6
4. OPERATION AND USAGE
4.1. Start up
Start up the eCA120 by connecting the equipment to an external power source to which the
DC
24V
connector of the eCA120 has already been connected. The LED indicator
ON/STBY
immediately
lights up on the front panel. We recommend you turn on all the devices in the following order: sound
sources, mixer, equalisers, active filters and processors and, finally power amplifiers. Powering off
should be done by following the exact reverse sequence. Following this order, the introduced noise due
to turning on or switching off the devices will not affect those further on in the chain and will be inaudible.
Once turned on, the front volume control (VOLUME) and the controller connected to the
REMOTE port (if any) may be used to set the output volume of the signal amplified by the unit.
4.2. AUTO STANDBY Function
The
AUTO STANDBY
function (idle or low consumption mode) means you can install the eCA120
in inaccessible places and leave the device connected to the mains power supply permanently because
when no signal is detected, it automatically goes into standby mode, saving energy.
To enable the
AUTO STANDBY
mode, the jumper labeled "AUTO STBY" on the front panel has to
be in the ON position. When it is enabled and after 2 minutes or more without any audio signal at the audio
input of the device (or a very weak signal, lower than the activation threshold), the eCA120 will
automatically switch into standby mode, lighting up the amber
ON/STBY
LED located on the front panel of
the device. When a valid audio signal is detected in any of the inputs, the eCA120 leaves standby mode
and starts operating normally again and the
ON/STBY
LED goes green.
When enabling the
AUTO STANDBY
mode with the front panel jumper (
ON
position), one of the 2
following assumptions may occur:
a) There is NO audio signal in the inputs. Result: the amplifier immediately goes into AUTO
STANDBY mode
b) There is an audio signal in the inputs. Result: the amplifier stays active
4.3. LED indicators
•
SP
: The signal presence or
SP
LED indicator shows that there is a signal in the amplifier
input. This lights up when the input level reaches the established detection threshold.
•
CLIP
: The saturation or
CLlP
LED indicator comes on when the signal delivered to the
speakers is close to the amplifier's clipping or saturation level. Input signals should be set to
ensure the
CLIP
(saturation or cut off) indicators never stay on, but that they do so at most to
the beat of the lowest sound frequencies. Otherwise the amplified signal will be distorted with
low quality and low intelligibility.
Note:
If the input signal is too high, the CLIP indicator lighting up very frequently over a
short time interval (a few seconds), the amplifier may go into protection mode, being muted to
return to normal operation in a short time
•
ON/STBY
: the green light comes on when the equipment is in normal operating mode and it
goes orange when it is in standby or low consumption mode (STANDBY).
4.4. Setup jumpers
•
REMOTE
:
REMOTE
: enables (ON) the remote volume control from a WPm-type wall panel (or
another model of the WPm series) connected to the REMOTE port.
•
AUTO STANDBY
: Switch the AUTO STANDBY function on (ON) or off. When the function is
on, the eCA120 will automatically go into STANDBY or low consumption mode in the absence
of audio signals in its inputs.