background image

 

1. IMPORTANT NOTE 
 
 

Congratulations! You are the owner of a carefully designed and manufactured equipment. We thank you for 

trusting on us and choosing our amplifier LPA. 
 

In order to obtain maximum operativity and perfect functioning order, it is most important to carefully read all 

considerations taken into account in this manual before connecting this amplifier. 
 

We recommend our authorised Technical Services if any maintenance task should be needed so that 

optimum operation shall be achieved. 
 
1.1. Precautions 
 

The amplifier should have an earth connection in good conditions (earth resistance, Rg=30

 or 

less). 
The environment must be dry and dustless. 
Do not expose the unit to rain or water splashes, and do not place liquid containers or 
incandescent objects like candles on top of the unit. 

Do not obstruct the ventilation shafts with any kind of material. 
In case there is some type of intervention and/or connection-disconnection of the amplifier, it is most 

important to previously disconnect the mains power supply. 

Do not manipulate the output terminals to the loudspeakers when the amplifier is switched on, there are 

voltages up to 200Vpp. 

The output cabling should be connected by a qualified technician. Otherwise only use pre-made flexible 

cables. 

There are no user or serviceable parts inside the amplifier. 

 
 
2. INTRODUCTION 
 

The LPA range of amplifiers offers the classical and acknowledged professional reliability of Ecler 

amplifiers with a new aesthetic style and at an affordable price. The range consists of 3 stereo models of 320, 500 
and 760W RMS per channel over 4

. All models are 2 rack units high and are based on a robust chassis. Thanks 

to their oversize power supply, the amplifiers can work comfortably at loads of 4 

The LPAs include balanced inputs via XLR3 connectors and a ¼” jack, and non-balanced inputs via RCA 

connectors. Their outputs offer complete versatility, thanks to the dual format used: connectors of the safety 
terminal type with a normalized distance and Speakon

®

 connectors. They also include an electronic limiter system 

to prevent clipping due to signal saturation, and a practical cut filter or switchable crossover, which permits a single 
amplifier to provide the low and high signals of a two-way mono loudspeaker system (with one LPA amplifier on 
each channel for a stereo configuration). 
 
2.1. Main features: 
 

• 

Efficient system of progressive ventilation with a flow adaptable to the internal temperature of the amplifier. 
Air is taken in at the rear and throws it out at the front panel 

• 

The rotary input attenuation controls are easily accessible on the front panel. 

• 

Indicators for power-on and standby indicators (POWER ON, STBY), signal presence (SIGNAL), clipping 
(CLIP), operating mode (BRIDGE), crossover activation (XOVER) and activation of protections 
(PROTECT). 

• 

Efficient system of protections against short-circuits, overheating and the presence of a continuous signal, 
to prevent damage to the amplifier itself and/or to the loudspeakers connected to it. 

• 

Integrated anticlip circuit

 

(clipping or saturation of the signal) which is permanently activated. 

• 

Operating mode selector: STEREO, PARALLEL and BRIDGE. 

• 

Input sensitivity selector. 

• 

Symmetrical inputs via XLR3 connectors, and ¼” jack type. Asymmetrical inputs via RCA connectors. 

• 

Outputs amplified with terminal-type connectors and Speakon

®

 connectors. 

• 

Operation at 8 and 4

, or 8

 in bridge mode. 

• 

Warranty: 2 years. 

Summary of Contents for LPA6000

Page 1: ...USER MANUAL MANUAL DE INSTRUCCIONES NOTICE D EMPLOI BEDIENUNGSANLEITUNG...

Page 2: ......

Page 3: ...cuit 06 3 6 Output connections 06 4 OPERATION AND USAGE 06 4 1 Start up 06 4 2 Input attenuators 06 4 3 Indicators 07 5 CLEANING 07 6 DIAGRAMS 23 6 1 Connection diagram 23 6 2 Technical characteristic...

Page 4: ...ls are 2 rack units high and are based on a robust chassis Thanks to their oversize power supply the amplifiers can work comfortably at loads of 4 The LPAs include balanced inputs via XLR3 connectors...

Page 5: ...E THE FUSE WITH ANOTHER ONE WITH A HIGHER VALUE The mains cables must not be near the shielded cables carrying the audio signal as this could cause humming 3 3 Input signal connections The input conne...

Page 6: ...onnected to the amplifier operating in BRIDGE mode is not lower than 8 ATTENTION Terminals 1 and 1 should only be used in case of STEREO or PARALLEL mode and terminals 2 and 2 in BRIDGED mode Any othe...

Page 7: ...al support service CLIP indicators 3 They light up when the amplified signal present in the amplifier output is just below the level of clipping or saturation This system always provides a true indica...

Page 8: ...23 6 DIAGRAMS 6 DIAGRAMAS 6 SCH MAS 6 DIAGRAMME 6 1 Connection diagram 6 1 Diagrama de conexi n 6 1 Sch ma de connexion 6 1 Anschlu diagramm...

Page 9: ...filter 3dB CH1 LOW CH2 HIGH 150Hz 18dB oct THD Noise 1kHz Full Pwr 0 1 0 05 0 1 S N N 20Hz 20kHz 1W 4 85dB Damping factor 1kHz 8 270 Slew Rate 37V s 43V s 30V s Input connectors XLR3 Jack balanced RC...

Page 10: ...25 6 3 Block diagram 6 3 Diagrama de bloques 6 3 Blocs de diagrammes 6 3 Blockschatbild...

Page 11: ...voces 19 Fuse holder 19 Portafusible 20 Mains socket except LPA16000 20 Base de red excepto LPA16000 6 4 Liste de fonctions 6 4 Funktionsliste 1 Att nuateurs d entr e 1 Eingangsregler 2 Indicateur de...

Page 12: ...27 6 5 Function diagram 6 5 Diagrama de funciones 6 5 Sch ma de fonctionnement 6 5 Funktions bersicht...

Page 13: ...ECLER Laboratorio de electro ac stica S A Motors 166 168 08038 Barcelona Spain INTERNET http www ecler com E mail info ecler es 50 0228 01 00...

Reviews: