Troubleshooting Guide

PROBLEM

CAUSE

CORRECTION

No soft water

1. No salt in the storage tank.

Refill with salt and then use RECHARGE NOW feature.

No soft water & dis-

play is blank

1. Power supply unplugged at wall outlet, or

power cable disconnected from back of elec -

tronic board or power supply malfunction.

Check for loss of power and correct.  Reset electronic

controls and then use RECHARGE NOW feature.

2. Fuse blown, circuit breaker popped, or cir-

cuit switched off (See “Power Outage

Memory” on Page 16).

Replace fuse, reset circuit breaker, or switch circuit on,

and then use RECHARGE NOW feature.

3. Electronic control board malfunction.

Replace electronic control board (See Page 23).

No soft water & salt

level not dropping

1. Salt storage tank “bridged”.

Refer to “Breaking a Salt Bridge” section to break.

2. Bypass valve(s) in “bypass” position.

Move bypass valve(s) to “service” position.

No soft water & salt

storage tank full of

water,

water running to

drain while unit is in

the soft water cycle

1. Dirty, plugged or damaged nozzle & venturi

assembly

Take apart, clean and inspect nozzle & venturi (See

“Cleaning the Nozzle & Venturi” section.

2. Inner valve fault causing leak.

Replace seals and rotor.

3. Valve drain hose is plugged.

Hose must not have any kinks, sharp bends or any water

flow blockage (See “Valve Drain Requirements” section.

4. Valve drain line and Salt Storage Tank

overflow drain connected together by a tee.

Disconnect tee and run separate drain lines.

5. Low or high system water pressure (low

pressure may disrupt brine draw during

recharge, high pressure may cause inner

valve parts failure).

If pressure is low, increase well pump output to a mini-

mum 20 psi.  If daytime pressure is over 100 psi, add a

pressure reducing valve in the supply pipe to the water

treatment system.  Contact a licensed plumber.

6. Brine float dirty or broken.

Clean or replace Brine Valve Float Assembly.

7. Leak between valve and resin tank.

Replace o-rings between resin tank and valve.

Water hard some-

times

1. Incorrect time set.

Check and change time setting.

2. Incorrect water hardness set.

Refer to “Set Water Hardness” section to set correctly.

3. Incorrect model code programmed.

Refer to “Program the Water Treatment System” section

to set correctly.

4. Hot water being used when system is

regenerating.

Avoid using hot water while the system is regenerating,

as the water heater will fill with hard water.

5. Possible increase in water hardness.

Test untreated water for hardness and iron, and program

the water treatment system accordingly (See “Set Water

Hardness”) section to set.

6. Leaking faucet or toilet valve.  Excessive

water usage.

A small leak can waste hundreds of gallons of water in a

few days.  Fix all leaks and always fully close faucets.

Iron in water

1. Clear water iron in water supply.

Test untreated water for hardness and iron, and program

the water treatment system accordingly (See “Set Water

Hardness”) section to set.

2. Iron in soft water.

Clean resin bed with Resin Bed Cleaner.  Follow instruc-

tions on package.

3. Bacterial or organic bound iron.

Cannot be treated by this system.

Resin in house hold

plumbing

1. Crack in distributor or riser tube.

Replace resin tank assembly.

Salt storage tank

leaking

1. Crack in brine tank.

Replace salt storage tank assembly.

Motor stalled or

clicking

1. Motor malfunction or internal valve fault

causing high torque on motor.

a. Replace rotor/seal.

b. Replace motor & switch.

Error code E1, E3 or

E4 appears

1. Fault in wiring harness or connections to

position switch.

Replace wiring harness or connections to position switch.

2. Fault in switch.

Replace switch.

3. Fault in valve causing high torque.

Replace rotor/seal.

4. Motor inoperative.

Replace motor.

Error code E5

1. Electronic control malfunction.

Replace electronic control board.

Summary of Contents for EPHY

Page 1: ...r visit www ecopure com When you call please be prepared to provide the model and serial number of your product found on the rating decal located on the rim below the salt lid hinges System tested and...

Page 2: ...perated at a sustained maximum service flow rate greater than its listed rating This system has been proven to deliver soft water for at least ten continuous minutes at the rated service flow rate The...

Page 3: ...vice Flow Rate 6 5 gpm 24 6 lpm Amount of High Capacity Ion Exchange Resin 0 94 cu ft 26 6 liters Pressure Drop at Rated Service Flow 12 8 psig Water Supply Max Hardness 95 gpg Water Supply Max Clear...

Page 4: ...nly grounded and properly protected by an overcurrent device such as a circuit breaker or fuse Do not use this system to treat water that is microbiologically unsafe or of unknown quality without adeq...

Page 5: ...icles After the water stands for a period of time the particles settle to the bottom of the container Generally these irons are removed from water by filtra tion Chlorination is also recommended for b...

Page 6: ...tem close to the water supply inlet and upstream of all other plumbing connections except outside water pipes Outside faucets should remain on hard water to avoid wasting treated water and salt A near...

Page 7: ...ystem not included can be purchased and assembled as shown in Figure 8 Bypass valves allow you to turn off water to the system for mainte nance if needed but still have water in house pipes Pipe fitti...

Page 8: ...d level surface IMPORTANT Do not place shims directly under the salt storage tank to level the system The weight of the tank when full of water and salt may cause the tank to fracture at the shim 2 Vi...

Page 9: ...tment system valve inlet side NOTE Inlet and outlet are marked on the water treat ment system valve Trace the water flow direc tion to be sure hard water is to inlet IMPORTANT Be sure to fit align and...

Page 10: ...d be sure all wiring is away from the valve gear and motor area which rotates during regenerations 1 Plug the water softener s power supply into an elec trical outlet that is not controlled by a switc...

Page 11: ...sanitiz ing bleach into and through the water softener Any air remaining in the unit is purged to the drain 4 After the recharge has completed fully open a cold water faucet downstream from the softe...

Page 12: ...nected to electrical power the light on the control panel will operate as follows Light flashing with the time of day shown in the display The salt monitor system indicates a low salt level and needs...

Page 13: ...on once again to display a flashing 2 00AM and the words SET RECHARGE TIME This is a good time for the recharge to start in most households because water is not in use FIG 20 SET SALT LEVEL The water...

Page 14: ...the screen When completed full water treatment capacity is restored RECHARGE NOW initiated FIG 22 RECHARGE TONIGHT initiated FIG 23 FIG 26 FIG 25 FIG 24 CLEAN FEATURE This feature is beneficial on wa...

Page 15: ...ault setting To change this setting 1 Press and hold the SELECT button until the screen in Figure 24 is displayed 2 Press the SELECT button three times so that 12 hr or 24 hr flashes in the display Se...

Page 16: ...age level lower and to refill more often to avoid salt bridging Recommended Salt Nugget pellet or coarse solar salts with less than 1 impurities Salt Not Recommended Rock salt high in impurities block...

Page 17: ...e water level in the tank This will also assure that the system is completely recharged and ready to provide softened water again Check the water level in the tank by look ing down the brinewell If th...

Page 18: ...Contact a licensed plumber 6 Brine float dirty or broken Clean or replace Brine Valve Float Assembly 7 Leak between valve and resin tank Replace o rings between resin tank and valve Water hard some t...

Page 19: ...water is in contact with the salt and not separated by a salt bridge See Breaking A Salt Bridge section 5 While in this diagnostic screen the following infor mation is available and may be beneficial...

Page 20: ...ing or brine valve riser pipe 2 After observing fill press the RECHARGE button to move the system s valve into the brine position A slow flow of water to the drain will begin Verify brine draw from t...

Page 21: ...21 Notes...

Page 22: ...22 8 7 6 5 Water Treatment System Exploded View 27 26 28 15 16 12 18 19 20 11 22 23 24 25 8 6 3 9 10 7 Valve Assembly See Pages 24 25 for parts 5 2 1 21 4 14 13 17...

Page 23: ...16 7331834 Repl Electronic Control Board PWA 17 7351054 Power Supply 24V DC 18 7155115 Cover Brinewell 19 7338145 Brinewell 7332204 Brinewell Mounting Hardware Kit includes Key Nos 20 22 20 Wing Nut...

Page 24: ...24 Valve Exploded View 51 50 52 53 55 56 59 58 57 60 61 66 67 62 63 64 68 69 70 71 72 73 74 75 65 76 77 79 78 80 81 82 Wear Strip Seal Cross section View 83 84 85 86 87 88 89 90 54 70 91...

Page 25: ...O Rings See Key No 72 1 ea of Key Nos 73 74 73 Turbine Support Shaft 74 Turbine 75 7082053 Valve Body 76 7081201 Retainer Nozzle Venturi 77 7342649 O Ring 6 4 x 9 5 mm pack of 2 78 1202600 Nut Ferrule...

Page 26: ...at the water treatment system is not damaged as the result of any unusual force of nature such as but not limited to flood hurri cane tornado or earthquake Warrantor is excused if failure to perform i...

Reviews: