Eclipse Magnetics Micromag HP/50NPT Operating Instructions Manual Download Page 6

11

10

If operated and cleaned correctly your Micromag HP/50NPT will give many years of trouble 
free filtration with no consumable parts. The filter will remove even the smallest particle due 
to its high magnetic field strength. Cleaning should take no more 
than a few minutes.

• 

Turn off the fluid flow

• 

Isolate and relieve any line pressure

• 

Release the bowl using the spanner supplied

• 

Take the magnetic core out of the housing and move away to a 
suitable cleaning area. Insert the cleaning post into the opposite 
end of the core to the slots and using the cleaning tool wipe the contamination clear 
away from the slots over the post

• 

Re-assemble the magnet core into the body and re-fit the body

• 

Check the condition of the lid seal and replace if damaged. Turn on the material flow. 
After each clean the housing should be wiped over to avoid the build up of excessive 
dirt/dust

Do not use corrosive substances to clean the equipment

6 Maintenance

6.1  General notes

• 

Keep the system clean, especially the magnetic cores 

• 

Regular check of the seal for defects

• 

Regular check of the housing and the magnetic core surface for wear

• 

Do not clean with aggressive cleaner!

7  Spare parts/service

7.1  Spare parts list

Pos.

Terms

Part No.

1

Magnetic core 5

MM5/MC/HT

2

Magnetic core 10

MM10/MC/HT

3

Magnetic core 20

MM20/MC/HT

4

Lid Seal ‘O’ ring Dia. 100 × 4 section 
viton

Dia. 100 × 4 section viton

5

Core seal ‘O’ ring

Dia. 40 × 3 section viton

6

Cleaning post

MM/CP

7

Cleaning tool

MM/CTS

7.2    Service address

Manufacturer

Eclipse Magnetics Ltd

Atlas Way
Sheffield
S4 7QQ
England

T

 +44(0)114 225 0600

F

 +44(0)114 225 0525

[email protected]
www.eclipsemagnetics.com

Summary of Contents for Micromag HP/50NPT

Page 1: ...to ensure the accuracy of the information in this publication please note that specifications may change without notice Eclipse Tools North America Inc 442 Millen Road Unit 9 Stoney Creek ON L8E 6H2...

Page 2: ...si 50 bar max line pressure DO NOT USE IN EXPLOSIVE ATMOSPHERE UNLESS ORDERED AS AN ATEX APPROVED PRODUCT 1 2 Used symbols Important notes Danger notes Safety notes Contents 1 Introduction 1 1 Range o...

Page 3: ...llons minute MM10 HP 50NPT 26 gallons minute MM20 HP 50NPT 40 gallons minute Vessel Aluminium Magnetic characteristics max operating temperature NdFeB HT material 302 F Port size and contamination cap...

Page 4: ...ove the specific operating temperature 2 NO oscillating vibrations 3 NO impacts 4 NO strong external magnetic flux fields 5 Pay attention to the cleaning and maintenance of the system 4 2 General prev...

Page 5: ...to be installed as follows Before installation ensure that all supplies are isolated Micromag HP 50NPT is to be installed vertically with the bowl pointing upwards this allows fluid to drain out of t...

Page 6: ...id seal and replace if damaged Turn on the material flow After each clean the housing should be wiped over to avoid the build up of excessive dirt dust Do not use corrosive substances to clean the equ...

Page 7: ...the goods is not exceeded IATA Dangerous Medium Prescript Cap 3 9 1 1 Magnetised Material ICAO Instructions Packing Instruction 902 Permanent Magnets where possible should have keeper bars installed...