11
10
If operated and cleaned correctly your Micromag HP/50NPT will give many years of trouble
free filtration with no consumable parts. The filter will remove even the smallest particle due
to its high magnetic field strength. Cleaning should take no more
than a few minutes.
•
Turn off the fluid flow
•
Isolate and relieve any line pressure
•
Release the bowl using the spanner supplied
•
Take the magnetic core out of the housing and move away to a
suitable cleaning area. Insert the cleaning post into the opposite
end of the core to the slots and using the cleaning tool wipe the contamination clear
away from the slots over the post
•
Re-assemble the magnet core into the body and re-fit the body
•
Check the condition of the lid seal and replace if damaged. Turn on the material flow.
After each clean the housing should be wiped over to avoid the build up of excessive
dirt/dust
Do not use corrosive substances to clean the equipment
6 Maintenance
6.1 General notes
•
Keep the system clean, especially the magnetic cores
•
Regular check of the seal for defects
•
Regular check of the housing and the magnetic core surface for wear
•
Do not clean with aggressive cleaner!
7 Spare parts/service
7.1 Spare parts list
Pos.
Terms
Part No.
1
Magnetic core 5
”
MM5/MC/HT
2
Magnetic core 10
”
MM10/MC/HT
3
Magnetic core 20
”
MM20/MC/HT
4
Lid Seal ‘O’ ring Dia. 100 × 4 section
viton
Dia. 100 × 4 section viton
5
Core seal ‘O’ ring
Dia. 40 × 3 section viton
6
Cleaning post
MM/CP
7
Cleaning tool
MM/CTS
7.2 Service address
Manufacturer
Eclipse Magnetics Ltd
Atlas Way
Sheffield
S4 7QQ
England
T
+44(0)114 225 0600
F
+44(0)114 225 0525
[email protected]
www.eclipsemagnetics.com