  Do not perform the treatment on anyone with cancer.  

  Do not perform the treatment directly over the hepatic region. 

  Do not perform the treatment directly over the renal region. 

  Do not perform the treatment directly on the neck or on the face. 

  Do not perform the treatment directly on osseous areas. 

 

The  operator  must  be  sure  that  the  conditions  descriptive  above  do  not  exist  before 
proceeding with any application on the person. 

Keep away from children. 

Do not expose the equipment to dust, humidity or temperatures below 15°C.  

The equipment must only be used by personal trained to use it and who have been informed on 
the warnings mentioned above. 

After every use of the equipment, disconnect the power cable. 

When the device is not in use, it must be protected from unauthorized use. 

Do  not  deform,  fold,  step  on  or  knot  the  power  cable  or  any  of  the  cables  connected  to  the 
equipment. 

Replace the cables as soon as any signs of deterioration appear and only with original pieces. 

Do not block the air vents in the back or the bottom of the unit. 

Do not place containers containing liquid on the equipment. 

The  manufacture  will  not  be  held  responsible  for  any  use  of  the  equipment  different  from  that 
which it is intended. 

The use of commands, controls or procedure sequences that are not indicated in this manual can 
produce damage by explosion or radiation. 

The  equipment  should  not  be  used  connected  to  an  electrical  power  network  that  does  not 
comply  with  the  current  regulation  of  that  county  or  to  an  electrical  line  that  does  not  have  a 
ground connection that is inefficient. 

2.3 PRECAUTIONS 

This equipment should be used exclusively by operators properly trained in the use of cavitation 
equipment and only after reading this manual completely. 

The  information  provided  in  this  section  does  not  aim  at  covering  all  the  problems  and/or 
prevailing against the knowledge of an experienced operator. 

Although  it  is  not  easy  to  specify  the  effects  cavitation  will  have  on  each  person,  the  following 
points should be kept in mind. 

1)  The  specific  effect  depends  on  the  power  level,  the  type  of  impulse,  the  RANGE,  the 

RATE and naturally the type of tissue. 

2)  Cavitation can cause some discomfort if not used properly.  
3)  For  this  reason,  precautions  must  be  taken,  such  as  a  correct  evaluation  of  the  tissue 

during the treatment. 

4)  Beginning with low power levels is the best way to deeply evaluate the cavitation capacity. 

Summary of Contents for CAVIX

Page 1: ...can it be reproduced multiplied or published through any electronic data processing form The information contained in this manual may be modified or broaden without previous notification without it r...

Page 2: ...ALLATION AND SET UP 9 4 1 UNPACKING 9 4 2 POSITIONING 9 4 3 REVISION 9 5 OPERATION 9 6 TREATMENTS 11 6 1 BEFORE STARTING THE TREATMENT 11 6 2 GENERAL PRECAUTIONS 11 6 3 CONTRAINDICATIONS 11 6 4 COMPLI...

Page 3: ...RIS will not assume any liability for damages that may occur if the device is used without following the instructions and or ignoring the following advice Keep the device out of children reach Do not...

Page 4: ...permanent review If the system is sold or donated the user manual must be deliver with the device If by any of the following Inadequate use of the equipment Failure to use the instruction manual Bad m...

Page 5: ...ng liquid on the equipment The manufacture will not be held responsible for any use of the equipment different from that which it is intended The use of commands controls or procedure sequences that a...

Page 6: ...e to a surgical treatment of the localized fatty layers Furthermore thanks to the synchronization system CAVIX ensures a calibrated frequency of ultrasound emission guaranteeing a safe treatment respe...

Page 7: ...t upon the fatty tissue 3 3 INTENDED USER The equipment is intended to be used by dermatologists or beauticians with specific training in the technique of cavitation 3 4 COMPONENTS The CAVIX includes...

Page 8: ...INMANUUIN185 Rev 2019 04 01 ENG 3 Applicator connector 4 Pedal connector 5 Power cable conenector with fuse holder 6 Power switch 7 Air vent CAVITATION APPLICATOR CAVITATION APPLICATOR SUPPORT FOOTSW...

Page 9: ...n or if it is on turn it off immediately and consult one of our authorized assistance centers 4 3 REVISION Once the installation is complete and before turning on the CAVIX we recommend carrying out t...

Page 10: ...the RANGE value respectively the indicator 2 will show the programmed value This value indicates the range of frequencies emitted only when the SWEEP mode is ON The range of emitted ultrasound freque...

Page 11: ...xclusively by operators properly trained in the use of cavitation equipment and only after reading this manual completely The information provided in this section does not aim at covering all the prob...

Page 12: ...ld communicate the sensations experimented and the variations of these sensations To be explicit this is not a treatment with definite results because that would depend on eating habits and possible c...

Page 13: ...ns Periodic cleaning of all external components Clean applicators Check connections Annual technical verification of the equipment For any type of maintenance work or revision contact your local distr...

Page 14: ...aving a spare fuse on hand 1 Disconnect the power cable from the electric current and from the device 2 Under the connector for the power cable there is a small rectangular plastic piece where the fus...

Page 15: ...ing The output selected is incorrect or the intensity is too low Select the correct output pressing the button 8 on the front panel Check the programmed intensity Defective applicator Check the estate...

Page 16: ...CAVIX has passed our Quality Control and no defects have been found in its manufacture therefore guarantees proper working order under adequate conditions that are indicated in this manual The guaran...

Reviews: