When you see the “notepad” icon in the left-hand margin, the paragraph to its 
immediate right will be a special note.  Notes represent information that may make 
your work quicker and more efficient.  The word NOTE: in boldface will mark the 
beginning of the text. 

 
 

When you see the “exclamation point” icon in the left-hand margin the paragraph 
to its right will be a warning.  The information could prevent injury, loss of 
property, or even death in extreme cases.  Any waring in this document should be 
regarded as critical information that should be read in its entirety.  The word 
WARNING: in boldface will mark the beginning of the text

.  

 

5

 

Safety Information 

 
 

Know the safety hazards related to any procedure you are about to perform.  
Know what equipment has been specified for each specific contact and know 
what tools and materials you should plan to have available.  Before connecting 
electrical wiring, take precautions to prevent accidents from happening to 
yourself and others around you. 
 

ALWAYS CONSIDER SAFTY FIRST! 

 

Wear a hard hat when working in the hoist way.

 

 

Wear safety glasses or goggles when using power tools

 

 

Always wear protective gloves when installing or removing access covers, 

conduits, wireway or electrical devices.

 

 

When working on car canopy, always be aware of where the sides of the car are 

located.

 

 

Use properly grounded cords and power equipment (ground fault circuit 

interrupters). 

 

Make sure there are proper clearances in hoist way between the car and other 

devices.  Before connecting wiring, cover sharp edges to keep hands and arms 
from being cut. 

 

Always know where other people are and how the elevator wiring can affect 

their safety. 

 

Safety lock and tag out procedures are always required before performing and 

kind of service, repair, adjustment, lubrication or inspection of power equipment. 

 

To reduce the danger of electrical shock, always make sure electrical 

connections are secure.  Also make sure no bare wires are exposed after pulling 
cable. 

 

Use a circuit tester to be certain the circuit is not active before touching it. 

 

Summary of Contents for CabLite VR Series

Page 1: ...ELECTRONIC CONTROLS INC 7073 NORTH ATLANTIC AVE CAPE CANAVERAL FL 32920 WWW ECIAMERICA COM 800 633 9788 CabLite VR LED Lighting System Installation Manual REV 2 1 DATE 1 5 2018 MANUAL NUMBER 36 ...

Page 2: ...20 800 633 9788 www eciamerica com P a g e 2 REV DATE DESCRIPTION 0 1 2 1 2017 Preliminary Release 1 0 3 8 2017 Original Release 2 0 1 4 2018 Added 2 75 Can and 24 Volt option 2 1 1 5 2018 Added new logo and TUV symbol Removed the words option and basic from product names Cleaned up drawings and added optional external 10k pots ...

Page 3: ...nections 8 6 4 2 CabLite Emergency Board LEDs 9 7 Installation 9 7 1 Downlight Identification 10 7 2 VR2 25 Downlight Dimensions 10 7 3 VR2 75 Downlight Dimensions 11 7 4 Installation Diagram 11 7 5 CabLite VR w o Dimming Wiring Diagram 12 7 6 CabLite VR w Dimming Wiring Diagram 12 7 7 CabLite VR Basic w Dimming Emergency Wiring 13 8 LED Replacement 14 9 Trouble Shooting 15 9 1 One Light Does Not ...

Page 4: ...l Code ASMEA17 1 Safety code for Elevators and Escalators and the codes of the National Electrical Manufacturer s Association NEMA There may be local regulatory or government offices that can also help determine which codes and standards are necessary for safe installation and operation Equipment damage or serious injury to personnel can result from failure to follow all applicable codes and stand...

Page 5: ...uld plan to have available Before connecting electrical wiring take precautions to prevent accidents from happening to yourself and others around you ALWAYS CONSIDER SAFTY FIRST Wear a hard hat when working in the hoist way Wear safety glasses or goggles when using power tools Always wear protective gloves when installing or removing access covers conduits wireway or electrical devices When workin...

Page 6: ...CabLite VR2 75 In addition there are 3 options for the CabLite VR lighting system Lighting without dimming Lighting with dimming Lighting with dimming and emergency lighting 6 1 Downlights Each downlight is equipped with 2 connectors located on the top of the can for stringing up to 12 lights together See section 7 Installation for more detail The 2 connectors are interchangeable so it does not ma...

Page 7: ...ory wired in its own gang box All that is needed is to connect the prewired 8 cable to the first downlight and connect the BROWN LINE and BLUE NEUT wires to 120VAC Refer to Figure 8 CabLite VR with Dimming Wiring 6 3 1 Dimmer Board The Dimmer board Figure 2 Dimmer Board allows for setting the brightness level of the LED lighting using either the onboard potentiometer or an external customer provid...

Page 8: ...omes factory wired in its own gang box All that is needed is to connect the prewired 8 cables to the first downlight and first emergency downlight and connect the BROWN LINE and BLUE NEUT wires to 120VAC Dimming and emergency lighting is included with this version CabLite VR Brightness is controlled through the onboard potentiometer or an external 10k POT see Figure 9 CabLite VR w Dimming Emergenc...

Page 9: ...itch that turns all downlights off when pin 9 10 are closed When closed EMERGENCY downlights will light only if AC power is lost Pin 11 BAT side connection to battery Pin 12 BAT side connection to battery Pin 13 is FAULT relay common Pin 14 is Normally Closed contact of fault relay Contacts open between Common pin 13 when there is a Battery Fault Pin 15 is the Normally open contact of the fault re...

Page 10: ...ht and drill the ceiling panels according to the specifications for your downlight listed in sections 7 2 VR2 25 Downlight Dimensions and 7 3 VR2 75 Downlight Dimensions Be sure there is a minimum 1 clearance between the top of the downlight can and the cab top to accommodate the connectors See Figure 6 Installation example 7 1 Downlight Identification 7 2 VR2 25 Downlight Dimensions Figure 4 VR 2...

Page 11: ...ownlight Dimensions Figure 5 VR2 75 Downlight Dimensions 7 4 Installation Diagram A minimum of 1 inch clearance is required between the top of the can and top of car as shown in Figure 6 Installation example Be sure to leave a minimum 6 inch service loop at each downlight for inside cab access of LED assembly replacement Refer to section 8 LED Replacement Figure 6 Installation example ...

Page 12: ...iring Diagram AC IN line Brown wire on power supply AC IN neutral Blue wire on power supply DC OUT is RED wire of 8 cable DC OUT is BLACK wire of 8 cable Route the 8 cable to the first downlight and connect remaining downlights with 4 cables The two connectors on the downlights are interchangeable so cable connection does not matter Once wiring is complete and cover is on power supply box apply po...

Page 13: ...atter Apply power to lighting system and adjust brightness using the on board or external potentiometer See Figure 2 Dimmer Board When complete install cover 7 7 CabLite VR Basic w Dimming Emergency Wiring Figure 9 CabLite VR w Dimming Emergency Wiring As previously mentioned the CabLite system power supply and dimming board are pre wired from the factory The BATTERY negative terminal is prewired ...

Page 14: ...ry is fully charged Apply AC power to CabLite system All downlights should light Adjust the brightness of the downlights through the on board or external potentiometer See Figure 3 CabLite VR Emergency Board When complete replace cover Allow 24 hours for battery to fully charge 8 LED Replacement Insert the 10 torx into the center hole of the lens as shown in Figure 10 LED Removal to unscrew lens a...

Page 15: ... input i If 120VAC present replace power supply b If power output 12 or 24VDC is present replace 8 cable 9 3 Lights Do Not Turn On CabLite VR w Dimming and Dimming Emergency 1 Check connection between control board and first downlight 2 Using DVM measure between pins 3 and 4 OUT for correct DC voltage 12 or 24VDC a If correct voltage present replace 8 cable b If no output check for correct DC volt...

Page 16: ...sent check connections between battery and control board i NOTE that battery may not be fully charged b Check for correct Battery voltage and replace battery in necessary 9 5 Designated Emergency Lights Do Not Light with AC Power CabLite VR w Dimming and Emergency 1 Check connection between control board and first downlight a Replace cable if necessary 2 Check for correct voltage 12 or 24VDC at pi...

Reviews: