Appendix

Design Guide 540 3/9/2009

Conversion Factors

Metric to English

Metric to Metric

English to Metric

From

To

Multiply By

cubic meter (m³)

cubic foot (ft³)

35.31

cubic meter/hr (m³/h)

cubic foot/hr (cfh)

35.31

degrees Celsius (°C)

degrees Fahrenheit (°F)

(°C x 9/5) + 32

kilogram (kg)

pound (lb)

2.205

kilowatt (kW)

BTU/hr

3414

meter (m)

foot (ft)

3.28

millibar (mbar)

inches water column ("w.c.)

0.401

millibar (mbar)

pounds/sq in (psi)

14.5 x 10

-3

millimeter (mm)

inch (in)

3.94 x 10

-2

MJ/Nm³ 

BTU/ft³ (standard)

2.491 x 10

-2

From

To

Multiply By

kiloPascals (kPa)

millibar (mbar)

10

meter (m)

millimeter (mm)

1000

millibar (mbar)

kiloPascals (kPa)

0.1

millimeter (mm)

meter (m)

0.001

From

To

Multiply By

BTU/hr

kilowatt (kW)

0.293 x 10

-3

cubic foot (ft3)

cubic meter (m3)

2.832 x 10

-2

cubic foot/hour (cfh)

cubic meter/hour (m3/h)

2.832 x 10

-2

degrees Fahrenheit (°F)

degrees Celsius (°C)

(°F - 32) ÷ 5/9

foot (ft)

meter (m)

0.3048

inch (in)

millimeter (mm)

25.4

inches water column ("w.c.)

millibar (mbar)

2.49

pound (lb)

kilogram (kg)

0.454

pounds/sq in (psi)

millibar (mbar)

68.95

BTU/ft³ (standard)

MJ/Nm³

40.14

Summary of Contents for 300 MA

Page 1: ...Eclipse Extern A Therm Recuperators Models 300 MA 2500 MA Design Guide 540 3 9 2009...

Page 2: ...duct whether due to breach of warranty negligence strict liability or otherwise is limited to the furnishing of replacement parts and Eclipse will not be liable for any other injury loss damage or exp...

Page 3: ...5 Safety Warnings 5 Capabilities 5 Operator Training 5 Replacement Parts 5 System Design 6 Furnace Temperature Limits 6 Flue Gas Restrictions 6 Recuperator Sizing 7 Dilution Air 7 Number of Recuperat...

Page 4: ...ease of installation and efficient use of existing pipe work The housings are internally insulated there is no need for additional external insulation Figure 1 1 Extern A Therm Recuperator Audience Th...

Page 5: ...ribed herein without written advice from Eclipse Capabilities Adjustment maintenance and troubleshooting of the mechanical and the electrical parts of this system should be done by qualified personnel...

Page 6: ...ld destroy the recuperator A high temperature protection limit switch must be fitted to ensure flue temperatures do not exceed 2100 F The recuperator must be positioned so that it will not be exposed...

Page 7: ...w is controlled on the cold side of the recuperator All the subsequent instructions and descriptions are written with this assumption If it is required that a single Extern A Therm recuperator will pr...

Page 8: ...lling the air and gas can be found in Design Guide 206 covering ThermJet Burners for Preheated Combustion Air Eductor Air Flow Eductors are designed to overcome the exhaust gas pressure drop through t...

Page 9: ...ical Piping for Greater Furnace Pressure Control Eductor Air Combustion Air Dilution Air if Required Exhaust Gas Preheated Combustion Air to Burners Preheated Combustion Air to Burners Eductor Air Com...

Page 10: ...5 x 10 3 millimeter mm inch in 3 94 x 10 2 MJ Nm BTU ft standard 2 491 x 10 2 From To Multiply By kiloPascals kPa millibar mbar 10 meter m millimeter mm 1000 millibar mbar kiloPascals kPa 0 1 millime...

Page 11: ...Offered By Power Equipment Company 2011 Williamsburg Road Richmond Virginia 23231 Phone 804 236 3800 Fax 804 236 3882 www peconet com...

Reviews: