background image

 

24 

6.2. Technical characteristics   

 

6.2. Características técnicas 

6.2. Caractéristiques techniques 

 

6.2. Technische daten 

 
 
 
 

 LPA6000 

LPA10000 

LPA16000 

POWER 20-20kHz 1% THD 

 

 

 

4

 

Stereo 

320 WRMS 

500 WRMS 

760 WRMS 

8

 Stereo 

210 WRMS 

330 WRMS 

450 WRMS 

8

 Bridged 

640 WRMS 

1000 WRMS 

1520 WRMS 

 

 

 

 

Frequency response (-1dB/-3dB) 

10Hz/58kHz 10Hz/58kHz 10Hz/52kHz 

Crossover filter (-3dB) (CH1=LOW, CH2=HIGH) 

150Hz/18dB oct. 

 

 

 

 

THD+Noise @ 1kHz Full Pwr. 

<0.1% 

<0.05% 

<0.1% 

 

 

 

 

S+N/N 20Hz-20kHz @ 1W/4

 

>85dB 

Damping factor 1kHz @ 8

 

>270 

Slew Rate 

±37V/µs 

±43V/µs 

±30V/µs 

 

 

 

 

Input connectors 

XLR3 & ¼” Jack balanced & RCA 

 

 

 

 

Gain / Impedance 

26/32dB/20k

 Bal. 10k

 Unbal 

 

 

 

 

Signal present indicator 

-40dB 

 

 

 

 

Output connectors 

Speakon & Binding Posts 

 

 

 

 

Mains 230V 

50/60Hz. 

Power consumption (pink noise, 1/8 power @ 4ohm) 

670VA 

1040VA 

600VA 

Power consumption (pink noise, 1/3 power @ 4ohm) 

1000VA 

1580VA 

1840VA 

 

 

 

 

Dimensions 482.6x304x88mm 482.6x360x88mm 482.6x360x88mm 
 

 

Weight 5.62kg 

6.85kg 

9.2kg 

 

Summary of Contents for LPA6000

Page 1: ...USER MANUAL MANUAL DE INSTRUCCIONES NOTICE D EMPLOI BEDIENUNGSANLEITUNG...

Page 2: ......

Page 3: ...cuit 06 3 6 Output connections 06 4 OPERATION AND USAGE 06 4 1 Start up 06 4 2 Input attenuators 06 4 3 Indicators 07 5 CLEANING 07 6 DIAGRAMS 23 6 1 Connection diagram 23 6 2 Technical characteristic...

Page 4: ...ls are 2 rack units high and are based on a robust chassis Thanks to their oversize power supply the amplifiers can work comfortably at loads of 4 The LPAs include balanced inputs via XLR3 connectors...

Page 5: ...E THE FUSE WITH ANOTHER ONE WITH A HIGHER VALUE The mains cables must not be near the shielded cables carrying the audio signal as this could cause humming 3 3 Input signal connections The input conne...

Page 6: ...onnected to the amplifier operating in BRIDGE mode is not lower than 8 ATTENTION Terminals 1 and 1 should only be used in case of STEREO or PARALLEL mode and terminals 2 and 2 in BRIDGED mode Any othe...

Page 7: ...al support service CLIP indicators 3 They light up when the amplified signal present in the amplifier output is just below the level of clipping or saturation This system always provides a true indica...

Page 8: ...23 6 DIAGRAMS 6 DIAGRAMAS 6 SCH MAS 6 DIAGRAMME 6 1 Connection diagram 6 1 Diagrama de conexi n 6 1 Sch ma de connexion 6 1 Anschlu diagramm...

Page 9: ...filter 3dB CH1 LOW CH2 HIGH 150Hz 18dB oct THD Noise 1kHz Full Pwr 0 1 0 05 0 1 S N N 20Hz 20kHz 1W 4 85dB Damping factor 1kHz 8 270 Slew Rate 37V s 43V s 30V s Input connectors XLR3 Jack balanced RC...

Page 10: ...25 6 3 Block diagram 6 3 Diagrama de bloques 6 3 Blocs de diagrammes 6 3 Blockschatbild...

Page 11: ...voces 19 Fuse holder 19 Portafusible 20 Mains socket except LPA16000 20 Base de red excepto LPA16000 6 4 Liste de fonctions 6 4 Funktionsliste 1 Att nuateurs d entr e 1 Eingangsregler 2 Indicateur de...

Page 12: ...27 6 5 Function diagram 6 5 Diagrama de funciones 6 5 Sch ma de fonctionnement 6 5 Funktions bersicht...

Page 13: ...ECLER Laboratorio de electro ac stica S A Motors 166 168 08038 Barcelona Spain INTERNET http www ecler com E mail info ecler es 50 0228 01 00...

Reviews: