background image

Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner

may be reduced and the air conditioner may stop running.

Clean the air filter periodically, otherwise cooling or heating performance may be reduced.

Do not operate unit with horizontal louvre in closed position.

ADJUSTING AIR FLOW DIRECTION

6

Lever

   Adjust the air flow direction properly otherwise, it 
   might cause discomfort or  cause uneven room 
   temperatures.
   Adjust the horizontal louver using the remote 
   controller.
   Adjust the vertical louver manually.

  

To set the vertical air flow(Up--Down) direction

   

Perform this function while the unit is in operation.

   Use the remote controller to adjust the air flow 
   direction. The horizontal louver can be moved at 

O

   a angle of 6  for each press or set to move up 
   and down automatically. Please refer to the   
   REMOTE CONTROLLER OPERATION MANUAL  
   for details.

   

   

To set the horizontal air flow direction (left - right)

Adjust the vertical louver manually using the lever 
on the left or right side of the vertical louver arm 
(Depending on model). Take care not to catch 
fingers on the fan, horizontal louver or to damage 
vertical louvers. When the air conditioner is in 
operational and the horizontal louver is  in a specific 
position, move the lever at left (or right, depending
 on model) end of the air outlet to the desired position.

    

Do not operate the air conditioner for long periods with the 
air flow direction set downward in cooling or dry mode. 
Otherwise, condensation may occur on the surface of the 
horizontal louver causing moisture to drop on to the floor or 
on furnishings.
Do not move the horizontal louver manually. Always use the 
DIRECTION/SWINGbutton. If you move this louver 
manually, it may malfunction during operation. If the louver 
malfunctions, stop the air conditioner once and restart it.
When the air conditioner is started immediately after it was 
stopped, the horizontal louver might not move for 
approximately 10 seconds.
Open angle of the horizontal louver should not be set too 
small, as COOLING or HEATING performance may be 
impaired due to too restricted air flow area.
Do not operate unit with horizontal louver in closed position.
When the air conditioner is connected to power (initial 
power), the horizontal louver may generate a sound for 10 
seconds, this is a normal operation.

CAUTION

!

,,

,,

Summary of Contents for ECO2406SD

Page 1: ...view the chart of Troubleshooting Tips before calling your service engineer Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a lit...

Page 2: ...ke back the old appliance for disposal when you replace with a new product C Old products contain valuable resources which should be recycled as scrap metal Wild disposal of waste in forests and lands...

Page 3: ...ems in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first you may not need to call for service Contact an authorised service technician for repair or maintenance o...

Page 4: ...earthing may cause electric shock It may cause fire and electric shock It may cause fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause e...

Page 5: ...s food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the u...

Page 6: ...ing sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock 3 When cleaning the unit first make sure th...

Page 7: ...Remote controller 10 Manual control button 11 Connecting pipe drain hose 12 Air inlet side and rear 13 Air outlet Indoor unit Outdoor unit On Of f Sle ep Fan Sw ing Air Dire ction Tim er On Tim er Of...

Page 8: ...conds later B It displays the room temperature when the air conditioner is in FAN only operation C Displays the malfunction code or protection code FREQUENCY indicator This indicator appears only when...

Page 9: ...ake care not to catch fingers on the fan horizontal louver or to damage vertical louvers When the air conditioner is in operational and the horizontal louver is in a specific position move the lever a...

Page 10: ...g cooling heating cooling only type without or AUTO operation the air conditioner will automatically increase cooling or decrease heating 1 per hour for the first 2 hours then hold steady for the next...

Page 11: ...fore cleaning WARNING MAINTENANCE Filter Handle 8 Use a dry cloth to wipe the indoor unit and remote controller A cloth dampened with cold water may be used on the indoor unit if it is very dirty The...

Page 12: ...tion If you plan to idle the unit for a long time perform the following 1 Operate the fan for about half a day to dry the inside of the unit 2 Stop the air conditioner and disconnect power Remove the...

Page 13: ...relative humidity A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting 3 Low noise of the air condition...

Page 14: ...emperature If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 9 Auto restart function Power failure during operation will stop the...

Page 15: ...may have blown Battery in Remote controller may have been exhausted The time you have set with timer is incorrect Wait for power to be restored Check that plug is securely in wall receptacle Replace...

Page 16: ...MEMO Date of installation Purchased from Dealer Name Date of purchase Model number Serial number...

Page 17: ...ing from a faulty installation is specifically excluded This unit must be operated under conditions as recommended at voltages indicated on the unit Any attempts made to service or modify the unit by...

Reviews: