Install indoor unit
Install the rear panel
1.Always mount the rear panel horizontally. The outlet of water tray should be adjusted slightly downward
when installing to enable gravity flow of condensation externally.
2.Fix the rear panel on the wall with screws.
.
.
.
.
(Where is pre-covered with plastic granula)
.
.
.
.
3.Be sure that the rear panel has been fixed
.
firmly enough to withstand the weight of an
.
adult of 60kg, further more, the weight should
be evenly shared by each screw.
.
.
Φ
φ
.
.
.
Install the piping hole
1. Make the piping hole (Ф55) in the wall at a slight downward slant to
the outdoor side.
2.Insert the piping-hole sleeve into the hole to prevent the connection piping
and wiring from being damaged when passing through the hole.
Install the water drainage pipe
1. The drain hose should be placed at a downward slant otherwise the water will fail
to drain outward causing leakage from the indoor unit
2.Do not wrench or bend the drain hose or flood its end with water
Connect indoor and outdoor electric wires
1.Open the surface panel.
2.Remove the wiring cover .
3.Route the power connection cord and signal control wire (for cooling and heating unit only) from
the back of the indoor unit and pull it toward the front through the wiring hole for connection.
4.Connect the interconnection cord to the terminal block, and then fix the cord with cord anchorage.
5.Reassemble the clamp and wiring cover.
6.Recover the surface panel.