![Eco Pure EPHS Installation And Operation Manual Download Page 3](http://html1.mh-extra.com/html/eco-pure/ephs/ephs_installation-and-operation-manual_4009600003.webp)
3
Specifications & Performance Claims
*
Capacity to reduce clear water iron is substantiated by laboratory test data. State of Wisconsin
requires additional treatment if water supply contains clear water iron exceeding 5 ppm.
§ From independent laboratory test data.
This system conforms to NSF/ANSI Standards 42 & 44 for the specific performance claims as
verified and substantiated by test data.
Variable Salt Dose:
The salt dose is selected by the electronic controls at regeneration time
based on the amount needed.
SPECIFICATIONS
Model EPHS
Model Code
EPHS
Rated Softening Capacity (Grains @ Salt Dose)
14,000 @ 2.9 lbs.
29,800 @ 9.3 lbs.
35,600 @ 15.6 lbs.
Rated Efficiency (Grains/Pound of Salt @ Minimum Salt Dose)
4,230 @ 2.9 lbs.
Water Used During Regeneration @ Minimum Salt Dose
3.7 gal. / 1,000 grains
Total Water Used Per Regeneration @ Maximum Salt Dose
58.6 gallons
Rated Service Flow Rate
8.0 gpm
Amount of High Capacity Ion Exchange Resin
0.98 cu. ft.
Pressure Drop at Rated Service Flow
8.4 psig
Water Supply Max. Hardness
100 gpg
Water Supply Max. Clear Water Iron
3 ppm*
Water Supply Pressure Limits (minimum / maximum)
20 - 125 psi (137.9 - 861.8 kPa)
Water Temperature Limits (minimum / maximum)
40 - 120 °F (5 - 49 °C)
Minimum Water Supply Flow Rate
3 gpm (11.4 lpm)
Maximum Drain Flow Rate
2.0 gpm (7.6 lpm)
0.50 ppm
0.75 ppm
Rated Capacity at Chlorine Concentration** of: 1.0 ppm
1.5 ppm
2.0 ppm
2,280,000 gal. (8,630,000 liters)§
1,520,000 gal. (5,750,000 liters)§
1,140,000 gal. (4,310,000 liters)§
760,000 gal. (2,870,000 liters)§
570,000 gal. (2,150,000 liters)
§
PERFORMANCE CLAIMS
Contaminant
Influent Challenge Level
Maxiumum Allowable
Product Water Level
Barium
10 ±10% mg/L
2.0 mg/L
Radium 226/228
25 pCi/L
5 pCi/L
Substance
Influent Challenge Level
Reduction Requirement
Chlorine
2.0 ±10% mg/L
50%
Questions? Call Toll Free 1-800-693-1138
or visit
www.ecopure.com
When you call, please be prepared to provide the model and serial number,
found on the rating decal, typically located on the rim below the salt lid hinges.