17
COMMISSIONING AND
HANDOVER
APPLIANCE CHECK
Please check that all components are correctly
assembled and working correctly.
Ensure the Door Catch mechanism is adjusted
correctly and the 12mm Rope Seals around the door
are air tight and sealing.
Ensure the Air Controls are working correctly.
Eco Ideal Stoves recommend that you carry out a
smoke draw test to check the soundness of the
chimney/flue system and seals:
Place a Smoke Pellet in the centre of the Grate,
ensure that all of the Air Controls are fully open and
close the Door.
The smoke should now be drawn up the chimney
and you should be able to see it exit from the
chimney/flue terminal.
We recommend that you do this test with all of the
windows and doors, to the room where the
appliance is fitted, closed.
If there any adjoining room(s) that have an Extractor
Fan fitted, open the adjoining door to ensure that
the chimney/flue system is not compromised when
the fan is operating.
If there is a ceiling fan fitted in the room please
operate it and ensure that it does not affect the
operation of the chimney/flue system.
If any of these tests fail, please re-check the
suitability of the chimney/flue system together
with the ventilation.
A small fire can now be lit and allow the appliance to
heat up slowly ensuring that no products of
combustion enter into the room. When the
appliance has reached working temperature open
the Door and carry out a spillage test using a smoke
match around the door opening.
If there is excessive spillage please allow the
appliance to cool and then re-check the
chimney/flue system and ventilation.
Do not run the stove at full output for at least 24
hours.
On completion of the commissioning:
Upon completion, allow a suitable period of time for
any fire cement and mortar to dry out. A small fire
may then be lit and checked to ensure the smoke
and fumes are taken from the stove up the chimney
and emitted safely to atmosphere. Do not run the
stove at full output for at least 24 hours.
Please instruct the user on the safe operation of this
appliance, how the controls work and basic
maintenance requirements.
Ensure that the operating instructions and appliance
tools are left with the customer and the check lists
have been filled out correctly.
Please advise the customer on the correct use of the
appliance with the fuels likely to be used on the
stove and warn them to use only the recommended
fuels for the stove.
Advise the user on what to do should smoke or
fumes be emitted from the stove.
The user should be warned to use a fireguard to BS
6539 in the presence of children, aged and/or infirm
persons.
Eco Ideal Stoves also recommend that a CO alarm is
fitted into the room where the appliance is located.