Eclipse RatioAir v1 Design Guide No. 115, 11/12/2008

Step 4:

 

Ignition System 

(Continued)

Ignition Gas Piping

RatioAirs are capable of ignition with either low fire or bypass start 

gas.

Low Fire Start:

Bypass Start Gas (Optional):

An optional fuel orifice meter connected in the start gas piping can 

simplify start-up and adjustment. To start the burner at the lowest 

possible gas input, select a fuel orifice meter for 5" to 10" w.c. 

pressure drop when the gas flow is at the burner’s rated low fire.
The flame monitoring control system consists of two main 

components:

Flame Sensor

• 

Flame Monitoring Control

• 

Flame Sensor

Two types can be used on a RatioAir Burner:

Flame Rod

• 

UV scanner

• 

Flame rods are available on model RA0025, RA0040, RA0075 

and RA0100 burners with alloy or SiC tubes. A flame rod can also 

be used on RA0200 burners but with upright left hand piping or 

inverted right hand piping configurations only. Further information 

can be found in:

Info Guide 832

• 

A UV scanner can be used on all RatioAir Burner sizes. Further 

information can be found in:

Info Guide 852; 90° UV scanner

• 

Info Guide 854; straight UV scanner

• 

Instruction Manual 855; solid state UV/IR scanner

• 

Info Guide 856; self-check UV scanner

• 

Main gas

shut-off

valve train

Main gas

shut-off

valve train

NC

Optional fuel orifice meter recommended.

NC

Step 5:

 

Flame Monitoring

Control System

Flame Rod

UV Scanner

Summary of Contents for RA Series

Page 1: ...Eclipse RatioAir Burners RA Series Version 1 Design Guide 115 11 12 2008...

Page 2: ...sed or implied We have made every effort to make this manual as accurate and complete as possible Should you find errors or omissions please bring them to our attention so that we may correct them In...

Page 3: ...ign Guide No 115 This document Datasheet Series 115 Available for individual RA models Required to complete design and selection Installation Guide No 115 Used with Datasheet to complete installation...

Page 4: ...Act with great care and follow the instructions Warning Indicates hazards or unsafe practices which could result in severe personal injury or damage Act with great care and follow the instructions Ca...

Page 5: ...lities 7 Operator Training 7 Replacement Parts 7 System Design 8 Design 8 Step 1 Burner Option Selection 9 Step 2 Blower Option Selection 11 Step 3 Control Methodology 11 Step 4 Ignition System 12 Ste...

Page 6: ...ower and an air gas ratio regulator to fire over a wide gas turndown range with controlled ratio Available with three different outlet tube velocity characteristics standard medium and high velocity R...

Page 7: ...sign purpose Do not deviate from any instructions or application limits described herein without written advice from Eclipse Read the entire manual before attempting to start this system If you do not...

Page 8: ...on Gas Pipe Connection Flame Supervision Air Flow Switch Blower Option Selection Including 2 Power Supply Frequency Pressure and Flow Blower Motor Type Blower Inlet Motor Orientation Control Methodolo...

Page 9: ...and clean without corrosives Combustion Air Temperature Changes in air supply temperature can affect the burner capacity The combustion air supply temperature should not exceed 250 F Fuel Type Variati...

Page 10: ...lator are threaded using the customer selected pipe thread option The high turndown option includes a ratio regulator with an adjustment for lower inputs Flame Supervision Determine if a flame rod or...

Page 11: ...e limitations cleanliness requirements of the process Motor Orientation All RatioAirs are assembled with a right hand blower motor orientation All standard RatioAirs are designed for air gas ratio con...

Page 12: ...under certain circumstances RatioAirs are capable of direct spark ignition at higher gas inputs Most local safety codes and insurance requirements limit the maximum trial for ignition time the time i...

Page 13: ...itoring Control Flame Sensor Two types can be used on a RatioAir Burner Flame Rod UV scanner Flame rods are available on model RA0025 RA0040 RA0075 and RA0100 burners with alloy or SiC tubes A flame r...

Page 14: ...cted during trial for ignition Component Selection Eclipse can help in the design of a main gas shut off valve train that satisfies the customer and complies with all local safety standards and codes...

Page 15: ...ter mm inch in 3 94 x 10 2 MJ m normal BTU ft standard 2 491 x 10 2 Metric to English From To Multiply By kiloPascals kPa millibar mbar 10 meter m millimeter mm 1000 millibar mbar kiloPascals kPa 0 1...

Page 16: ...y burners 760 Fuel Orifice Meter Fuel orifice meters are used to measure gas flow 910 Adjustable Limiting Orifice Adjustable limiting orifices are used for fine adjustment of gas flow Pressure Regulat...

Page 17: ...Offered By Burnerparts com 2011 Williamsburg Road Richmond Virginia 23231 Phone 804 236 3881 Fax 804 236 3882 www burnerparts com...

Reviews: