Eco Air EPA-09CRN8 Owner'S Manual & Installation Manual Download Page 19

Other features

DRY operation

·  Press the  "MODE" button until the  "DRY" indicator 

   light comes on.     

·  The fan speed or the temperature cannot be 

   adjusted. The fan motor operates at LOW speed. 

NOTE:Keep windows and doors closed for the best 

dehumidifying effect. Do not put the duct to window.

FAN operation

·  Press the  "MODE" button until the"FAN " indicator  

   light comes on. 

·  Press the "FAN SPEED" button 

on 

the remote 

   controller to choose the fan speed. The temperature 

   can not be adjusted.

·  Do not put the duct to window.

AUTO operation(on some models)

·  When you set the air conditioner in AUTO mode, it 

   will automatically select cooling, heating(cooling 

   only models without), or fan only operation 

   depending on what temperature you have selected 

   and the room temperature.

·  The air conditioner will control room temperature 

   automatically round the temperature point set by 

   you.

·  Under AUTO mode, you can not select the fan speed.

 

HEAT operation(cooling only models without)

·  Press the  "MODE" button until the  "HEAT" indicator 

   light comes on. 

·  Press the  ADJUST buttons "+" or " - " to select your

   desired room temperature. The temperature can be 

   set within a range of 17°C~30°C/62°F~88°F (or 86°F).

·  Press the "FAN SPEED" button on the remote 

   controller to choose the fan speed.   

Wireless operation(on some models)

Used to initiate the wireless connection mode. For the 

first time to use wireless function, press the POWER 

button for 3 seconds to initiate the wireless connection 

mode . The LED DISPLAY shows 'AP' to indicate you can 

set wireless connection. If connection(router) is successful 

within 8 minutes, the unit will exit wireless connection 

mode automatically and the wireless indicator illuminates. 

If connection is failure within 8 minutes, the unit exits 

wireless connection mode automatically. After Wireless 

connection is successful, for some models you can 

press MODE and UP (+) buttons at the same time 

for 3 seconds to turn off Wireless function and the LED 

DISPLAY shows 'OF' for 3 seconds, press MODE button 

and UP(+) to turn on Wireless function and the LED 

DISPLAY shows 'O

n

' for 3 seconds. 

NOTE: When you restart the wireless function, it  may 

take a period of time to connect to the network

automatically. 

NOTE: Under AUTO mode, both the AUTO mode and 

the actual operation mode indicator lights illuminate 

for some models.  

SLEEP/ECO operation

This feature can be activated from the remote control

ONLY. To activate SLEEP feature, the set temperature

will increase(cooling) or decrease(heating) by 1°C/2°F

(or 1°F) in 30 minutes. The set  temperature will then

increase(cooling) or decrease(heating) by another 1°C

/2°F (or 1°F) after an additional 30 minutes. This new

temperature will be maintained for 7 hours before it 

returns to the originally selected temperature. This 

ends the Sleep mode and the unit will continue to 

operate as originally programmed.

NOTE: This feature is unavailabe under FAN or DRY 

mode. 
FOLLOW ME/TEMP SENSING feature(on some models)

NOTE:This feature can be activated from the remote

control ONLY. The remote control serves as a remote  

Constatnt Fan button(On some models) 

In cooling or Dry mode, press the button for

3 seconds to turn on or off the constant fan 

function. When the function is turned on, the

constant fan light will illuminate, identifying 

the fan continuous run for cooling. When the 

function is turned off, the constant fan light 

will go out, identifying the fan cycle run with 

compressor stop.    

 Page 19

 Operating

Instructions

FRESH operation(on some models)

Press MODE and DOWN (-) buttons at the same time 

for 3 seconds to initiate FRESH feature and the FRESH 

light illumiantes on some models, the LED DISPLAY 

shows 'O

n

' for 3 seconds. The ion generatoris energized 

and will help to purify the air inside. Press it for 3 

seconds again to stop the FRESH feature and the FRESH 

light turn dark on some models, the LED DISPLAY shows 

'OF' for 3 seconds for some units.

Summary of Contents for EPA-09CRN8

Page 1: ...ner Owner s Manual Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference 55 54 EPA 09CRN8 R32 22 2 kg 48 9 lb 10 108 9 000 51 5 ...

Page 2: ...recautions Air Filter Cleaning Troubleshooting Tips Unit Cleaning Store the unit when not in use Preparation Design Notice Energy Rating Information Ambient Temperature Range For Unit Operating Exhaust Hose Installation Choosing The Right Location Tools Needed Accessories Window Installation Kit Installation Troubleshooting Tips 03 11 11 12 12 12 12 13 13 14 16 18 18 19 21 21 21 21 22 ...

Page 3: ...g is grounded and has the appropriate voltage The power cord is equipped with a three prong grounding plug to protect against shock Voltage information can be found on the nameplate of the unit Your unit must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker the fuse or circuit bre...

Page 4: ...hould be supervised to ensure that they do not play with the appliance Children must be supervised around the unit at all times be applicable for other countries except the European Countries If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard CAUTION Disconnect the power if strange sounds smell or smoke ...

Page 5: ...scapes endangers your health when hazar do us substances leak into the ground water and find their way into the food chain Do not use hazardous chemicals to clean or come into contact with the unit Do not use the unit in the presence of inflammable substances or vapour such as alcohol insecticides petrol etc Always transport your air conditioner in a vertical position and stand on a stable level s...

Page 6: ...Ne pas percer ni bruler Attention les frigorigènes peuvent être inodores Please follow the instruction carefully to handle install clear service the air conditioner to avoid any damage or hazard Flammable Refrigerant R32 is used within air conditioner When maintaining or disposing the air conditioner the refrigerant R32 or R290 shall be recovered properly shall not discharge to air directly No any...

Page 7: ...nside the package will not cause a leak of the refrigerant charge The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations 3 General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out Work in confined spaces shall be avoided The area around the workspace shall be s...

Page 8: ...cuit is being used the secondary circuit shall be checked for the presence of refrigerant Marking to the equipment continues to be visible and legible Markings and signs that are illegible shall be corrected Refrigeration pipe or components are installed in a position where they are unlikely to be exposed 1 During repairs to sealed components all electrical supplies shall be disconnected from the ...

Page 9: ...he following leak detection methods are deemed acceptable for systems containing flammable refrigerants Electronic leak detectors shall be used to detect flammable refrigerants but the sensitivity may not be adequate or may need re calibration Detection equipment shall be calibrated in a refrigerant free area Ensure that the detector is not a potential source of ignition and is suitable for the re...

Page 10: ...b Isolate system electrically c Before attempting the procedure ensure that Mechanical handling equipment is available if required for handling refrigerant cylinders All personal protective equipment is available and being used correctly The recovery process is supervised at all times by a competent person Recovery equipment and cylinders conform to the appropriate standards d Pump down refrigeran...

Page 11: ...s In addition a set of calibrated weighing scales shall be available and in good working order Hoses shall be complete with leak free disconnect couplings and in good condition Before using the recovery machine check that it is in satisfactory working order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant releas...

Page 12: ...o the portable air conditioners themselves The unit with 3 meters extended exhaust duct is running by using 2 exhaust ducts Diameter 150mm Length 1 5m Diameter 130mm Length 1 5m The Energy rating and noise information for unit with 3 meters extended exhaust duct is not assessed For some models NOTE We recommend that operating the unit at room temperature below 35 C Since there is a risk that the u...

Page 13: ...determine the square footage of the room you want to cool by multiplying the room length by its width You also need to know the air conditioner s BTU British Thermal Unit rating which indicates the amount of heat it can remove from a room A higher Why is the cooling capacity lower on newer models than on older units number means more cooling power for a larger room Be sure you are comparing only n...

Page 14: ...Hose 1 pc 1 pc Window Slider Adaptor Power Cord Buckle O N O F F T E M P S H O R T C U T T IM E R O N T IM E R O F F M O D E FA N S LE E P S W IN G LE D 1 set 1 pc Window Slider B Remote Controller and Battery only for remote control models 1 pc Wall Exhaust Adaptor A only for wall installation models 2 pc Foam Seal A Adhesive 1 pc Wall Exhaust Adaptor B with cap only for wall installation models ...

Page 15: ...liders once they are adjusted to the Proper length Window slider A Window slider B Bolt Window slider A Window slider B Window slider C Bolts Step Two Install the Exhaust hose assembly to the unit Push the Exhaust hose into the airoutlet opening of the unit along the arrow direction MODEL B MODEL A MODEL C 1 2 Bolt Bolt Bolt 1 2 3 1 2 1 2 3 Bolt Bolt Bolt 1 2 3 4 Bolt Bolt Bolt 1 4 Bolt Window Sli...

Page 16: ...sash and frame as shown Foam seal B Adhesive type shorter Foam seal A Adhesive type Or Or Window slider A Window slider B if required Foam seal C Non adhesive type 3 Cut the non adhesive foam seal C strip to match the width or height of the window Insert the seal between the glass and the window frame to prevent air and insects from getting into the room 2 Insert the window slider assembly into th...

Page 17: ... actual shape shall prevail NOTE Cover the hole using the adaptor cap when not in use max 120cm or 47 inch min 30cm or 12 inch Expansion anchor position Adaptor cap Wall Exhaust Adaptor B Or 5 Insert the window slider adaptor into the hole of the window slider Type 2 Wall Installation For some models 1 Cut a 125mm 4 9inch hole into the wall for the Wall Exhaust Adaptor B 2 Secure the Wall Exhaust ...

Page 18: ...r error on some models E4 Display panel communication error EC Refrigerant leakage detection malfunction on some models Shows protection code P1 Bottom tray is full Connect the drain hose and drain the collected water away If protection repeats call for service NOTE When one of the above malfunctions occurs turn off the unit and check for any obstructions Restart the unit if the malfunction is sti...

Page 19: ...ss MODE and UP buttons at the same time for 3 seconds to turn off Wireless function and the LED DISPLAY shows OF for 3 seconds press MODE button and UP to turn on Wireless function and the LED DISPLAY shows On for 3 seconds NOTE When you restart the wireless function it may take a period of time to connect to the network automatically NOTE Under AUTO mode both the AUTO mode and the actual operatio...

Page 20: ...e sure the hose is secure so there are no leaks Direct the hose toward the drain making sure that there are no kinks that will stop the warter flowing Place the end of the hose into the drain and make sure the end of the hose is down to let the water flow smoothly When the continuous drain hose is not used ensure that the drain plug and knob are installed firmly to prevent leakage Continuous drain...

Page 21: ...he unit using a damp lint free cloth and mild detergent Dry the unit with a dry lint free cloth Drain the unit s water collection tray according to the instructions in the following section Run the appliance on FAN mode for 12 hours in a warm room to dry it and prevent mold Turn off the appliance and unplug it Clean the air filter according to the instructions in the previous section Reinstall the...

Page 22: ...an to inspect the unit and top off refrigerant Decrease the set temperature Make sure all windows and doors are closed Double check the cooling area Turn off the unit disconnect the hose check for blockage and reconnect the hose Remove the heat sources if possible The unit is noisy and vibrates too much The unit makes a gurgling sound The ground is not level Place the unit on a flat level surface ...

Page 23: ......

Page 24: ...ns are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please check for the latest version ...