Maintenance
XDM-300
Installation
and
Maintenance Manual
4-16 ECI
Telecom
Ltd.
Proprietary
417006-2311-0H3-A00
Table
4-7: Troubleshooting procedures for optical OADM and Mux/DeMux
No. Symptoms
Probable
cause
Corrective
actions
1 Green
AC
indicator is
off.
Defective module
1.
Remove the module and wait a minute before
reinserting it. Make sure that you fully insert the
module in its slot.
2.
If the AC indicator does not turn on after reinsertion,
replace the module.
2 Red
FL
indicator does
not turn off
after software
download (this
occurs after
power-on and
resetting).
Defective module
1.
Remove the module and wait a few minutes before
reinserting it to reset. Make sure the AC indicator turns
on after the module is reinserted.
2.
The FL indicator must flash while software is
downloaded to the component. Wait until the software
download ends and check that the FL indicator turns
off.
3.
If the FL indicator turns on again, replace the module.
Table
4-8: Troubleshooting procedures for EISMs
No. Symptoms
Probable
cause
Corrective
actions
1 Green
AC
indicator is
off.
Defective module
1.
Remove the module and wait a minute before reinserting
it. Make sure that you fully insert the card in its slot.
2.
If the AC indicator does not turn on after reinsertion,
replace the module.
2 Red
FL
indicator on
the module
does not turn
off after
software
download (this
occurs after
power-on and
resetting).
Defective module
1.
Remove the module and wait a few minutes before
reinserting it to reset. Make sure the AC indicator turns
on after the module is reinserted.
2.
The FL indicator must flash while software is
downloaded to the module. Wait until the software
download ends and check that the FL indicator turns off.
3.
If the FL indicator turns on again, replace the module.
3 Orange
(traffic
carrying)
indicator on
module is off.
Module not
configured to carry
traffic
Check with the management station operator whether the
module has already been configured and provisioned; if not,
ignore the state of the orange indicator.
4 Green
(link
state) indicator
of an Ethernet
optical port is
off.
Problem related to
port
1.
Check port configuration.
2.
Check connections to LAN.
3.
Make sure at least one LAN station is active.
4.
Replace optical transceiver of port.
5 Link
state
indicator of an
10/100BaseT
Ethernet port
is off.
Problem related to
port
1.
Check port configuration.
2.
Check connections to LAN.
3.
Make sure at least one LAN station is active.