background image

 

14 

Warranty and Disclaimers 

 
 
 

WARRANTY 

 
The products described in this manual, with the exception of the UEGO sensor, are warranted 
to be free from defects in material and workmanship for a period of one year from the date of 
shipment to the buyer.  Within the one year warranty period, we shall at our option replace 
such items or reimburse the customer the original price of such items which are returned to us 
with shipping charges prepaid and which are determined by us to be defective.  This warranty 
does  not  apply  to  any  item  which  has  been  subjected  to  misuse,  negligence  or  accident;  or 
misapplied; or modified; or improperly installed. 
 
The  UEGO  sensor  is  considered  an  expendable  part  and  as  such  cannot  be  covered  by  a 
warranty.   
 
This  warranty  comprises  the  sole  and  entire  warranty  pertaining  to  the  items  provided 
hereunder.    Seller  makes  no  other  warranty,  guarantee,  or  representation  of  any  kind 
whatsoever.  All other warranties, including but not limited to merchantability and fitness for 
purpose, whether express, implied, or arising by operation of law, trade usage, or course of 
dealing are hereby disclaimed. 
 
The warranty is void if the control module is opened or the wiring harness is modified. 
 

LIMITATION OF REMEDY 

 
Seller's  liability  arising  from  or  in  any  way  connected  with  the  items  sold  and/or  services 
provided shall be limited exclusively to repair or replacement of the items sold or refund of 
the purchase price paid by buyer, at seller's sole option.  In no event shall seller be liable for 
any incidental, consequential or special damages of any kind or nature whatsoever, including 
but  not  limited  to  lost  profits  arising  from  or  in  any  way  connected  with  items  sold  and/or 
services  provided  to  buyer,  whether  alleged  to  arise  from  breach  of  contract,  express  or 
implied warranty, or in tort, including without limitation, negligence, failure to warn or strict 
liability.  In no event shall the company's liability to buyer arising out of or relating to the sale 
of  any  product  or  service  exceed the purchase price paid by buyer to the company for such 
product or service. 
 
 

PRODUCT CHANGES 

 
We reserve the right to discontinue a particular product or to make technical design changes 
at any time without notice. 
 

Summary of Contents for F/A1000

Page 1: ...F A1000 F A1500 Fuel Air Ratio Monitor Instruction Manual 02 06 Part Number 1001A 6...

Page 2: ...al may be photocopied or reproduced in any form without prior written consent from ECM ENGINE CONTROL AND MONITORING Information and specifications subject to change without notice F A1000 and F A1500...

Page 3: ...put 4 SMB Interface Serial Measurement Bus F A1500 Only 5 Simulated O2 Sensor EGO Output 7 Calibration 8 Fuel Type Compensation 8 Pressure Compensation 8 Specifications and Limits 10 Measurement Range...

Page 4: ...ii Supplementary Information 15...

Page 5: ...cquisition or engine control systems SMB Serial Measurement Bus Interface on F A1500 Simulated O2 sensor output 11 to 28 VDC operation2 F A Monitor Components List The following items are included wit...

Page 6: ...cause permanent sensor damage 4 Do not put the UEGO sensor in a heavily sooting or oil burning engine 5 Use of the UEGO sensor with leaded fuels over time may reduce the sensitivity of the sensor 6 D...

Page 7: ...eads Install the UEGO sensor by lightly coating its threads with a non lead containing antiseize compound and tighten it to 30 3 ft lbf 40 4 Nm Attach the sensor to the wiring harness and route the ha...

Page 8: ...e sure that all condensed water is out of the tailpipe before the tailpipe probe is inserted into the exhaust Analog Output The F A Monitor has a 0V to 5V linearized output suitable for input into a d...

Page 9: ...the two SMB connectors on the F A1500 Cable part number 1500A 16 connects the PC to the SMB PC port of any one of the F A1500 modules i e it does not have to be the module with address 0 and subsequen...

Page 10: ...Byte 10 Dh 16 bit Ip Low Byte Eh N A F A1500 Status Code See table below Fh N A PWR Green LED ERR Red LED FLASH CODE STATUS CODE CONDITION ON OFF 0 Data valid Sensor OK OFF 1 1 Sensor not connected or...

Page 11: ...n to 1V rich signal that switches at Lambda 1 0 This is the same switch point as the production O2 sensor The simulated O2 sensor output is available at the short black wire near the blue connector of...

Page 12: ...o of 1 85 and an O C ratio of zero If a fuel of a different composition is used Equation 2 can be used to compensate i e correct the F A Monitor s output F Acorr m 16p 12 2 368 x m 2p 4 x F Ameas Equa...

Page 13: ...measured B x P 1 B x P Equation 3b where Lambda corrected the Lambda corrected for exhaust pressure Lambda measured the Lambda output by the F A B 0 000627 for Lambda 1 0 rich B 0 000830 for Lambda 1...

Page 14: ...size is identical to that of most O2 sensors used in production vehicles Output Specifications and Limits Analog Output 0V at 0 125 F A gasoline 5V at 0 055 F A gasoline F A 0 014 x Vout 0 125 Output...

Page 15: ...erminal Assignments F A1500 Only Cable from PC to SMB PC Port on F A1500 Module 6ft P N 1500A 16 DB9 Female to PC Terminal Number DB9 Male to Module Terminal Number 2 Rx 1 3 Tx 2 5 Gnd 6 SMB PC Cable...

Page 16: ...e unit is being confused by noisy power or operating in an electrically noisy environment In some situations a timing light might create a noise problem Keeping the control module and its wiring harne...

Page 17: ...unning engine When installing the F A Monitor s cabling and sensor on a stopped engine it is best to think out your moves before you make them Route and cable tie all cables away from hot moving sharp...

Page 18: ...express implied or arising by operation of law trade usage or course of dealing are hereby disclaimed The warranty is void if the control module is opened or the wiring harness is modified LIMITATION...

Page 19: ...15...

Page 20: ...16...

Page 21: ...17...

Page 22: ...18...

Page 23: ...19 State Diagram for SMB Communication...

Page 24: ...20...

Page 25: ......

Page 26: ...Los Altos CA 94023 0040 USA 408 734 3433 Fax 408 734 3432 www ecm co com...

Reviews: