Ecler HADA Series User Manual Download Page 9

 
 

 

PRE

CA
U

TIO

N

PA

CK
A

G

E CO
NT
ENT

D

ES

CRI
PT

IO

 &

 

FEA
TU

R

ES

 

PA

NE
L F

U

NCT

O

N

INS
TA

LL

 &

 CO
NN
ECT

 

STA
R

T-

UP
 &

 O

PE

R

ATI
O

N

 
TEC

H

N

IC

A

D

A

TA

 

W

AR
R

AN
TY

 &

 

EN

V

IRO
NME

NT
 

6.

 

Mute indicator LED

: lights up in white colour when the amplified output is muted. 

7.

 

Prot. indicator LED

: lights up in red colour when any protection of the power module is 

active (along with the mute LEDs of the channels that are failing), or when the standby 
mode is active (along with the ON LED). 

8.

 

Thermal indicator LED:

 lights up in red colour when temperature limiter is activated. 

9.

 

Ext. Mute LED

: lights up in white colour when the external mute is active. 

10.

 

Data indicator LED

: lights up in white colour to indicate that the software HADA DSP 

Manager is online. 

11.

 

On indicator LED

: in white colour indicates power energy activity. 

 

 

 

5.2

 

Rear Panel 

 

 

 

1.

 

Mains socket base 

2.

 

Power switch 

3.

 

External mute port 

4.

 

Amplified outputs, OUT 1-4, 2-pin Euroblock 

5.

 

Remote Volume ports REMOTE 1-4, 6-pin Euroblock 

6.

 

Analogue inputs, IN 1-4, 3-pin Euroblock, balanced. 

7.

 

Reset button 

8.

 

RJ-45 ethernet network port, NET, RJ-45 

 

 

 

Summary of Contents for HADA Series

Page 1: ...DA SERIES EN HADA Series NETWORKABLE AMPLIFIERS Digital Amplifiers USER MANUAL PRECAUTIONS PACKAGE CONTENTS DESCRIPTION FEATURES PANEL FUNCTONS INSTALL CONNECT START UP OPERATION TECHNICAL DATA WARRAN...

Page 2: ...NECT 10 6 1 Location Assembly and Ventilation 10 6 2 Mains Connection 11 6 3 Analogue Input Connections 12 6 4 Amplified Output Connections 13 6 4 1 Out Configurations 13 6 5 Remote Volume 14 6 5 1 Co...

Page 3: ...GE CONTENTS DESCRIPTION FEATURES PANEL FUNCTONS INSTALL CONNECT START UP OPERATION TECHNICAL DATA WARRANTY ENVIRONMENT 8 2 1 HADA 4B150 35 8 2 2 HADA 4B250 36 8 2 3 HADA 4B400 37 8 2 4 HADA 4B500 38 8...

Page 4: ...intenance servicing for which instructions may be found in the literature accompanying the appliance WARNING If applicable The terminals marked with symbol may be of sufficient magnitude to pose a ris...

Page 5: ...g lightening sorts or when unused for long periods of time 13 Refer all servicing to qualified personnel Servicing is required when the device has been damaged in any way such as power supply cord or...

Page 6: ...Services All ECLER products are covered by warranty please refer to www ecler com or the warranty card included with this product for the period of validity and conditions Ecler is truly committed wit...

Page 7: ...ctionality includes a matrix mixer for selecting which input channels to allocate to the outputs Processing includes 10 band EQ HP and LP filters limiters multi band compressors delay up to 2 sec and...

Page 8: ...e one taking control of the bridged channel pair and 2 or 4 will be then inactive For further information see HADA DSP Manager chapter The front panel knobs can be disabled by holding down the ON butt...

Page 9: ...th the ON LED 8 Thermal indicator LED lights up in red colour when temperature limiter is activated 9 Ext Mute LED lights up in white colour when the external mute is active 10 Data indicator LED ligh...

Page 10: ...previously set the volume gain controls to minimum level Always use shielded cables to make connections between devices In an amplifier avoid placing the speaker output cables close to other signal c...

Page 11: ...any country in the world On the rear panel there is an on off switch for the unit In the front panel there is the button ON with its LED indicator that illuminates when the unit is in operation To en...

Page 12: ...inputs The selection of hardware inputs and their routing and mixing towards either amplifier channel is performed from its embedded web application For further information please refer to HADA DSP Ma...

Page 13: ...hannels Please connect the loudspeakers as reported on the silkscreens when HiZ mode or Bridge mode is required Make sure to match the impedance of the total load connected to the loudspeakers when wo...

Page 14: ...combination with front potentiometers the potentiometer set at the lower value between the two is the one that defines the maximum output level 6 5 1 Connecting the REMOTE VOL Control Ports The REMOT...

Page 15: ...stron Extron AMX Vity Medialon etc registered trademarks by their manufacturers using the third party TCP IP control embedded in HADA devices Refer to the Telnet Control chapter for more information 6...

Page 16: ...te the device is operational To enter in standby mode press and hold the ON button until all LEDs on the front panel blink once The prot LED red will illuminate together with the ON LED white to indic...

Page 17: ...server as in standard networks the HADA network interface will take a random address in the 169 254 x y class If your PC s network card is also configured in DHCP mode through the automatic discovery...

Page 18: ...idge Mono mode is set connect the loudspeakers line at 100V or 70V as indicated below The Positive pin of the output in bridge mode is the left one When channel 1 and 2 are set as bridge the input con...

Page 19: ...ADA DSP Manager and update the firmware again with the correct firmware of each HADA model When the unit is in this special state all the front LEDs of the unit Prot Thermal Ext Mute Data and ON will...

Page 20: ...PUT POWER all channels driven 1 THD Max output power 8 125W Max output power 4 Max output power 8 bridge mode 125W 250W Max output power 100V 250W Bridge Mode Max output power 70V 250W Bridge Mode SIG...

Page 21: ...x4 GPIs 0 3 3V 5 pin Euroblock connector rear panel External MUTE Yes dry contact 2 pins Euroblock connector rear panel Euroblock pitch 3 5 mm LOCAL CONTROL Attenuators Front panel knobs Defaults Amp...

Page 22: ...DSP Manager Others Preset management 4x4 Matrix Mixer Settings via HADA DSP Manager PHYSICAL Operating temperature Min 0 C 32 F Max 40 C 104 F performance may be reduced above 40 C Operating humidity...

Page 23: ...Max output power 100V 500W Bridge Mode Max output power 70V 500W Bridge Mode SIGNAL Voltage gain 30 to 37 dBV 32 2 to 39 2 dBu Input sensitivity 12 to 12 dBV 9 8 to 14 2 dBu 0 25 to 3 98 Vrms Nominal...

Page 24: ...h 3 5 mm LOCAL CONTROL Attenuators Front panel knobs Defaults Amplified OUTs attenuators Output mode settings Lo Z Hi Z 70V 100V 4 8 Output mode selection per couple of channels Software RUN SLEEP mod...

Page 25: ...4 Matrix Mixer Settings via HADA DSP Manager PHYSICAL Operating temperature Min 0 C 32 F Max 40 C 104 F performance may be reduced above 40 C Operating humidity 5 85 RH non condensing Storage temperat...

Page 26: ...Max output power 100V 800W Bridge mode Max output power 70V 800W Bridge Mode SIGNAL Voltage gain 31 to 38 dBV 33 2 to 40 2 dBu Input sensitivity 12 to 12 dBV 9 8 to 14 2 dBu 0 25 to 3 98 Vrms Nominal...

Page 27: ...h 3 5 mm LOCAL CONTROL Attenuators Front panel knobs Defaults Amplified OUTs attenuators Output mode settings Lo Z Hi Z 70V 100V 4 8 Output mode selection per couple of channels Software RUN SLEEP mod...

Page 28: ...4 Matrix Mixer Settings via HADA DSP Manager PHYSICAL Operating temperature Min 0 C 32 F Max 40 C 104 F performance may be reduced above 40 C Operating humidity 5 80 RH non condensing Storage temperat...

Page 29: ...Max output power 100V 1000W Bridge mode Max output power 70V 1000W Bridge mode SIGNAL Voltage gain 31 to 37 dBV 33 2 to 39 2 dBu Input sensitivity 12 to 12 dBV 9 8 to 14 2 dBu 0 25 to 3 98 Vrms Nomina...

Page 30: ...h 3 5 mm LOCAL CONTROL Attenuators Front panel knobs Defaults Amplified OUTs attenuators Output mode settings Lo Z Hi Z 70V 100V 4 8 Output mode selection per couple of channels Software RUN SLEEP mod...

Page 31: ...Matrix Mixer Settings via HADA DSP Manager PHYSICAL Operating temperature Min 0 C 32 F Max 40 C 104 F performance may be reduced above 40 C Operating humidity 5 80 RH non condensing Storage temperatu...

Page 32: ...output power 100V 1500W Bridge Mode Max output power 70V 1500W Bridge Mode SIGNAL Voltage gain 31 to 38 dBV 33 2 to 40 2 dBu Input sensitivity 12 to 12 dBV 9 8 to 14 2 dBu 0 25 to 3 98 Vrms Nominal po...

Page 33: ...h 3 5 mm LOCAL CONTROL Attenuators Front panel knobs Defaults Amplified OUTs attenuators Output mode settings Lo Z Hi Z 70V 100V 4 8 Output mode selection per couple of channels Software RUN SLEEP mod...

Page 34: ...Matrix Mixer Settings via HADA DSP Manager PHYSICAL Operating temperature Min 0 C 32 F Max 40 C 104 F performance may be reduced above 40 C Operating humidity 5 80 RH non condensing Storage temperatu...

Page 35: ...ES PANEL FUNCTONS INSTALL CONNECT START UP OPERATION TECHNICAL DATA WARRANTY ENVIRONMENT 8 2 Mechanical Diagrams 8 2 1 HADA 4B150 482 6 286 5 30 4 281 5 88 www ecler com 61 1116 0100 Ecler HADA 4B150...

Page 36: ...IPTION FEATURES PANEL FUNCTONS INSTALL CONNECT START UP OPERATION TECHNICAL DATA WARRANTY ENVIRONMENT 8 2 2 HADA 4B250 88 286 5 4 30 281 5 482 6 www ecler com 61 1117 0100 Ecler HADA 4B250 Mechanical...

Page 37: ...IPTION FEATURES PANEL FUNCTONS INSTALL CONNECT START UP OPERATION TECHNICAL DATA WARRANTY ENVIRONMENT 8 2 3 HADA 4B400 88 286 5 4 30 281 5 482 6 www ecler com 61 1118 0100 Ecler HADA 4B400 Mechanical...

Page 38: ...TION FEATURES PANEL FUNCTONS INSTALL CONNECT START UP OPERATION TECHNICAL DATA WARRANTY ENVIRONMENT 8 2 4 HADA 4B500 ww w ecler com 61 1119 010 0 Ecler HADA 4B500 Mechanical Diagram All the mea surmen...

Page 39: ...RONMENT 8 2 5 HADA 4B750 ww w ecler com 61 1120 0100 Ecler HADA 4B750 Mechanical Diagram All the measurments are in mm 482 6 286 5 30 4 2 81 5 88 A t t ent i o n F or BR I D G E M ode chang e D SP Set...

Page 40: ...to production tolerances NEEC AUDIO BARCELONA S L reserves the right to make changes or improvements in the design or manufacturing that may affect these product specifications For technical queries c...

Reviews: