No Type & Description
11 Alarm
Abort
This output type activates when the user disarms the system
after an alarm and within the “Abort Delay” period.
12 Fire
Alarm
This output type activates when a fire alarm is generated.
13 PA
Alarm
This output type activates when a panic alarm is generated.
14 Duress
Alarm
This output type activates when a duress alarm is generated.
15 24hr
Alarm
This output type activates when a 24hr alarm is generated.
16 Medical
Alarm
This output type activates when a medical alarm is generated.
17 Tamper
Alarm
This output type activates when a tamper alarm is generated.
18 Ready
This output type activates when the system is ready for arming,
i.e. all zones are healthy.
19 Trouble
This output type activates when a trouble alarm is generated.
20 Alert
This output type activates when an alert event is generated and
deactivates when the user has acknowledged the alert.
21 Zone
Bypass
This output type activates when one or more zones are
bypassed.
22
In Walk Test
This output type activates when the user walk test mode is
selected.
23
Flash 1 Second
This output type continually pulses on and off at a rate of 1
second.
24
User Test Active
This output type activates when the user test mode is selected in
the “Bell Test” menu.
25 PSTN
Fault
This output type activates when a fault is detected on the PSTN
connected to the control panel.
26
PSTN Off Hook
This output type activates when an off-hook condition is
detected on the PSTN connected to the control panel.
27 PSTN
Ringing
This output type activates when ringing is detected on the PSTN
connected to the control panel.
28 Battery
Fault
This output type activates when a fault is detected with the
control panel standby battery.
29
Box Tamper Fault
This output type activates when the control panel box tamper is
open.
30
Bell Tamper Fault
This output type activates when the control panel bell tamper is
open.
31 Engineer
on
Site
This output type activates when the engineer is logged on.
32 Detector
Reset
This output type is normally active and is used for powering
devices that require their power supply to be removed in order to
reset them. The output deactivates for 5 seconds at the start of
exit mode and when the system is reset.
33 Detector
Latch
This output type is used to latch the alarm condition on
detection devices that have a latch input.
34 System
Low
Volts
This output type activates when a low voltage fault is detected
with the control panel standby battery.
No Type & Description
35 In
Exit
This output type activates when the system is in exit mode.
36 In
Entry
This output type activates when the system is in entry mode.
37
In Second Entry
This output type activates when the system is in second entry
mode.
38 In
Alarm
This output type activates when any alarm is generated.
39 Auxiliary
Alarm
This output type activates when an auxiliary alarm is generated.
40 Warning
Alarm
This output type activates when a warning alarm is generated.
41 Keypads
Locked
This output type activates when a security key is active.
42 Output
Fault
This output type activates when a fault is detected on one of the
monitored control panel outputs.
43 Call
Engineer
This output type activates when the system requires an engineer
access code in order to reset the system.
44 Device
Fault
This output type activates when a device fault is detected.
45 Service
Required
This output type activates when the service timer expires.
46 Cleaner
Bypassed
This output type activates when a “Cleaner Bypass” is invoked.
47 2-Wire
Smoke
This output type is specifically designed for use with “Panel
Output 5”, when connecting 2-Wire Smoke Sensors.
48
2-Wire Smoke Alarm
This output type activates when a 2-Wire smoke alarm is
generated.
49
2-Wire Smoke Fault
This output type activates when a 2-Wire smoke fault is
generated.
50 Door
Access
This output type activates for 30 seconds when any valid user
code is entered.
51 Alarm
Test
This output type activates when the user select the alarm
sounder test.
52
Panel AC On
This output type activates when the mains supply is present.
Group 02: Control Timer
The EC-P10 has 5 control timers each timer can be assigned to
an output:
No Type & Description
01
Control Timer 1
This output type activates when Control Timer 1 is on and
deactivates when Control Timer 1 is off.
02-
05
Control Timer 2 - 5
As Control Timer 1.
Group 03: Remote Control
There are 5 remote controlled outputs, which can be assigned to
an output:
No Type & Description
01 Remote
Control
1
This output type is switched on and off via the
UDL
software,
smart phone app and via a touch tone telephone.
02-
05
Remote Control 2 - 5
As Remote Control 1.