background image

Smart 3pA  Page 7

2.4 Connecting the sensors to the transmitter

P

lug the three sensor cables into the transmitter on the underside of the transmitter. Remembering

which cable is plugged into each socket.

 (I.e. sensor 1 = Red etc.)

Press the release catch to remove the wall plate and use a double sided self-adhesive sticky pad
or screw (not supplied) to affix in a convenient position close to the cables being monitored.

Make sure the release catch in on the left hand side.

Fit 2 x AA Batteries into the transmitter making sure they are the right way round (see below)

Press and hold the square button on the transmitter while installing

the batteries to set it to 3 phase transmit mode

Once you have inserted the batteries you
should see the red light start to flash on
the Eco eye transmitter.

Clip the back onto the transmitter and
plug the sensors into the bottom of the
transmitter.

Summary of Contents for Smart 3pA Series

Page 1: ...Smart 3pA Page 1 Eco Eye Smart Commercial Smart 3pA 3 phase monitoring and recording Set up and Operating Instructions Efficient technology for today s world eco eye real time electricity monitors...

Page 2: ...5 Powering the display 2 6 Is it working 3 Using the Display 3 1 Real time or Predicted Mode 3 2 Accumulator 3 3 History How many Kilowatts used 4 Change Settings 4 1 Calibrating the temperature 4 2...

Page 3: ...tem for commercial premises and has the ability to log all the information you re seeing on the display to an MMC card and using our free computer program can be converted into cost and analysed in mo...

Page 4: ...tal current passing through them This is a simple job and involves no cutting or disturbing of any wiring or the need for a qualified electrician unless you feel uncomfortable removing electrical trun...

Page 5: ...the 3 live cables coming into that meter The sensors simply clip round each of the coloured cables Red Yellow and blue The black is the neutral In the picture below there are 2 cables for each phase...

Page 6: ...ot easily fit round the cables you re trying to monitor then you may be trying to attach it to an armoured or multi core cable The faces of the sensor must make a flat contact The sensors are designed...

Page 7: ...ied to affix in a convenient position close to the cables being monitored Make sure the release catch in on the left hand side Fit 2 x AA Batteries into the transmitter making sure they are the right...

Page 8: ...the green button bottom right to store Note Selecting the currency also inputs the most appropriate country specific value for voltage 2 6 Is it working If the sensor and transmitter are connected cor...

Page 9: ...ill see the arrow and P see left when you are in predicted mode 7 days history is stored on the monitor and can be accessed in Amps and Kilowatts by pressing the left arrow key The icon will change to...

Page 10: ...6 and then there will be a slight pause and it will continue with its regular 4 second flashes Reset to 3 phase mode by removing a battery and holding the square button on the transmitter while inser...

Page 11: ...during firmware upgrade H Low battery indicator I Used when setting Voltage J Good radio reception K See Trax manual L See Trax manual M See Trax manual N Big number is accumulated O Big number is ta...

Page 12: ...shock 8 IF IN ANY DOUBT regarding the installation of this product consult a qualified electrician before proceeding 7 Guarantee This Eco eye product is guaranteed for the period of one year from the...