAMP
6.1 LAMP DESCRIPTION
LAMP MODEL
POWER OF LAMP
LIFE/HOUR
COLOR TEMPERATURE
Philips UHP
189 W
2200 HOUR
8000K
YODN 5R
200 W/230W
2200 HOUR
8000K
WARNING! There is a safety hazard or damage if install similar bulb
To reduce the risk of damage to light ,do change the lamp before using
time over 125% of lamp life .
6.2 LAMP REPLACE
Attention! When replace the lamp is forbidden to touch lamp with bare hand, to
avoid the greasy dirt stains filament. filament must be kept clean
1. Disconnect the power. Before replace lamp, fixture need 20 minutes for lamp
cooling. Fasten the head with Y axis protect lock in 60 ° position.
2. Use cross screwdriver to open the light body cover, remove the fan bracket,
pull out the bulb cable
3. Open stainless steel tablet holder with one hand and the use other hand to pull
out the bulb at oblique 15 °
4. Install the lamp
7. CONTROL PANEL
7.1 CONTROL PANEL INTORUCTION
POWER SIGNAL
LIGHT
DMX SIGNAL
LIGHT
DISPLAY SCREEN
BUTTON