background image

    Install indoor unit

 

 

NOTE:

 

 

Where the electric cable length is not long enough, replace with another that is long 
enough as joints on the cables are not to be avoided. Ensure the replacement cable 
is of the same quality and diameter.

 

 

 

The  electric  wiring  must  be  correctly  connected,  wrong  connection  may  cause  spare 
parts malfunction. 

 

 

 

Tighten the terminal screw. 

 

 

 

After tightening the screw, slight pull the wire to confirm it is firm. 

 

 

 

Wrong connection of earth wire may cause electric shock. 

 

 

 

The cover plate must be reinstalled, otherwise shock, dust and moisture may cause fire, 

electric shock or unit malfunction.

 

 

 

 

Install the indoor unit

 

 

 

The  piping  can  be  lead  out  from  right,  right  rear, 

left left rear. 

 

 

1.

When routing the piping and wiring from the left or 

right side of indoor unit, cut off the tailings from 
the chassis necessary(Show in Fig.7)

 

Cut off the tailings 1 when routing the wiring only;

 

Cut off the tailings 1 and tailings 2 when routing

 

both the wiring and piping.

 

 

2.

Gently route the piping from the body case, wrap 
the piping, electric wire, water pipe with tape and 
pull them through the piping hole (As show in 
Fig.8)

 

3.

Hang the mounting slots of the indoor unit on the 

upper tabs of the rear panel and check if it is firm 
enough.(As show in Fig.9)

 

4.

The height of the installed location should be 2.5m 

or more from the floor.

 

 

 

 

 

Left

 

 
 

 

 

 

 

 

 

Install the connection pipe

 

 

 

1.

Align the center of the piping flare with the relevant valve.

 

 

 

2.

Screw in the flare nut by hand and then tighten the

 

 

 

 

nut with spanner and torque wrench refer to the

 

 

 

 

following:

 

 

 

 

Indoor unit piping

 

 

 

Taper nut Piping

 

 

Hex nut diameter

 

Tightening torque

(N·m)

 

 

 

 

Ф

6

 

15~20

 

 

 

 

  Ф 

9.52

 

31~35

 

 

 

 

Spanner

 

 

Ф

 

12

 

50~55

 

 

Torque

 

 

Ф 

16

 

60~65

 

 

wrench

 

 

 

 

 

 

 

 

NOTE: Firstly connect the connection pipe to indoor unit, then to outdoor unit; pay attention to the piping 
bending, do not damage the connection pipe; the joint nut must not be over-tightened, otherwise it may 
cause leakage. The above table provides the tightening torque required.

 

 

21

 

 

 

Ф 

19             70~75

 

Summary of Contents for ECO1216SD

Page 1: ...ister your air conditioner Model information can be found on the CE label Please register your product online at www ecoair org For your future convenience record the model information below _________...

Page 2: ...are present Any maintenance on the air conditioner must only be carried out after disconnecting from the electric mains supply Any repairs must be carried out by a suitably qualified engineer Ensure t...

Page 3: ...and must be connected to the terminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or colour...

Page 4: ...r operation 1 Notices for use 3 Names and functions of each part 5 Operation of remote wireless control 6 Emergency operation 11 Clean and care 12 Troubleshooting 14 Installation service Notices for i...

Page 5: ...the air intake or outlet Keep combustible spray away doors open for a long time vents of both the outdoor and indoor from the units more than 1m while operating the air conditioner units It can decrea...

Page 6: ...r of left right direction Louver of upward downward direction Don t insert your hands or stick into the air Don t blow the wind to animals and plants intake or outlet vents directly It can cause a bad...

Page 7: ...You may need to use alternative heating equipment Defrosting When outdoor temperature is low but high humidity frost will form on outdoor unit that will affect the heating resulting in the auto defro...

Page 8: ...ide DB WB o C Outdoor side DB WB o C Maximum cooling 32 23 48 21 15 Minimum cooling 10 Maximum heating 27 24 18 Minimum heating 20 15 The operating temperature range outdoor temperature for cooling un...

Page 9: ...Indoor unit Air in Air out Wireless remote control Cool Dry Heat Power ON OFF Receive window 1 Power cable 2 Remote Control 3 Front panel 4 Filter 5 Guide louver Outdoor unit 6 Wall pipe Air in 7 Bin...

Page 10: ...button Press this button to power on and off This clears the timer or sleeping function previously set MODE Mode button Press this button the running mode will change as follows AUTO COOL DRY FAN HEAT...

Page 11: ...fan speed TIMER Whilst unit is on you may press this button to set timer off Whilst unit is off you may press this button to set timer on Press this key once the words Hour on off will appear and flic...

Page 12: ......

Page 13: ...Guide for operation optional operation 1 Press SLEEP button set the sleep mode 2 Press TIMER button then press button to set the scheduled timer on or timer off 3 Press light button to control displa...

Page 14: ...sly to switch C and F Changing batteries and notices 1 Slightly to press the place with along the arrowhead direction to push the back cover of wireless remote control As show in figure 2 Take out the...

Page 15: ...ressing this button In which case the display indicator light will be off if the AC receives this signal Emergency operation If the wireless remote control is lost or broken please use the manual swit...

Page 16: ...re are microcomputer components and circuit diagrams on the front panel Clean the air filter Recommended once every three months NOTE In dusty environment more frequent cleaning will be required After...

Page 17: ...the installation stand of the outdoor unit is damaged or not If damaged please contact your installer Maintain after use Turn main power off Clean the filter clean the indoor and outdoor units panels...

Page 18: ...g the filter If problem persists obtain a maintenance service from your installer Sound of water flow can be heard during The air conditioner is started when it is the operation running the compressor...

Page 19: ...insert it Is it in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged...

Page 20: ...tion will occur In dehumidifying mode indoor fan will stop in order to avoid condensed water to be vaporized again The air delivery is delayed during this action If unit is running in high humidity co...

Page 21: ...h as hot spring zones where a sulfured gas is generated Indoor Unit Installation Position Selection 1 The air inlet and outlet vent should be far from any obstruction make sure that air is well ventil...

Page 22: ...2 Don t drag the power cable emphatically 3 It must be earthed and it should be connected to the special earth device operated by a qualified electrician The air switch must have the functions of magn...

Page 23: ...outlet side Space to the floor The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures Space to the wall Abo...

Page 24: ...e hole to prevent the connection piping and wiring from being damaged when passing through the hole Install the water drainage pipe 1 The drain hose should be placed at a downward slant otherwise the...

Page 25: ...ing only Cut off the tailings 1 and tailings 2 when routing both the wiring and piping 2 Gently route the piping from the body case wrap the piping electric wire water pipe with tape and pull them thr...

Page 26: ...be tightly shut 2 Connect joint of charging hose to vacuum pump 3 Fully open handle handle of Lo manifold valve 4 Open the vacuum pump to evacuate At the beginning slightly loosen joint nut of low pr...

Page 27: ...city It may cause condensation and dripping It may cause condensation and dripping It may cause electric malfunction or damage the part It may cause electric malfunction or damage the part It may caus...

Page 28: ...r Fig c Fig d Cleaning and Maintenance Take out the healthy filter before cleaning and reinstall it after cleaning according to the installation instruction Pay special attention to that silver ion fi...

Page 29: ...ghtly from the illustration This warranty is in addition to and does not affect your statutory rights For after sales needs please visit www ecoair org service or email technical ecoair org or contact...

Reviews: