background image

2

Fill Pump with water to prime: Ensure pump body is filled with water to discharge. 

Motor’s Electrical Settings: Set motor to proper voltage.  

 

 

Help Line: Call 1-877-326-3561 for assistance

STOP

Before you start

For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561

GENERAL SAFETY

SAFETY LABELS

Important Safety Instructions Carefully read and follow all safety instructions in this manual and on pump. 

SAVE THESE INSTRUCTIONS – This manual contains important instructions that should be followed during installation, 

operation, and maintenance of the product. Save this manual for future reference.

 

This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the  

 

following signal words and be alert to the potential for personal injury!

 

 

Indicates a hazard which, if not avoided,  

 

 

will result in death or serious injury.

 

 

Indicates a hazard which,if not avoided,  

 

 

could result in death or serious injury.

 

 

Indicates a hazard which,if not avoided,  

 

 

could result in minor or moderate injury.

 

 

NOTICE

 indicates practices not related to personal injury.

Keep safety labels in good condition. Replace missing or 

damaged safety labels.

•  Keep pump equipment out of the reach of children! Failure  

  to follow the directions given could cause serious risk to  

  individuals or objects.

•   DO NOT work on pump until power is disconnected. 

•   DO NOT cut off ground pin or use an adapter fitting.

•   DO NOT use an extension cord. 

•  DO NOT use this pump for water pressure booster appli- 

  cations. The pump housing is rated for 55 PSI MAX. 

•   The pump power cord should be connected to a sepa-  

  rately fused, grounded line with a minimum amp  

 

  capacity listed on page 6. It can be connected to a non- 

  fused breaker at the recommended amperes.

•  ELECTRICAL PRECAUTIONS - Before servicing the    

  pump, always shut off the main power breaker and then  

  unplug the pump. Make sure you are not standing in    

  water and are wearing insulted protective shoes under   

  flood conditions. Contact your local electric company or  

  a qualified licensed electrician for disconnecting electrical  

  service prior to pump removal.

•  Follow all local electrical and safety codes, as well as    

  the National Electrical Code (NEC) and the Occupational  

  Safety and Health Act (OSHA)

•  Replace damaged or worn wiring cord immediately. 

•  Do not kink power cable and never allow the cable to    

  come in contact with oil, grease, hot surfaces, or  

 

 chemicals.

•  Wire motor to correct supply. See motor nameplate and  

  wiring diagrams and check voltage of power supply.

•  Unit must be securely and adequately electrically ground- 

  ed. This can be accomplished by wiring the unit to a    

  ground metal-clad raceway system or by using a separate  

  ground wire connected to the bare metal of the motor    

  frame or other suitable means.

•  Do not disassemble the motor housing. This pump has  

  no repairable internal parts and disassembling may cause  

  leakage or dangerous electrical wiring issues.  

•  Make certain the electrical power source is adequate for  

  the requirements of the pump.

•  Install pressure relief valve in the discharge pipe. Release  

  all pressure on system before working on any component. 

•  The following may cause severe damage to pump and will  

  void the warranty. 

  - Using an extension cord. 

  - Cutting off the ground pin or using an adapter fitting. 

  - Working on the pump or switch while plugged in. 

  - Removing motor housing, unscrewing impeller or  

    otherwise removing impeller seal

  - Running the pump continuously.

  - Pumping chemicals, corrosive liquids or anything beside  

    clean, clear water.

  - Pumping gasoline or other flammable liquids. 

•  This pump is only to be used for water systems. 

•  Protect the power cable from coming in contact with    

  sharp objects. 

•  Do not run pump dry.

•  Pump and plumbing must be full of water before startup. 

•  Do not pump water which contains sand, mud, silt or    

 debris.

•  Be careful when touching the exterior of a motor. It may  

  be hot enough to be painful or cause injury.

•  Do not allow pump or any system component to freeze.  

  To do so will void the warranty.

continued

Summary of Contents for EFLS10P

Page 1: ...Owner s Manual Thermoplastic Sprinkler Pumps General Safety 2 Installation 3 5 Electrical 6 Operation 7 Troubleshooting 8 Repair Parts 9 Warranty 10 EFLS10P 15P EFLS20P TABLE OF CONTENTS...

Page 2: ...n water and are wearing insulted protective shoes under flood conditions Contact your local electric company or a qualified licensed electrician for disconnecting electrical service prior to pump remo...

Page 3: ...operates at high temperature and will be too hot to touch It is protected from heat dam age during operation by an automatic internal cutoff switch Before handling pump or motor stop motor and allow...

Page 4: ...Surface Water Applications Figure 3A and 3B A Vertical from Surface Water to Pump 1 Foot Valve with Strainer attached to PVC pipe 2 Install check valve in horizontal pipe B Horizontal from Surface Wat...

Page 5: ...olt pump to solid level foundation 2 Support all piping connected to pump 3 Use plastic safe joint compound on all male threads being attached to the pump 4 Tighten joints hand tight plus 1 1 2 turns...

Page 6: ...r before connecting to electrical power supply Failure to ground motor can cause severe or fatal electrical shock hazard 3 Supply voltage must be within 10 of nameplate voltage Incorrect voltage can c...

Page 7: ...no water is produced within 10 minutes stop pump release all pressure remove priming plug refill and try again Risk of explosion and scalding NEVER run pump against closed discharge To do so can boil...

Page 8: ...Piping is too small in size Pump not being supplied with enough water Clamp loose CORRECTIVE ACTION Be sure switch is on Replace fuse or reset circuit breaker DISCONNECT POWER Replace starting switch...

Page 9: ...ts or assistance call ECO FLO Customer Service at 1 877 326 3561 REPAIR PARTS EFLS10P 15P 1 HP and 1 1 2 HP Part Quantity Part Number Description 1 1 EFLS10001 O RING 2 1 EFLS10002 O RING EFLS20P 2 HP...

Page 10: ...ly take corrective action as promptly as reasonably pos sible No requests for service will be accepted if received more than 30 days after the warranty expires Warranty is not transferable and does no...

Page 11: ...ires Bombas de pl stico para rociadores de c sped Informaci n de seguridad 12 Instalaci n 13 15 Conexiones el ctricas 16 Operaci n 17 Soluci n de problemas 18 Repuestos 19 Garant a 20 EFLS10P 15P EFLS...

Page 12: ...CEN y la Ley de Seguri dad y Salud Ocupacional OSHA Reemplace inmediatamente los cables da ados o desgastados No retuerza el cable de energ a y nunca permita que el cable haga contacto con aceite gra...

Page 13: ...r la bomba o el motor detenga el motor y deje que se enfr e durante 20 minutos 13 INSTALACION INSTALACI N DE LA TUBER A DEL POZO Aviso se recomienda que la bomba se instale en un lugar bien ventilado...

Page 14: ...erficial a la bomba 1 V lvula de pie con filtro conectado a la tuber a de PVC 2 Instale la v lvula de retenci n en la tuber a horizontal B Horizontal del agua superficial a la bomba 1 Conecte la v lvu...

Page 15: ...bado por un indicador de presi n Esto ayudar a calibrar las zonas resolver problemas y cumplir los valores del cuadro de desem pe o de la bomba AVISO Para tramos de tuber a horizontales largos instale...

Page 16: ...es apague el motor antes de trabajar en las conexiones el ctricas 2 Conecte el motor a tierra antes de conectar la fuente de energ a el ctrica Si no se hace la conexi n a tierra del motor se puede gen...

Page 17: ...no sale agua en 10 minutos pare la bomba alivie la presi n retire el tap n para cebado vuelva a llenar y trate otra vez PRECAUCI N 17 Figura 4 Llene la bomba antes de empezar Figura 5 No haga funciona...

Page 18: ...1 1 2 10 61 56 45 26 15 56 54 44 20 20 46 44 37 11 5 83 71 56 41 17 EFLS20P 2 10 77 67 54 36 8 15 76 65 50 32 20 75 62 48 28 MODEL HP 10 20 30 40 50 DISTANCE OF PUMP ABOVE WATER DISCHARGE PRESSURE Par...

Page 19: ...za Descripci n 1 1 EFLS10001 JUNTA T RICA 2 1 EFLS10002 JUNTA T RICA EFLS20P 2 HP Pieza Cantidad N mero de pieza Descripci n 1 1 EFLS20001 JUNTA T RICA 2 1 EFLS20002 JUNTA T RICA Para obtener repuesto...

Page 20: ...fecto El fabricante tomar luego la acci n correctiva tan pronto como sea razonablemente posible No se aceptar n solicitudes de servicio si se reciben m s de 30 d as despu s del vencimiento de la garan...

Page 21: ...ilisateur Pompe en plastique pour arroseurs de pelouse S curit g n rale 22 Installation 23 25 lectricit 26 Fonctionnement 27 D pannage 28 Pi ces de rechange 29 Garantie 30 EFLS10P 15P EFLS20P TABLE DE...

Page 22: ...locales ainsi que la norme lectrique am ricaine NEC et la loi sur l hygi ne et la s curit au travail OSHA Remplacez imm diatement un cordon d alimentation en dommag ou us Ne pincez pas le c ble d alim...

Page 23: ...frottement et r duisent l coulement de l eau vers la pompe Positionnez la pompe aussi pr s que possible de la source de l eau Utili sez aussi peu de coudes et raccords que possible Assurez vous que l...

Page 24: ...un clapet de pied avec cr pine sur le tuyau en PVC 2 Installez un clapet anti retour dans le tuyau horizontal B Tron on horizontal de la surface de l eau la pompe 1 Fixez un clapet de pied au tuyau en...

Page 25: ...as avec exc s 5 Remplacez le bouchon d amor age par un Cela va aider pour le calibrage de zones le d pan nage et le suivi de performance de la pompe AVIS En cas de longs tron ons horizontaux de tuyaut...

Page 26: ...er 1 Pour viter une commotion lectrique dangereuse ou mortelle coupez en amont l alimentation secteur allant au moteur avant d effectuer des connexions lectriques 2 Reliez le moteur la terre avant de...

Page 27: ...TENTION Amor age de la pompe AVIS L amor age veut dire l expulsion de tout l air du sys t me et le commencement de l attraction d eau depuis sa source Le terme ne concerne pas que le versement d eau d...

Page 28: ...ALIMENTATION SECTEUR puis remplacez le manostat R f rez vous aux instructions de c blage D BRANCHEZ L ALIMENTATION SECTEUR puis contr lez et resserrez tout le c blage R f rez vous aux instructions de...

Page 29: ...ce Description 1 1 EFLS10001 JOINT TORIQUE 2 1 EFLS10002 JOINT TORIQUE EFLS20P 2 CV R f de pi ce Quantit N de pi ce Description 1 1 EFLS20001 JOINT TORIQUE 2 1 EFLS20002 JOINT TORIQUE Pour des pi ces...

Page 30: ...suppos Le constructeur ex cutera ensuite une action corrective dans un d lai raisonnable Aucune demande au titre de la garantie ne sera accept e si elle est re ue plus de 30 jours apr s la date d expi...

Reviews: