set the  comfort  temperature  higher  than the  room  temperature;

  it  will  cycle  the  unit (burners 

and  fan)  to  keep  the  area  heated  at  a  constant  temperature.    For  a  digital  thermostat  set  the 
temperature  higher  than  the  room  temperature  to  call  for  heat.  For  programmable  thermostats 
follow the instructions provided with the thermostat to set the program of your choice to switch on 
and  switch  off the  unit  automatically  at  the  pre-set  day,  time,  and  temperature.  For mounting the 
thermostats, the following instruction could be helpful- 

 

The  thermostat  should  be  mounted  on  a  draught  free  internal  wall,  out  of  direct  sunlight  for  best 
operation. 
Because the thermostat is sensitive to heat, devices such as electrical equipment, lamps and TV 
should not be placed near it.   
The thermostat may accumulate lint and dust which may affect its accuracy and therefore should 
be checked and cleaned annually. 

 
Maintaining your heating system:  

The 

Super Star

 ducted heating system has been designed for low maintenance throughout its life.  

Untrained  personnel  can  perform  basic maintenance  functions,  like  cleaning  and replacing  return 
air  filters,  if  fitted.    Filters  should  be  removed  for  cleaning  at  regular  intervals,  preferably  each 
month during  heating  season.    A  blocked  filter  will  restrict  airflow  and  possibly  overheat  the  heat 
exchanger and 

motor windings, thus greatly affecting your heater’s life span and performance, and 

may  void  warranty.   

Any  servicing  or  repairs  to  the  heater  must  be  performed  only  by  a 

qualified or by an Eco Pacific factory trained service technician. 

 
Outlet registers:

  

It is important to keep the following minimum number of registers or ceiling diffusers open all the 
time to prevent overheating of the appliance: 
 
Models  

 

 

                     keep open minimum no. of outlets. 

Super Star, SS512/HB412 

                                   2 

Super Star, SS516/HB416 

 

 

            3 

Super Star, SS520/HB420 

 

 

 

Super Star, SS525/HB425 

 

 

 

Super Star, SS530/HB430                                         6 
 
Inadequate  return  air  due  to  dirty  filters,  placement  of  furniture  over  circulating  air  registers  or 
restricting the circulating air passageway can cause excessive heat exchanger  temperatures and 
reduce the heat

er’s life span.  

 
 

Note:

 

The  use  of  filters  on  the  supply  air  registers/diffusers  are  not  allowed  as  these  will 

restrict the supply air ducting and will overheat the heat exchanger leading to a reduced life 
of  the  heater.  Please  be  aware  that  using

 

filters  on  supply  air  registers  would  void  the 

warranty.   However,  you  can  put  a filter  in  the  return  air  grill  and make  sure  it  is  regularly 
cleaned.

 

 

Abnormal operation:

  

Should any of the following characteristics occur, do not use the heating, contact your local service 
agent or the gas authority immediately: 

  Smell of gas, 

  Unusual odours from outlet resisters, 

  Smoke or fumes from outlet registers, 

  Excessive or unusual noise emanating from the appliance. 

 
Please ensure that where the heater is in the roof space the blow-in loose fill insulation material is 

Summary of Contents for Super Star SS512

Page 1: ...c The company will not be able to accept any responsibility for any problems if occurs due to faulty installation Installers should hand over this booklet to the customer upon installation with verbal...

Page 2: ...familiarise yourself with the operation of the system so please read the instructions that follow After that store these instructions in a safe place for future reference If you have any concerns abou...

Page 3: ...r sustain flame Check that the flame sensor is connected on to the board and positioned properly above the burner port 4 flashes High limit or manual overheat switch opened wait until the auto switch...

Page 4: ...nd motor windings thus greatly affecting your heater s life span and performance and may void warranty Any servicing or repairs to the heater must be performed only by a qualified or by an Eco Pacific...

Page 5: ...hat date This warranty includes labour in the Melbourne Metropolitan area only but in other areas parts supply only The warranty is conditional upon appliance being installed in accordance with the ma...

Page 6: ...it model serial number date installed and the trouble experienced The following checks should be undertaken before making a request for service a Unit is plugged into power point with correct polarity...

Page 7: ...inutes before rising in the morning or getting home in the evening And of course don t forget to turn the entire system completely off if you are going away on holidays Close windows and doors in heat...