CAVITATION APPLICATOR 

Clean applicator after every session.  

Disconnect the applicator before cleaning. 

To clean use cotton or a cloth dampened in alcohol, to eliminate any product residue.  

Do not use detergents, solvents or other abrasive agents. 

Do not soak the applicator for cleaning since it could affect its normal working condition. 

8.2 ELECTRICAL CONNECTIONS 

Permanently check the condition of all the components and their ageing process.  

Check that there are no: 

 

Cables in bad conditions; cut or torn.  

 

Bad connection of the cable with the socket. 

 

Rusty pins in the connectors. 

8.3 CHANGING THE FUSE 

To avoid a waste of time for unavailability of the CAVIX we recommend having a spare fuse on 
hand. 

1)  Disconnect the power cable from the electric current and from the device. 
2)  Under the connector for the power cable there is a small rectangular plastic piece where 

the fuses are held. Using a screwdriver and pressing a little, remove the lid to replace the 
damaged fuse.  

3)  Remove the damaged fuse and replace it with the spare fuse in the same socket. Use only 

T4AL250V fuses. 

4) 

To close the socket, press till there is a “click” sound. 

5)  Connect the power cable. 

9.  TECHNICAL SPECIFICATIONS 

Maximum power emission 

3 Watts/cm2 

Emission frequency 

from 36 to 44 KHz 

Operation mode 

Continuous and Pulsed 

Power supply 

100 - 240 V 

Nº of phases 

1 (single phase) 

Frequency 

50 - 60 Hz 

Grade of water protection 

IPX0 

Power consumption 

120W 

Fuses 

T4A250V 

Applicator 

Corporal 

Cooling system 

Air (interior forced) 

Dimensions 

367  x  300  x  145  mm  (Width  x  Height  x 
Length) 

Weight 

5,86 Kg (without accessories) 

Operating conditions   

10 - 40 ºC  

Summary of Contents for CAVIX

Page 1: ...can it be reproduced multiplied or published through any electronic data processing form The information contained in this manual may be modified or broaden without previous notification without it r...

Page 2: ...ALLATION AND SET UP 9 4 1 UNPACKING 9 4 2 POSITIONING 9 4 3 REVISION 9 5 OPERATION 9 6 TREATMENTS 11 6 1 BEFORE STARTING THE TREATMENT 11 6 2 GENERAL PRECAUTIONS 11 6 3 CONTRAINDICATIONS 11 6 4 COMPLI...

Page 3: ...RIS will not assume any liability for damages that may occur if the device is used without following the instructions and or ignoring the following advice Keep the device out of children reach Do not...

Page 4: ...permanent review If the system is sold or donated the user manual must be deliver with the device If by any of the following Inadequate use of the equipment Failure to use the instruction manual Bad m...

Page 5: ...ng liquid on the equipment The manufacture will not be held responsible for any use of the equipment different from that which it is intended The use of commands controls or procedure sequences that a...

Page 6: ...e to a surgical treatment of the localized fatty layers Furthermore thanks to the synchronization system CAVIX ensures a calibrated frequency of ultrasound emission guaranteeing a safe treatment respe...

Page 7: ...t upon the fatty tissue 3 3 INTENDED USER The equipment is intended to be used by dermatologists or beauticians with specific training in the technique of cavitation 3 4 COMPONENTS The CAVIX includes...

Page 8: ...INMANUUIN185 Rev 2019 04 01 ENG 3 Applicator connector 4 Pedal connector 5 Power cable conenector with fuse holder 6 Power switch 7 Air vent CAVITATION APPLICATOR CAVITATION APPLICATOR SUPPORT FOOTSW...

Page 9: ...n or if it is on turn it off immediately and consult one of our authorized assistance centers 4 3 REVISION Once the installation is complete and before turning on the CAVIX we recommend carrying out t...

Page 10: ...the RANGE value respectively the indicator 2 will show the programmed value This value indicates the range of frequencies emitted only when the SWEEP mode is ON The range of emitted ultrasound freque...

Page 11: ...xclusively by operators properly trained in the use of cavitation equipment and only after reading this manual completely The information provided in this section does not aim at covering all the prob...

Page 12: ...ld communicate the sensations experimented and the variations of these sensations To be explicit this is not a treatment with definite results because that would depend on eating habits and possible c...

Page 13: ...ns Periodic cleaning of all external components Clean applicators Check connections Annual technical verification of the equipment For any type of maintenance work or revision contact your local distr...

Page 14: ...aving a spare fuse on hand 1 Disconnect the power cable from the electric current and from the device 2 Under the connector for the power cable there is a small rectangular plastic piece where the fus...

Page 15: ...ing The output selected is incorrect or the intensity is too low Select the correct output pressing the button 8 on the front panel Check the programmed intensity Defective applicator Check the estate...

Page 16: ...CAVIX has passed our Quality Control and no defects have been found in its manufacture therefore guarantees proper working order under adequate conditions that are indicated in this manual The guaran...

Reviews: