Cablite® VR LED Lighting System Installation Manual Rev 2.1
Electronic Controls, Inc.
7073 North Atlantic Ave. Cape Canaveral, FL 32920
800-633-9788
P a g e
|
9
•
Pin 2 (IN-) is -12 or -24VDC input (BLACK Wire)
•
Pin 3 (OUT+) is + output for general power (AC present) Downlight String (RED Wire)
•
Pin 4 (OUT-) is – output for general power downlight string (BLACK Wire)
•
Pin 5 & 6 is for external potentiometer (customer provided) for brightness adjustment
•
Pin 7 (EM+) is + output for EMERGENCY downlight string (2 downlights) (RED wire)
•
Pin 8 (EM-) is – output for EMERGENCY downlight string (2 downlights) (Black wire)
•
Pin 9 & 10 (STBY) – is for external key switch that turns all downlights off when pin 9 & 10 are
closed. When closed EMERGENCY downlights will light only if AC power is lost.
•
Pin 11 (BAT+) + side connection to battery
•
Pin 12 (BAT-) – side connection to battery
•
Pin 13 is FAULT relay common
•
Pin 14 is Normally Closed contact of fault relay: Contacts open (between Common pin 13) when
there is a Battery Fault
•
Pin 15 is the Normally open contact of the fault relay: Contacts close (between Common pin 13)
when there is a battery fault.
Figure 3 - CabLite VR Emergency Board
6.4.2
CabLite Emergency Board LEDs
•
CHARGE – the charge LED blinks when the battery is charging and remains solid when battery
is fully charged.
•
FAULT – The fault LED lights when there is a problem with the battery. Wrong voltage or not
charging.
7
Installation
Be sure all power is turned off before starting installation.