Programming the Water Treatment System

FIG. 19

SET WATER HARDNESS NUMBER

1

. Press the SELECT button once again to display a

flashing “25” and the word “HARDNESS”.

2

. Press the 

p

UP or 

q

DOWN buttons to set your

water’s hardness number.

NOTE:

If your water supply contains iron, compen-

sate for it by adding to the water hardness

number.  For example, assume your water is

20 gpg hard and contains 2 ppm iron.  Add 5

to the hardness number for each 1 ppm of

iron.  In this example, you would use 30 for

your hardness number.

                                           20 gpg hardness

      2 ppm iron x 5 = 10    +10

                    (times)            30 HARDNESS NUMBER

NOTE:

If you use potassium chloride (KCl) salt

instead of sodium chloride (NaCl) salt in this

softener, increase the hardness setting by

25%.  For example, if you will be using KCl

and your water supply’s hardness is 20 gpg,

set the softener to 25 gpg.

SET RECHARGE (REGENERATION) TIME

Your demand water treatment system will automati-

cally regenerate when it needs to, based on water

usage.  The time of day that the automatic recharge

cycle begins may be changed as follows:

1

. Press the SELECT button once again to display a

flashing “2:00AM” and the words “SET RECHARGE

TIME”.  This is a good time for the recharge to start

in most households, because water is not in use.

FIG. 20

SET SALT LEVEL

The water treatment system has a low salt indicator

light to remind you to refill the storage tank with salt.

NOTE:

You must set salt level each time salt is added

to the water softener.

To set this monitor system:

1

. Lift the salt lid and level the salt in the storage tank.

2

. The salt level scale, on the brinewell inside the

tank, has numbers from 0 to 8 (See Fig. 21).

Observe the highest number the leveled salt is at,

or closest to.

3

. Press the SELECT button to display the words

“SET SALT LEVEL”.

4

. Press the 

p

UP or 

q

DOWN buttons until the num-

ber on the screen corresponds to the salt level.  At

level 2 or below, the “Low Salt" indicator light will

flash.  If you wish to turn this feature off, press the

q

DOWN button past 0, and the word “OFF” flash-

es in the display.

5

. Press the SELECT button once more to complete

the initial programming.  The current time of day

will show in the display.

2

. If you want to change the recharge start time,

press the 

p

UP or 

q

DOWN buttons until the

desired time shows.  Be sure AM or PM is correct.

FIG. 21

LEVEL

SALT

Salt

Level

Brine-

well

Num -

bers

Summary of Contents for EPHY

Page 1: ...r visit www ecopure com When you call please be prepared to provide the model and serial number of your product found on the rating decal located on the rim below the salt lid hinges System tested and...

Page 2: ...perated at a sustained maximum service flow rate greater than its listed rating This system has been proven to deliver soft water for at least ten continuous minutes at the rated service flow rate The...

Page 3: ...vice Flow Rate 6 5 gpm 24 6 lpm Amount of High Capacity Ion Exchange Resin 0 94 cu ft 26 6 liters Pressure Drop at Rated Service Flow 12 8 psig Water Supply Max Hardness 95 gpg Water Supply Max Clear...

Page 4: ...nly grounded and properly protected by an overcurrent device such as a circuit breaker or fuse Do not use this system to treat water that is microbiologically unsafe or of unknown quality without adeq...

Page 5: ...icles After the water stands for a period of time the particles settle to the bottom of the container Generally these irons are removed from water by filtra tion Chlorination is also recommended for b...

Page 6: ...tem close to the water supply inlet and upstream of all other plumbing connections except outside water pipes Outside faucets should remain on hard water to avoid wasting treated water and salt A near...

Page 7: ...ystem not included can be purchased and assembled as shown in Figure 8 Bypass valves allow you to turn off water to the system for mainte nance if needed but still have water in house pipes Pipe fitti...

Page 8: ...d level surface IMPORTANT Do not place shims directly under the salt storage tank to level the system The weight of the tank when full of water and salt may cause the tank to fracture at the shim 2 Vi...

Page 9: ...tment system valve inlet side NOTE Inlet and outlet are marked on the water treat ment system valve Trace the water flow direc tion to be sure hard water is to inlet IMPORTANT Be sure to fit align and...

Page 10: ...d be sure all wiring is away from the valve gear and motor area which rotates during regenerations 1 Plug the water softener s power supply into an elec trical outlet that is not controlled by a switc...

Page 11: ...sanitiz ing bleach into and through the water softener Any air remaining in the unit is purged to the drain 4 After the recharge has completed fully open a cold water faucet downstream from the softe...

Page 12: ...nected to electrical power the light on the control panel will operate as follows Light flashing with the time of day shown in the display The salt monitor system indicates a low salt level and needs...

Page 13: ...on once again to display a flashing 2 00AM and the words SET RECHARGE TIME This is a good time for the recharge to start in most households because water is not in use FIG 20 SET SALT LEVEL The water...

Page 14: ...the screen When completed full water treatment capacity is restored RECHARGE NOW initiated FIG 22 RECHARGE TONIGHT initiated FIG 23 FIG 26 FIG 25 FIG 24 CLEAN FEATURE This feature is beneficial on wa...

Page 15: ...ault setting To change this setting 1 Press and hold the SELECT button until the screen in Figure 24 is displayed 2 Press the SELECT button three times so that 12 hr or 24 hr flashes in the display Se...

Page 16: ...age level lower and to refill more often to avoid salt bridging Recommended Salt Nugget pellet or coarse solar salts with less than 1 impurities Salt Not Recommended Rock salt high in impurities block...

Page 17: ...e water level in the tank This will also assure that the system is completely recharged and ready to provide softened water again Check the water level in the tank by look ing down the brinewell If th...

Page 18: ...Contact a licensed plumber 6 Brine float dirty or broken Clean or replace Brine Valve Float Assembly 7 Leak between valve and resin tank Replace o rings between resin tank and valve Water hard some t...

Page 19: ...water is in contact with the salt and not separated by a salt bridge See Breaking A Salt Bridge section 5 While in this diagnostic screen the following infor mation is available and may be beneficial...

Page 20: ...ing or brine valve riser pipe 2 After observing fill press the RECHARGE button to move the system s valve into the brine position A slow flow of water to the drain will begin Verify brine draw from t...

Page 21: ...21 Notes...

Page 22: ...22 8 7 6 5 Water Treatment System Exploded View 27 26 28 15 16 12 18 19 20 11 22 23 24 25 8 6 3 9 10 7 Valve Assembly See Pages 24 25 for parts 5 2 1 21 4 14 13 17...

Page 23: ...16 7331834 Repl Electronic Control Board PWA 17 7351054 Power Supply 24V DC 18 7155115 Cover Brinewell 19 7338145 Brinewell 7332204 Brinewell Mounting Hardware Kit includes Key Nos 20 22 20 Wing Nut...

Page 24: ...24 Valve Exploded View 51 50 52 53 55 56 59 58 57 60 61 66 67 62 63 64 68 69 70 71 72 73 74 75 65 76 77 79 78 80 81 82 Wear Strip Seal Cross section View 83 84 85 86 87 88 89 90 54 70 91...

Page 25: ...O Rings See Key No 72 1 ea of Key Nos 73 74 73 Turbine Support Shaft 74 Turbine 75 7082053 Valve Body 76 7081201 Retainer Nozzle Venturi 77 7342649 O Ring 6 4 x 9 5 mm pack of 2 78 1202600 Nut Ferrule...

Page 26: ...at the water treatment system is not damaged as the result of any unusual force of nature such as but not limited to flood hurri cane tornado or earthquake Warrantor is excused if failure to perform i...